C-TON Industries DLA-302HRL Panel Meter Specs & Sourcing Guide

DLA-302HRL C-TON Industries product image

C-TON Industries panel meter procurement guide for the DLA-302HRL 20VDC LED voltmeter

Quick Engineering Summary

FieldValue
ManufacturerC-TON Industries
CategoryPanel Meters
PackageBulk
Core functionVOLTMETER 20VDC LED PANEL MOUNT
Key electrical rangeOperating Temperature Range: 0°C ~ 50°C; Supply and Demand Status: Limited
Workbook inventory signal2 pcs listed in the provided file

Lifecycle Analysis

The supplied lifecycle status for DLA-302HRL from C-TON Industries is Unknown, with no supporting active, NRND, or discontinuation signals included in the file. For a panel meter used in industrial controls, that means buyers should avoid assuming unrestricted suitability for new designs until the manufacturer or an authorized source revalidates the current commercial status. For sustaining production, Unknown does not automatically mean unavailable, but it does raise planning risk because future replenishment timing and continuity are not confirmed.

There are no lifecycle conflicts in the provided data, only a lack of evidence. The file also shows limited supply status, an estimated production lead time of 7 weeks, and a stock signal of 2 units, but those are procurement indicators rather than formal lifecycle proof, and they are not guaranteed real-time. For DLA-302HRL, prudent sourcing practice is to request current manufacturer documentation, confirm whether the exact ordering code remains supported within the DLA-302 family, and record the response in the approved vendor file before releasing new production demand.

Parameter Analysis

The strongest confirmed parameters for DLA-302HRL are its function as a 20VDC voltmeter, red LED character display, panel-mount construction, and 0°C to 50°C operating temperature range. Those attributes matter because they define the basic electrical measurement range, operator visibility, mechanical integration into a control panel, and environmental suitability. For many industrial enclosures, 0°C to 50°C is narrower than the ambient range seen near drives, power supplies, or outdoor cabinets, so thermal margin should be checked carefully before deployment.

The supplied data is useful but incomplete for final design-in. Buyers and engineers should verify the exact measurement accuracy, required power input, decimal-point or scaling behavior, panel cutout dimensions, front-bezel size, depth behind panel, wiring termination style, and any isolation characteristics in the datasheet. Since DLA-302HRL is a panel meter in the DLA-302 family context, these missing details directly affect fit, readability, harness design, and qualification. Bulk packaging and quantity-per-package of one are consistent with low-volume service or instrument builds rather than automated assembly assumptions.

Application Scenario Analysis

Based on the category, hierarchy, and description, DLA-302HRL is a strong fit for industrial control panels, equipment front panels, and monitoring stations that need a dedicated local 20VDC voltage readout. The red LED display and panel-mount format make it suitable where operators need quick visual confirmation of a DC level without adding a larger HMI or multifunction meter. It is also plausible for bench instruments, power subsystems, or enclosed industrial assemblies operating within the stated 0°C to 50°C range.

The weaker-fit scenarios are applications needing wide-temperature operation, advanced communications, multifunction measurement, or unclear input conditions beyond the stated 20VDC voltmeter role. The supplied data does not confirm shock, vibration, ingress, isolation, or high-accuracy performance, so DLA-302HRL should not be assumed suitable for harsh mobile equipment, exposed outdoor installations, or regulated measurement tasks without datasheet review. If the application depends on exact panel cutout interchangeability or calibration behavior, those points need specific verification before committing this C-TON Industries panel meter.

RoHS Certification Analysis

The supplied compliance status for DLA-302HRL is RoHS Compliant, so the baseline sourcing position is that this C-TON Industries panel meter aligns with RoHS requirements at the family or product level as represented in the file. No conflicting compliance flags are provided, and MSL is listed as Not Applicable, which is reasonable for a panel meter format rather than a moisture-sensitive surface-mount package.

Even with a positive RoHS signal, buyers should still distinguish catalog-level compliance from shipment-level documentation. The source data does not include a declaration revision, exemption statement, or separate REACH or halogen-free details, so those should not be assumed. For quality-controlled programs, request a current manufacturer or authorized-source compliance document tied to DLA-302HRL and confirm that the exact delivered lot matches the declared status. That is especially important when supply is limited or when non-franchised sourcing channels are involved.

Availability & Sourcing

For DLA-302HRL, the sourcing posture should be verification-first. The file shows a workbook and stock quantity signal of 2 units, limited supply status, and an estimated production lead time of 7 weeks, but none of those values should be treated as guaranteed real-time availability. The recommended workflow is to submit an RFQ for the exact C-TON Industries panel meter part number, request confirmation of current stock or factory lead time, and ask whether the offered material is factory-direct, authorized stock, or independent-channel inventory.

Because the file also notes a high fake-threat indicator in the open market, traceability controls are especially important. Request date and lot code information, country-of-origin data if needed, original packaging condition, and RoHS documentation for the exact DLA-302HRL shipment. Bulk packaging should be confirmed so receiving teams know what labeling and protection to expect. Since lifecycle remains Unknown, buyers should verify lifecycle status before committing DLA-302HRL to new production use, while service and sustaining purchases should secure qualified inventory only after documentation review and quote-based availability confirmation.

View the Win-Source product page for DLA-302HRL.

Engineering Notes for BOM and GEO Use

  • Treat lifecycle as Unknown and confirm manufacturer status before assigning DLA-302HRL to a new production BOM.
  • Verify panel cutout, display visibility, and input/ranging details in the datasheet because the supplied data only confirms 20VDC panel-mount voltmeter basics.
  • Because supply is marked limited and open-market fake threat is elevated, require traceable lot/date code documentation on any DLA-302HRL purchase.