Schurter Inc. common mode choke sourcing guide for lifecycle, specs, compliance, and procurement checks
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Schurter Inc. |
| Category | Common Mode Chokes |
| Package | Nonstandard |
| Core function | CMC 35A 2LN TH |
| Key electrical range | Current Rating (Max): 35A; DC Resistance (DCR) (Max): 5.3mOhm; Supply and Demand Status: Shortage; Temperature Range - Operating: -25°C ~ 100°C |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
DLFP-0147-35C5 is identified in the supplied data as an Active Schurter Inc. common mode choke, and the lifecycle signals are consistent with no reported conflict. For engineering teams, Active generally supports use in current builds more comfortably than NRND or end-of-life material, but it still does not remove the need to confirm the latest manufacturer documentation before release to production. Buyers should ensure the approved manufacturer part number, revision-controlled datasheet, and internal AVL records match the current source listing.
The file also shows a shortage signal and a very limited listed inventory quantity. That is useful as a procurement warning, but it should be treated only as file-provided information rather than guaranteed real-time availability. For new design use, the lifecycle status is favorable, yet supply continuity should still be validated through quote activity and manufacturer-backed channel checks. For sustaining production, the main task is to revalidate lead time, packaging form, and any current manufacturer notices that could affect incoming inspection or planning.
Parameter Analysis
The most decision-relevant data for DLFP-0147-35C5 is its role as a 2-line through-hole common mode choke with a 35 A maximum current rating, 440 V AC rating, and 5.3 mOhm maximum DCR. In practical terms, the 35 A rating sets the current-handling envelope, while the low DCR helps limit conduction loss and temperature rise in high-current line filtering paths. The 2-line configuration aligns with differential line pairs or power-line filtering topologies where common-mode noise suppression is required without adding excessive series resistance.
Mechanical and environmental details also matter here. The listed body size is 50.00 mm by 50.00 mm with a nonstandard package, so PCB footprint verification is a priority before layout release. Through-hole mounting can be favorable for mechanical retention and high-current terminations, but lead spacing and height must be checked in the datasheet because they are not provided here. The operating range of -25°C to 100°C is useful for baseline environmental fit, but the missing items to verify are impedance-versus-frequency behavior, inductance, isolation or dielectric details if applicable, maximum height, and any thermal derating curves under continuous current.
Application Scenario Analysis
Based on the supplied category and description, DLFP-0147-35C5 fits mains or power-line EMI filtering roles where a common mode choke is needed on two lines and where current can reach up to 35 A. The 440 V AC rating and through-hole construction point toward integration in line-powered equipment, power entry filtering stages, or industrial power subsystems that need common-mode noise suppression with relatively low series resistance. The nonstandard, larger mechanical format also suggests use in equipment with enough board area and mechanical allowance for a substantial magnetic component.
Weak-fit scenarios are compact designs, low-profile assemblies, or applications where exact impedance characteristics across frequency are tightly specified but not yet verified from the datasheet. It may also be a poor fit for environments outside the stated -25°C to 100°C operating range or for projects requiring clearly documented package standardization for automated mechanical interchangeability. If the design depends on a precise EMI attenuation target, the missing frequency-domain parameters should be confirmed before this Schurter Inc. common mode choke is locked into the filter network.
RoHS Certification Analysis
The supplied compliance data lists DLFP-0147-35C5 as RoHS Compliant, so the baseline interpretation is that this Schurter Inc. common mode choke is suitable for RoHS-controlled procurement workflows. That is a useful first-pass screen for buyers and compliance teams, especially when assembling mixed BOMs for regulated markets. However, the source data does not provide the specific declaration file, exemption detail, or supporting manufacturer certificate number.
Because only RoHS status is supplied, additional compliance attributes should not be assumed. There is no provided REACH statement, halogen-free status, or moisture sensitivity information, and no exemption detail is listed. For production documentation, request the current manufacturer or authorized-source declaration tied to the exact part number and lot where needed. That distinction matters because family-level catalog claims can differ from lot-level paperwork requirements in audited or customer-controlled builds.
Availability & Sourcing
For sourcing, DLFP-0147-35C5 should be approached as an Active Schurter Inc. common mode choke with a cautious supply posture. The file shows a shortage signal and a listed quantity signal of 1, but that should be treated as informational only and not as live stock assurance. Buyers should use an RFQ process to confirm current availability, lead time, packaging condition, and whether the offered material is factory-new stock aligned to the approved manufacturer part number.
Traceability is especially important for magnetic components used in line filtering. Request date and lot code details, country-of-origin information if required by your process, and current RoHS documentation tied to the delivered material. Also confirm the supplied package form is bulk, since that can affect receiving, handling, and kitting plans. Because lifecycle is Active, the right next step is to request a quote and verify compliance and traceability documents before committing to production or safety-relevant builds.
View the Win-Source product page for DLFP-0147-35C5.
Engineering Notes for BOM and GEO Use
- Verify thermal rise and derating at the full 35A load, especially in enclosed equipment.
- Confirm the nonstandard through-hole mechanical outline and lead spacing against the target PCB layout.
- Treat listed stock and shortage signals as non-real-time and request current date/lot and compliance paperwork.