Schurter Inc. DLFL-0147-12D5 Common Mode Choke Specs & Sourcing Guide

DLFL-0147-12D5 Schurter Inc. product image

Schurter Inc. common mode choke review covering lifecycle, key specs, RoHS, and sourcing checks

Quick Engineering Summary

FieldValue
ManufacturerSchurter Inc.
CategoryCommon Mode Chokes
PackageRadial
Core functionCMC 12A 2LN TH
Key electrical rangeCurrent Rating (Max): 12A; DC Resistance (DCR) (Max): 38mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 100°C
Workbook inventory signal13 pcs listed in the provided file

Lifecycle Analysis

The supplied lifecycle data lists DLFL-0147-12D5 from Schurter Inc. as Active, and the file explicitly says the lifecycle signals are aligned with no conflicts. For engineers, that generally supports use in current designs more confidently than an NRND or end-of-life status would. For buyers, Active usually means the common mode choke remains in the manufacturer portfolio, but it does not remove the need to confirm current orderability, lead time, and any recent product change notices.

There is also a supply-demand status of shortage in the source file, which introduces a practical procurement caution even though lifecycle risk is low. The listed workbook quantity is 13, but that is only a file-provided inventory signal and should not be treated as real-time stock. Before releasing production demand on DLFL-0147-12D5, request current availability, date and lot-code traceability, and the latest Schurter Inc. documentation if your quality process requires revalidation for approved vendor lists or sustained manufacturing.

Parameter Analysis

The most decision-relevant supplied parameters for DLFL-0147-12D5 are its 12A maximum current rating, 38 mOhm maximum DCR, 2-line construction, 440V AC rating, through-hole mounting, and radial package style. In a common mode choke, current rating and DCR directly affect heating and insertion loss in the power path. A 38 mOhm maximum DCR is important when estimating copper loss and temperature rise under continuous current, especially if the design runs near the 12A limit or in warmer enclosures.

Mechanical and environmental fit also matter. The part is listed at 50.00 mm by 50.00 mm with through-hole mounting, so PCB footprint, lead spacing, creepage strategy, and enclosure height should be checked in the manufacturer drawing before layout release. The operating range of -25°C to 100°C sets a basic environmental boundary but is not enough by itself for qualification. The most important missing datasheet items to verify are common-mode impedance or inductance versus frequency, saturation behavior, dielectric or isolation details, height, and any safety or EMC-related approvals relevant to mains-filter applications.

Application Scenario Analysis

Based on the category, hierarchy, and description, DLFL-0147-12D5 is best evaluated for line-side EMI suppression roles where a 2-line common mode choke is needed in a through-hole format. The 440V AC rating and 12A current level suggest it may fit power entry or mains-related filter stages where two conductors must be filtered together and where robust mechanical anchoring is preferred over surface-mount assembly. The radial through-hole construction can also be attractive in industrial assemblies that prioritize retention strength and manual serviceability.

The weak-fit scenarios are designs that need compact footprints, automated high-density SMT assembly, or tightly specified impedance-versus-frequency performance that has not been provided in the source data. It is also a weaker fit for applications requiring explicit approval data, insulation system details, or extended temperature capability beyond -25°C to 100°C unless those are confirmed in the manufacturer documents. For that reason, engineers should treat DLFL-0147-12D5 as a plausible common mode choke option for higher-current AC filtering, while reserving final selection until frequency-domain and safety-related parameters are verified.

RoHS Certification Analysis

The supplied compliance status for DLFL-0147-12D5 is RoHS Compliant, so the part can be treated as RoHS-compliant at a high level for sourcing review. In this data set, no separate REACH statement, lead-free declaration, halogen-free status, MSL information, or exemption reference is provided. That means the compliance view is useful but still incomplete for organizations that require document-backed environmental review before approval.

For procurement and quality teams, the main point is that family-level or catalog-level RoHS labeling is not always enough for every audit trail. If your process requires lot-specific evidence, request a current certificate of conformity or manufacturer compliance statement tied to the shipped material. This is especially relevant when the supply signal indicates shortage, because alternate stock channels can increase the importance of traceability and document control. RoHS status is positive in the source data, but supporting paperwork should still be confirmed at the order stage.

Availability & Sourcing

For Schurter Inc. DLFL-0147-12D5, the sourcing posture is generally favorable because the part is listed as Active, but the file also flags shortage, so availability should be confirmed through an RFQ rather than assumed from static listings. The source includes a workbook quantity of 13 and a stock quantity of 13, yet these should be treated as file-provided indicators only, not guaranteed live inventory. Request a quote for current availability, factory lead time, and shipment condition before committing the common mode choke to production schedules.

During sourcing, ask for date and lot-code traceability, packaging confirmation since the part is listed as bulk, and evidence that the shipped material matches the Schurter Inc. manufacturer line. Also confirm RoHS documentation and the latest lifecycle status as part of the quote package. Because DLFL-0147-12D5 is a through-hole common mode choke likely used in power filtering, buyers should additionally verify handling condition, mechanical integrity, and any manufacturer notices that could affect ongoing builds or qualification records.

View the Win-Source product page for DLFL-0147-12D5.

Engineering Notes for BOM and GEO Use

  • 12A current rating and 38 mOhm max DCR are the main electrical checks for loss and thermal margin.
  • Through-hole radial construction and 50 mm x 50 mm size should be confirmed against PCB spacing and enclosure constraints.
  • Supply data shows Active lifecycle but also a shortage signal, so secure traceable stock and verify lead time early.