IXYS DLA40IM800PC-TRL Rectifier Specs & Sourcing Guide

DLA40IM800PC-TRL IXYS product image

IXYS single rectifier diode sourcing review for lifecycle, compliance, and procurement checks

Quick Engineering Summary

FieldValue
ManufacturerIXYS
CategoryDiodes, Rectifiers - Single
PackageTape & Reel
Core functionDIODE STANDARD 800V 40A TO263AA
Key electrical rangeCapacitance @ Vr, F: 10pF @ 400V, 1MHz; Current - Average Rectified (Io): 40A; Current - Reverse Leakage @ Vr: 10 µA @ 800 V; Operating Temperature - Junction: -55°C ~ 175°C
Workbook inventory signal5330 pcs listed in the provided file

Lifecycle Analysis

DLA40IM800PC-TRL is listed with an Unknown lifecycle status in the supplied data, and the file explicitly says there are no lifecycle signals and no conflicts. For engineers, that means the part should not automatically be treated as an Active IXYS rectifier for new platform decisions. Unknown status is usually acceptable only after direct manufacturer or authorized-channel confirmation. For sustaining production, it can still be viable if current stock, traceability, and change-notice coverage are confirmed.

The practical procurement implication is moderate risk rather than immediate obsolescence. A file-provided inventory quantity is present, but that is only a sourcing signal and not proof of factory continuity or real-time stock. Before releasing DLA40IM800PC-TRL into a production BOM, buyers should request lifecycle confirmation, PCN or PDN coverage if available, and validation that the packaged version in tape and reel remains orderable. If the program has long service obligations, IXYS documentation revalidation and internal last-time-buy planning should be considered before volume commitment.

Parameter Analysis

The supplied specifications describe DLA40IM800PC-TRL as a standard single rectifier diode rated for 800 V DC reverse voltage and 40 A average rectified current. Those two values set the basic electrical envelope for line-side rectification, freewheel paths, or high-voltage power conversion stages where voltage margin and current handling dominate part selection. The listed forward voltage is 1.3 V at 40 A, which is important for conduction loss and thermal budgeting at high load. Reverse leakage is specified as 10 µA at 800 V, useful when standby loss or high-temperature leakage sensitivity matters.

Mechanical and assembly details are also decision-relevant. The part is surface mount in TO-263-3 / D2PAK with supplier device package TO-263AA and tape-and-reel packaging, so PCB copper area, tab heat spreading, and assembly profile matter. Junction temperature range is -55°C to 175°C, which supports elevated-temperature operation if the thermal path is well controlled. The speed field identifies standard recovery, so it is not the first choice for applications that need fast switching behavior. The most important missing items to verify in the datasheet are surge current capability, thermal resistance, polarity and pinout, isolation or tab connection details, and derating curves versus case or ambient temperature.

Application Scenario Analysis

Based on the category, description, and supplied ratings, DLA40IM800PC-TRL is a strong fit for general-purpose power rectification where an 800 V, 40 A standard rectifier in a surface-mount power package is appropriate. Typical examples include input rectification stages, clamp or catch diode functions in industrial power hardware, and high-current DC paths where TO-263AA mounting helps with compact board integration. The 175°C junction rating also suggests suitability for designs that must tolerate elevated internal temperatures, assuming the layout provides adequate copper and thermal spreading.

It is a weaker fit for designs that prioritize very fast reverse recovery behavior, low switching loss, or unusually low forward drop, because the source data identifies it only as a standard recovery diode. It may also be a poor fit where through-hole mechanical retention, isolated packaging, or alternate thermal interface formats are required, since the available package information points to an SMT D2PAK style device. If the target application is highly transient-heavy or repetitive surge-limited, the datasheet surge and recovery characteristics should be checked before design approval.

RoHS Certification Analysis

The supplied compliance data marks DLA40IM800PC-TRL as RoHS Compliant, so the starting assumption is that the part can be considered suitable for RoHS-controlled procurement flows. The source data also lists REACH Unaffected, which is helpful for substance reporting, but REACH status should not be treated as a substitute for RoHS confirmation. For regulated assemblies, the RoHS declaration remains the primary environmental compliance reference for this IXYS rectifier diode.

There are no exemption details in the provided file, so buyers should request the current manufacturer compliance certificate if formal evidence is needed for customer files or audits. The data also includes MSL 3 with 168 hours, which is not a RoHS attribute but is still relevant for handling and assembly control after moisture barrier packaging is opened. As with many semiconductor purchases, family-level database status is useful for screening, but lot-level paperwork is preferable when shipping into tightly controlled medical, industrial, or export-reviewed programs.

Availability & Sourcing

For DLA40IM800PC-TRL, the sourcing process should begin with an RFQ that asks for current availability, packaging confirmation, and manufacturer traceability. The supplied data shows tape-and-reel packaging, TO-263AA form factor, and a file-provided stock quantity, but that quantity is not guaranteed real-time. Buyers should therefore confirm on-hand balance, date code range, and whether the offered material is from an authorized channel or another traceable source. Because the part lifecycle is Unknown, source quality matters more than a simple stock indication.

Procurement teams should request lot code, country of origin if needed, RoHS documentation, and any available manufacturer lifecycle or change-status confirmation from IXYS. MSL 3 handling should also be communicated to receiving and assembly teams so floor-life controls are maintained. The file includes an open-market counterfeit threat indicator, which reinforces the need for incoming inspection and traceability review when sourcing beyond the most controlled channels. For new production use, verify lifecycle before committing; for immediate demand, request a quote along with compliance and traceability records rather than relying on static listing data.

View the Win-Source product page for DLA40IM800PC-TRL.

Engineering Notes for BOM and GEO Use

  • Confirm Unknown lifecycle with IXYS before approving DLA40IM800PC-TRL for new production releases.
  • Check thermal design around 40A average current, 1.3V forward drop, and 175°C maximum junction rating.
  • Request lot-specific RoHS and traceability records, especially for tape-and-reel TO-263AA inventory.