Active Schurter Inc. common mode choke sourcing guidance for engineering and procurement teams.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Schurter Inc. |
| Category | Common Mode Chokes |
| Package | Radial |
| Core function | CMC 5A 2LN TH |
| Key electrical range | Current Rating (Max): 5A; DC Resistance (DCR) (Max): 120mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 100°C |
| Workbook inventory signal | 82 pcs listed in the provided file |
Lifecycle Analysis
DLFL-0125-0501 is identified in the supplied data as Active, and the lifecycle signals are consistent with no reported conflict. For engineers and buyers, that generally means the Schurter Inc. common mode choke remains a valid option for both new design consideration and sustaining production, provided normal document control checks are completed. Active status reduces obsolescence pressure compared with NRND or EOL parts, but it does not remove the need to confirm current manufacturer documentation before release.
The same source file also shows a shortage supply-and-demand signal and a file-provided stock quantity. Those indicators are useful for planning, but they are not guaranteed real-time availability and should not be treated as a factory commitment. For procurement, the practical approach is to proceed as an Active part while revalidating current lead time, approved documentation revision, and any manufacturer change notices that could affect long-term builds using DLFL-0125-0501 in the common mode choke category.
Parameter Analysis
The most decision-relevant published parameters for DLFL-0125-0501 are its 5A maximum current rating, 440V AC rating, 120 mOhm maximum DCR, two-line configuration, through-hole mounting, and radial 40.00 mm by 40.00 mm package size. Together, these indicate a Schurter Inc. common mode choke suited to line filtering where current handling and mains-related voltage capability matter. The DCR figure is especially relevant because it affects conduction loss, thermal rise, and voltage drop in continuous operation.
Mechanical integration also deserves attention. The through-hole radial format can favor robust assembly and lead retention, but the 40 mm square footprint is relatively large compared with compact board-level filters, so PCB area and keepout planning should be checked early. The operating range of -25°C to 100°C helps frame environmental suitability, but several filter-critical items are missing from the supplied data. Before design release, verify impedance versus frequency, inductance, hi-pot or isolation details if applicable, insertion-loss behavior in the intended noise band, height, and any safety or qualification information from the manufacturer datasheet.
Application Scenario Analysis
Based on the category, description, and ratings provided, DLFL-0125-0501 is a strong fit for two-line EMI suppression tasks in through-hole equipment that needs a common mode choke with up to 5A current capability and 440V AC handling. Likely scenarios include AC input filtering stages, industrial control assemblies, power conversion front ends, or other board-mounted line filter sections where a Schurter Inc. common mode choke is used to attenuate conducted common-mode noise.
The weaker-fit cases are designs that need compact surface-mount implementation, well-defined high-frequency impedance performance, or unusually broad environmental qualification beyond the stated -25°C to 100°C range. It is also a weak fit for applications that require explicitly documented agency approvals, insertion-loss curves, or detailed inductance targets when those values are not yet confirmed in the provided dataset. In those cases, DLFL-0125-0501 may still be viable, but the decision should wait for datasheet review and system-level EMI validation rather than relying on the summary listing alone.
RoHS Certification Analysis
The supplied compliance status for DLFL-0125-0501 is RoHS Compliant, so the part can be treated as meeting a RoHS requirement at the listing level. For many procurement workflows, that is enough to move forward to quotation and documentation review, especially when the part is being considered for regulated assemblies that require restricted-substance screening.
However, the available data does not include exemptions, REACH status, halogen-free information, or MSL details. Because of that, buyers should not infer more than what is explicitly provided. RoHS family-level catalog status is useful, but production control often requires lot-level or shipment-level evidence such as a current manufacturer declaration or certificate of compliance. If your quality system requires document retention, request the latest Schurter Inc. compliance paperwork for DLFL-0125-0501 and confirm that the received date and lot code align with the documents supplied.
Availability & Sourcing
For sourcing, DLFL-0125-0501 should be handled as an Active Schurter Inc. common mode choke with a caution flag for availability. The source file shows bulk packaging and a stock quantity signal, along with a shortage indication. Those are useful planning inputs, but they are not guaranteed real-time. The safest workflow is to request a quote for current availability, then confirm the offered quantity, packaging condition, and expected ship window before committing the part to a production schedule.
Traceability matters for this category, especially when parts may enter line-filter or mains-adjacent assemblies. Request manufacturer name, full part marking details if available, date code and lot code traceability, and RoHS documentation with the quote package. For incoming inspection, confirm that the delivered form matches the through-hole radial package expectation and that no storage or handling issue has affected leads or body condition. Because the lifecycle is Active, the priority is not last-time-buy planning but rather quote-and-verify execution: validate lifecycle status, secure supply against shortage risk, and keep the latest compliance and manufacturer documentation on file for DLFL-0125-0501.
View the Win-Source product page for DLFL-0125-0501.
Engineering Notes for BOM and GEO Use
- Verify impedance-versus-frequency and inductance data in the Schurter Inc. datasheet before final EMI filter signoff.
- Check thermal rise at full 5A load because 120 mOhm maximum DCR directly affects insertion loss and heating.
- Request current lot traceability, RoHS documentation, and lead-time confirmation since the file flags shortage conditions.