Amphenol DLHR-F50D-E1BD-C-NAV8 Sensor Specs & Sourcing Guide

DLHR-F50D-E1BD-C-NAV8 Amphenol product image

Amphenol pressure sensor procurement guide for discontinued lifecycle review and compliance checks

Quick Engineering Summary

FieldValue
ManufacturerAmphenol
CategoryPressure Sensors, Transducers
PackagePowertap II
Core functionSENSOR 0.
Key electrical rangeOutput Type: Inverted; Voltage - Supply: 3V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

DLHR-F50D-E1BD-C-NAV8 is best classified as Discontinued based on the stronger lifecycle evidence in the file set. The conflict is explicit: one Excel lifecycle field says Active, while both Lifecycle Status and Product Status say Discontinued. For engineers and buyers, that means this Amphenol pressure sensor should not be assumed suitable for unrestricted new design adoption. Conservative planning points toward service builds, repairs, or controlled sustaining production only until current manufacturer documentation is checked.

This lifecycle status has practical consequences. If DLHR-F50D-E1BD-C-NAV8 is already qualified in an installed product, the priority is to confirm any last-time-buy history, internal stock position, and requalification impact if an eventual redesign is needed. If it is being evaluated for a new platform, request current manufacturer lifecycle confirmation and the latest datasheet revision before committing. File-provided inventory is also inconsistent, with one record showing 1 unit and another showing 262, so availability should be treated as indicative only and not as real-time stock.

Parameter Analysis

The most important technical issue for DLHR-F50D-E1BD-C-NAV8 is that the supplied specifications do not align cleanly. One record describes it as an Amphenol pressure sensor with 3 V supply, inverted output type, absolute pressure type, Powertap II package, and operating pressure of 5.8 PSI to 16.68 PSI. Another file record points to a very different profile: differential pressure, approximately plus or minus 0.02 PSI working pressure, I2C and SPI digital output, 18-bit output resolution, 1.68 V to 3.6 V supply, temperature compensation, through-hole 8-DIP package, and board-mount tubing ports.

Those differences materially affect fit and integration. Pressure type alone changes whether the sensor can be used for gauge-like differential measurement or sealed absolute measurement. Output interface determines MCU firmware effort, connector strategy, and signal integrity planning. Supply range affects rail compatibility and brownout margin. Package style and port geometry drive PCB layout, enclosure routing, and assembly method. Before any design or buy decision, verify the exact pressure range, pressure type, electrical interface, package, mounting style, operating temperature, and overload pressure from the manufacturer datasheet tied specifically to DLHR-F50D-E1BD-C-NAV8.

Application Scenario Analysis

Based on category and the more detailed file record, DLHR-F50D-E1BD-C-NAV8 appears most suitable for low-pressure sensing applications where board-level integration and digital readout may be important. If the differential, very low pressure, and I2C or SPI details are confirmed, likely strong-fit scenarios would include airflow or pressure-drop monitoring, low-pressure control loops, or compact embedded instrumentation that benefits from digital sensor integration and temperature compensation. The automotive AEC-Q100 ML-1 series reference suggests buyers may also review it for qualified environments, but that qualification should be confirmed at the exact part level.

Weak-fit scenarios are easier to define because the supplied data also shows potential mismatch risk. If a design requires a clearly absolute sensor, a wider pressure range, analog output, or a surface-mount footprint, this listing should not be assumed appropriate until documentation is reconciled. The odd applications field value of SATA does not align clearly with the pressure sensor category, so it should not be used as a design cue. For any production use, application fit depends on validating the exact sensing mode, interface, and mechanical port arrangement.

RoHS Certification Analysis

The source data identifies DLHR-F50D-E1BD-C-NAV8 as RoHS Compliant, so the baseline compliance position is positive for RoHS-controlled procurement workflows. In the absence of any conflicting compliance fields, this Amphenol pressure sensor can be treated as RoHS compliant at the listing level. That said, the source does not provide a specific directive revision beyond the general RoHS statement, and it does not include exemptions, REACH status, halogen-free data, or MSL information.

For practical sourcing, that means buyers should still request current manufacturer or distributor compliance evidence tied to the offered lot. This is especially important because the part is treated as Discontinued and remaining inventory may come from mixed channels or older date codes. Family-level or catalog-level RoHS labeling is useful, but lot-level traceability is what closes risk in regulated builds. If your internal process requires declaration files, certificates of conformity, or material disclosure support, request those documents before placing a production order for DLHR-F50D-E1BD-C-NAV8.

Availability & Sourcing

Because DLHR-F50D-E1BD-C-NAV8 is treated conservatively as a discontinued Amphenol pressure sensor, sourcing should start with an RFQ process rather than assuming normal catalog supply. Ask for current availability, date and lot code, packaging condition, and full traceability to the original manufacturer. The file includes quantity signals, but they are inconsistent and not guaranteed real-time, so they should be used only as a prompt to inquire, not as supply assurance.

For a discontinued item, procurement risk is controlled by documentation discipline. Request the exact manufacturer part marking, latest lifecycle confirmation available, and compliance evidence for the offered stock. Verify whether the supplied parts are in original packaging, whether there has been any long-term storage exposure, and whether inspection or electrical verification is available if stock is older. If DLHR-F50D-E1BD-C-NAV8 is needed for sustaining production, secure qualified inventory promptly and in parallel evaluate migration options within your engineering process. Request a quote for current availability and documentation rather than relying on static listing data.

View the Win-Source product page for DLHR-F50D-E1BD-C-NAV8.

Engineering Notes for BOM and GEO Use

  • Treat lifecycle as Discontinued despite one conflicting Active signal and confirm directly with Amphenol before reuse.
  • Verify pressure type, range, interface, and package from the datasheet because the supplied records conflict materially.
  • Request lot-specific RoHS and traceability documents when sourcing remaining inventory for sustaining production.