C-TON Industries DLA20-ACA5-3-AC1-B Panel Meter Specs & Sourcing Guide

DLA20-ACA5-3-AC1-B C-TON Industries product image

Active C-TON Industries panel meter for 0-100A AC-powered ammeter applications

Quick Engineering Summary

FieldValue
ManufacturerC-TON Industries
CategoryPanel Meters
PackageBulk
Core functionAMMETER 0-100A LED PANEL MOUNT
Key electrical rangeSupply and Demand Status: Shortage; Voltage - Supply: 85 ~ 264VAC
Workbook inventory signal2 pcs listed in the provided file

Lifecycle Analysis

DLA20-ACA5-3-AC1-B is listed as Active in the supplied C-TON Industries data, and the lifecycle signals are consistent with no stated conflict. For engineers, an Active panel meter generally means the part can still be considered for new designs, provided the latest manufacturer datasheet and ordering information are rechecked before design freeze. For sustaining production, the Active status reduces immediate obsolescence risk but does not remove the need for approved-vendor and documentation control.

The sourcing picture is slightly more cautious than the lifecycle label alone suggests. The file also indicates shortage status and only a very small file-provided quantity, which is useful as a lead signal but not a real-time stock guarantee. For DLA20-ACA5-3-AC1-B, procurement should confirm current factory availability, manufacturer lead-time exposure, and any recent product change notices. If this panel meter is being qualified into a long-life industrial build, revalidate the exact suffix, packaging, and compliance paperwork with C-TON Industries or authorized documentation channels before committing to production volume.

Parameter Analysis

The most decision-relevant attributes for DLA20-ACA5-3-AC1-B are its function as an ammeter, its 0 to 100A measuring range, its 85 to 264VAC supply, and its panel-mount mechanical format. The broad AC supply range is helpful for industrial control panels that may see different mains standards, while the screw-terminal interface supports serviceable field wiring. The blue LED display, 3.5-character format, and 0.370 inch character height are practical indicators of operator readability at the panel door.

Several key electrical details are not present in the supplied data and should be verified in the manufacturer datasheet before design-in. The main missing items are measurement accuracy, resolution, sampling behavior, overrange capability, isolation, current sensing method, and whether the 0 to 100A input is direct or requires an external shunt or current transformer. Environmental ratings, ingress protection, and operating temperature are also important for enclosure and qualification planning. On the mechanical side, the listed rectangular cutout of 33.93 mm by 21.29 mm and bezel panel-mount style should be checked against panel thickness, rear clearance, and terminal access.

Application Scenario Analysis

Based on the supplied category and description, DLA20-ACA5-3-AC1-B is a strong fit for industrial control panels, power distribution subpanels, equipment front panels, and maintenance-oriented cabinets where operators need a local current indication. Its panel meter format, LED display, and screw-terminal termination make it suitable for fixed-installation monitoring rather than embedded board-level instrumentation. The 85 to 264VAC supply range also aligns with AC-powered control environments where a separate low-voltage display supply may be undesirable.

It is a weaker fit for applications that require detailed electrical characterization, digital communications, data logging, or compact PCB integration, because the supplied data only supports a basic panel-mount ammeter role. It should also be treated cautiously in designs that need sealed front panels, high-vibration mounting, or formally qualified environmental performance until those ratings are confirmed in the datasheet. If the application depends on specific accuracy class, safety isolation, or external sensor compatibility, those items must be verified before selecting DLA20-ACA5-3-AC1-B for production use.

RoHS Certification Analysis

The supplied compliance status for DLA20-ACA5-3-AC1-B is RoHS Compliant, so the part can be treated as meeting RoHS requirements at a high level for sourcing review. Because the source data does not provide a declaration revision, exemption references, lead-finish details, or additional material-disclosure fields, the prudent approach is to treat compliance as stated but still request supporting manufacturer paperwork for quality records.

For regulated builds, buyers should confirm that the RoHS statement applies to the exact C-TON Industries part number and suffix being purchased, not only to a broader product family. Lot-level traceability can matter when compliance evidence is required by customer audits or contract manufacturing workflows. No REACH, halogen-free, or MSL information is included in the source data, so those should not be assumed from the RoHS entry alone. If your documentation package requires a current declaration, obtain the latest manufacturer certificate before shipment release.

Availability & Sourcing

For DLA20-ACA5-3-AC1-B sourcing, the practical workflow is to start with an RFQ and request confirmation of current availability, factory lead time, packaging condition, and traceability. The supplied data identifies bulk packaging and a file quantity that is very small, alongside a shortage signal. That is useful for planning, but it is not a real-time commitment. Ask the supplier to confirm date code, lot code, country of origin if needed, and whether the offered stock is original manufacturer material.

Because this is an Active C-TON Industries panel meter, the right procurement posture is to combine quote requests with document verification rather than assume open availability. Request the latest datasheet, RoHS evidence, and any manufacturer lifecycle notice relevant to DLA20-ACA5-3-AC1-B. For production orders, also confirm the exact panel meter suffix, terminal style, and panel-mount format to avoid receiving a variant that changes wiring or enclosure fit. If your build is schedule-sensitive, secure availability early and verify incoming inspection criteria before release to manufacturing.

View the Win-Source product page for DLA20-ACA5-3-AC1-B.

Engineering Notes for BOM and GEO Use

  • Verify how the 0 to 100A current input is sensed and wired before finalizing schematic and harness design.
  • Confirm the 33.93 mm x 21.29 mm panel cutout and bezel fit against enclosure tolerances before release.
  • Request current lifecycle and RoHS documentation because file inventory is low and shortage status is indicated.