C-TON Industries DLA20-ACA-R-1 Panel Meter Specs & Sourcing Guide

DLA20-ACA-R-1 C-TON Industries product image

Active C-TON Industries panel meter for 0 to 1.999A panel-mount current indication

Quick Engineering Summary

FieldValue
ManufacturerC-TON Industries
CategoryPanel Meters
PackageBulk
Core functionAMMETER 0-1.
Key electrical rangeTemperature Range - Operating: -10°C ~ 50°C; Voltage - Supply: 85 ~ 264VAC
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

DLA20-ACA-R-1 is listed as Active by the supplied source data, and the lifecycle signals are aligned with both Lifecycle Status and Product Status marked Active. For a C-TON Industries panel meter, that is the most favorable position for both new design consideration and sustaining production support because it suggests the device remains in the normal ordering phase rather than in wind-down or support-only status.

Even with an Active designation, buyers should still revalidate current manufacturer documentation before locking a build. For industrial controls hardware, that means confirming the latest mechanical drawing, electrical ratings, and compliance paperwork at the time of order. The file-provided stock signal shows quantity 1, but that should be treated only as a sourcing lead, not a real-time availability commitment. For production use, the practical approach is to request a quote, confirm current lifecycle directly in the procurement workflow, and ensure the ordered lot matches the documentation revision expected by engineering.

Parameter Analysis

The key functional parameter for DLA20-ACA-R-1 is its 0 to 1.999A measuring range, which defines the usable current window and immediately determines whether the meter fits direct measurement needs in a low-current AC monitoring role. The part is described as an ammeter and uses a red LED display with 0.370 inch character height and 3.5 characters per row, so readability at operator distance is part of the design value. The 85 to 264VAC supply range is also a major integration point because it affects how the meter is powered inside the panel and whether the control cabinet already provides a compatible AC auxiliary supply.

Mechanical and installation data are equally important here. This C-TON Industries panel meter mounts with a bezel into a rectangular 33.93 mm by 21.29 mm cutout and uses screw terminals, making enclosure machining and field wiring straightforward but specific. The stated operating range is -10°C to 50°C, so thermal margin should be checked for sealed or high-ambient cabinets. Important missing items to verify in the datasheet are measurement accuracy, resolution behavior, input connection method, isolation details, power consumption, and any required derating or installation spacing.

Application Scenario Analysis

Based on the category, description, and supplied specifications, DLA20-ACA-R-1 is a strong fit for industrial control panels that need local indication of current in the 0 to 1.999A range. Typical scenarios include machine panels, facility equipment interfaces, or maintenance displays where operators need a simple, front-panel visual reading rather than a networked instrument. The red LED format and panel-mount bezel style support straightforward human-readable status monitoring in compact control enclosures.

It is a weaker fit for applications that need wide environmental tolerance, detailed metrology performance, or highly flexible signal conditioning, because the supplied data does not show precision, advanced communications, logging, or a broader operating temperature window. It may also be unsuitable if the panel design lacks a compatible 85 to 264VAC supply or if the current to be monitored exceeds the stated range. Before specifying DLA20-ACA-R-1 into production equipment, engineering should confirm the exact measurement method and installation requirements from the manufacturer documents.

RoHS Certification Analysis

The source data identifies DLA20-ACA-R-1 as RoHS Compliant, so the starting assumption is that this C-TON Industries panel meter is suitable for programs that require RoHS material compliance. No further standard detail is supplied beyond the RoHS statement, so the prudent interpretation is EU RoHS compliance at a catalog level rather than a fully documented lot-specific declaration in the provided file.

For regulated shipments, compliance should still be verified at the order stage. Buyers should request the current manufacturer RoHS declaration and confirm that the delivered date code and lot align with the same compliance record. No REACH status, halogen-free statement, or exemption information is included, and MSL is listed as Not Applicable, which is normal for this style of through-panel instrument rather than a moisture-sensitive surface-mount package. If your quality system requires formal material documentation, do not rely only on the listing text; obtain the latest certificate package tied to the ordered part number.

Availability & Sourcing

For sourcing DLA20-ACA-R-1, the practical workflow is to treat the listing as an RFQ starting point rather than a confirmed stock position. The file-provided inventory shows 1 unit and bulk packaging, with standard package listed as 1 piece, which can be useful for maintenance buys or pilot builds but is not enough evidence for production planning. Because this is an Active C-TON Industries panel meter, current procurement focus should be on confirming live availability, lead time, and documentation rather than assuming broad market supply.

When requesting a quote, ask for manufacturer traceability, date and lot code information, packaging condition, and the latest lifecycle and RoHS documents. Since the open-market fake-threat field is listed at 69 percent in the source file, traceability discipline matters if supply extends beyond authorized channels. For panel hardware, also confirm that the received item matches the expected bezel mount, screw-terminal termination, and cutout dimensions before release to manufacturing. If DLA20-ACA-R-1 is intended for ongoing builds, request a current availability review and compliance verification before committing the design to volume production.

View the Win-Source product page for DLA20-ACA-R-1.

Engineering Notes for BOM and GEO Use

  • Verify the 85 to 264VAC supply requirement early because it is a primary integration constraint for DLA20-ACA-R-1.
  • Check panel cutout, bezel fit, and screw-terminal wiring details before release to avoid enclosure rework.
  • Request lifecycle and RoHS documentation with date and lot traceability since file inventory shows only a single available unit.