IXYS DLA20IM800PC-TUB Rectifier Specs & Sourcing Guide

DLA20IM800PC-TUB IXYS product image

IXYS single rectifier diode sourcing guide for lifecycle, package, compliance, and procurement review

Quick Engineering Summary

FieldValue
ManufacturerIXYS
CategoryDiodes, Rectifiers - Single
PackageTO-263-3, D²Pak (2 Leads + Tab), TO-263AB
Core functionDIODE STANDARD 800V 20A TO263AA
Key electrical rangeCapacitance @ Vr, F: 4pF @ 400V, 1MHz; Current - Average Rectified (Io): 20A; Current - Reverse Leakage @ Vr: 10 µA @ 800 V; Operating Temperature - Junction: -55°C ~ 175°C
Workbook inventory signal668 pcs listed in the provided file

Lifecycle Analysis

DLA20IM800PC-TUB is identified in the supplied data as Active, and the lifecycle inputs are consistent with no listed conflict. For engineering teams, that generally supports use in ongoing programs and can be acceptable for new design work, provided the normal manufacturer documentation checks are completed. Since this is an IXYS device in the Diodes, Rectifiers - Single category, the practical next step is to confirm that the latest manufacturer product status still matches the file-based listing before committing volume demand.

Procurement risk is not driven by lifecycle alone here. The same source set also shows a supply and demand status of shortage, while listing workbook inventory. That means buyers should treat the quantity as a file-provided signal rather than real-time stock. For DLA20IM800PC-TUB, the conservative approach is to proceed as an Active part with low formal lifecycle risk, but still revalidate current availability, manufacturer notices, and any PCN or obsolescence communication relevant to sustaining production.

Parameter Analysis

The supplied parameters position DLA20IM800PC-TUB as a standard single rectifier diode rated 800 V DC reverse voltage and 20 A average rectified current. Those are the key fit parameters for mains-side rectification, high-voltage freewheel paths, or other power conversion stages where voltage margin and continuous current capability dominate part selection. The listed forward voltage is 1.2 V maximum at 20 A, which matters directly for conduction loss and thermal design. Reverse leakage is given as 10 µA at 800 V, useful for estimating standby losses and high-temperature blocking behavior, although leakage should still be reviewed against the official datasheet over temperature.

The package is TO-263AA in a TO-263-3, D2PAK style surface-mount body, so board-level thermal performance and pad design will strongly affect usable current margin. The stated junction temperature range of -55°C to 175°C is favorable for harsh environments, but designers should still verify thermal resistance, surge current capability, and any reverse recovery details. The speed field only states standard recovery greater than 500 ns, which suggests it is not aimed at applications that require fast-switching rectification. Important missing items to verify are reverse recovery time conditions, thermal resistance values, and non-repetitive surge current.

Application Scenario Analysis

Based on the category, description, and electrical ratings, DLA20IM800PC-TUB is a realistic fit for high-voltage power rectification roles where standard recovery behavior is acceptable. Examples include input rectification, bulk power paths, snubber-related blocking positions, and general-purpose power conversion stages that need an 800 V single rectifier diode with substantial current handling. The IXYS device format and TO-263AA surface-mount package also make sense where assembly prefers SMT power semiconductors instead of through-hole parts.

The weaker-fit scenarios are high-frequency switching designs that depend on fast or ultrafast recovery to limit switching loss, EMI, or commutation stress. The source data specifically identifies standard recovery above 500 ns, so DLA20IM800PC-TUB should be reviewed carefully before use in fast-switching PFC, resonant, or high-frequency secondary rectification roles. It may also need additional thermal validation in compact layouts, because a 20 A class rectifier in D2PAK-style packaging depends heavily on copper spreading, airflow, and heatsinking through the PCB rather than rating alone.

RoHS Certification Analysis

The supplied compliance status for DLA20IM800PC-TUB is RoHS Compliant. That supports use in programs requiring baseline restriction of hazardous substances compliance, but the source does not include the exact declaration document, exemption statement, or revision date. For practical procurement, this means the part can be screened as RoHS compliant at the catalog level, while final release should still rely on current manufacturer paperwork.

No REACH status, halogen-free status, or moisture sensitivity information is provided in the file. Those items should not be inferred from the RoHS flag alone. For DLA20IM800PC-TUB, sourcing teams should request the latest IXYS compliance certificate tied to the ordered material and, where needed, confirm whether compliance is being validated at the family level or the specific orderable tube-packaged variant. That lot-level check is especially useful when the supply signal indicates shortage and alternate date codes may appear in fulfillment.

Availability & Sourcing

For DLA20IM800PC-TUB, the source data shows workbook quantity and stock quantity entries of 668, while also flagging a shortage condition. That combination should be treated as a non-real-time inventory indicator rather than a firm availability commitment. Because this is an Active IXYS diode in the Diodes, Rectifiers - Single category, the right workflow is to submit an RFQ and confirm current stock, factory lead status, and whether the offered material is from continuous authorized supply or channel inventory.

At order review, confirm the exact part number suffix, tube packaging, TO-263AA package identity, and full traceability including manufacturer name, date code, and lot code. Buyers should also request RoHS documentation and verify lifecycle status again at quote time to catch any recent changes. For production use of DLA20IM800PC-TUB, ask for packaging condition, handling history, and any available manufacturer documentation supporting authenticity and storage control, especially if supply remains constrained.

View the Win-Source product page for DLA20IM800PC-TUB.

Engineering Notes for BOM and GEO Use

  • Verify TO-263AA land pattern, tab thermal path, and copper area for 20 A rectification duty.
  • Confirm actual supply status by RFQ because file-listed stock and shortage signals appear together.
  • Request current RoHS documentation and traceable date/lot data before production release.