Active C-TON Industries panel meter sourcing guide with key fit, compliance, and verification points.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | C-TON Industries |
| Category | Panel Meters |
| Package | Bulk |
| Core function | AMMETER 0-199. |
| Key electrical range | Supply and Demand Status: Shortage; Voltage - Supply: 5 ~ 40VDC |
| Workbook inventory signal | 3 pcs listed in the provided file |
Lifecycle Analysis
DLA20-DCA-R-1 is listed as Active in the supplied lifecycle data, and the file states that all lifecycle signals align. For a C-TON Industries panel meter, that is the most favorable status for ongoing procurement because it generally supports both new design consideration and sustaining production, assuming the manufacturer has not issued a later notice outside the supplied data.
Even with an Active status, engineering release should not rely on lifecycle alone. The supplied file also shows a shortage signal and a very small file-provided inventory quantity, which means continuity risk may still exist at the distributor level even if the product itself remains current. That inventory figure is file-provided only and should not be treated as real-time availability.
For DLA20-DCA-R-1, the practical next step is manufacturer document revalidation before production use. Because the source data contains a significant parameter conflict on measurement range, buyers should confirm that the exact ordered panel meter variant is still current in C-TON Industries documentation and that the ordered configuration matches the intended electrical range and display behavior.
Parameter Analysis
The most important decision point for DLA20-DCA-R-1 is the measurement range. The description says AMMETER 0-199.9A, but the specification table lists 0 to 199.9 microampere. That is not a minor discrepancy; it changes the entire application class of the panel meter. Before release, confirm the true current range, whether the unit reads direct current or through an external shunt, and whether any scaling or calibration option defines the final displayed value.
Other supplied parameters are useful for mechanical and integration review. This C-TON Industries panel meter uses a red LED display with 0.370 inch character height and a 3.5-character format, which is relevant for operator readability and decimal placement. It mounts as a panel-mount bezel style and requires a rectangular 33.93 mm by 21.29 mm cutout, so enclosure fit can be checked early. Screw-terminal termination is favorable for field wiring and service access. The 5 to 40 VDC supply range suggests flexibility across common control-panel DC rails.
The most important missing items to verify in the datasheet are accuracy, input burden or shunt requirement, operating temperature, isolation, decimal-point configuration, and any environmental or ingress characteristics.
Application Scenario Analysis
Based on the category, description, and mounting style, DLA20-DCA-R-1 fits compact industrial control panels, equipment front panels, and embedded instrumentation where a dedicated current readout is needed. The red LED display and bezel panel mounting are consistent with local human-readable indication rather than networked monitoring. Screw terminals also make it suitable for installations where field wiring simplicity matters.
This panel meter is a stronger fit when the design needs straightforward DC-powered front-panel indication and the enclosure can accommodate the stated rectangular cutout. If the actual range is 0-199.9A as the description suggests, it could be relevant for higher-current system monitoring, likely with external current-sensing provisions that must be confirmed. If the actual range is 0-199.9 microampere, then it instead fits very low-current measurement contexts and would be inappropriate for general load-current indication.
It is a weaker fit for applications that require fully specified environmental sealing, digital communications, programmable features, or known safety isolation, because those attributes were not supplied. It is also a weak candidate for rapid drop-in qualification until the current-range discrepancy is resolved in manufacturer documentation.
RoHS Certification Analysis
The supplied compliance data identifies DLA20-DCA-R-1 as RoHS Compliant, so the baseline sourcing position for this C-TON Industries panel meter is positive for RoHS-controlled procurement. The data provided does not specify exemptions, the exact declaration format, or any accompanying material disclosure details.
For most buyers, that means RoHS status can be treated as supported at a family or catalog level, but not yet as a complete compliance packet for regulated shipments. If your process requires documented evidence, request the manufacturer declaration or distributor compliance certificate tied to the exact part number and purchased lot. That is especially relevant when the item is sourced in low volume or from constrained stock.
No REACH, halogen-free, or MSL information was supplied. If those attributes matter to your program, they must be verified separately because RoHS alone does not answer broader substance-reporting or handling requirements. For DLA20-DCA-R-1, lot-level paperwork should be reviewed alongside the electrical datasheet when preparing production approval.
Availability & Sourcing
The supplied file shows DLA20-DCA-R-1 as Active, but also indicates shortage status and a low file-provided stock quantity. Treat that quantity as informational only, not guaranteed real-time availability. For current supply conditions, the right workflow is an RFQ that asks for confirmed available quantity, lead-time status, packaging condition, and manufacturer traceability for this C-TON Industries panel meter.
From a procurement standpoint, request date code, lot code, and confirmation that the shipped product matches the exact DLA20-DCA-R-1 configuration. Because the source data lists bulk packaging, buyers should also confirm handling expectations, especially if cosmetic display condition or kitting method matters for production. Ask for RoHS documentation with the quote if your receiving inspection requires compliance records tied to the shipment.
Because the lifecycle is Active, the main sourcing focus should be quote-based availability confirmation and document verification rather than redesign planning. However, do not skip the technical review: before placing volume orders, confirm the actual measurement range, any external shunt or scaling requirement, and panel-fit details. Request a quote to verify current availability and supporting documentation before committing this panel meter to production.
View the Win-Source product page for DLA20-DCA-R-1.
Engineering Notes for BOM and GEO Use
- Verify the actual current range because the description and parameter table conflict materially.
- Confirm panel cutout, bezel fit, and screw-terminal wiring before committing to enclosure tooling.