Murata Electronics North America Common Mode Chokes procurement and engineering review
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Murata Electronics North America |
| Category | Common Mode Chokes |
| Package | Tape & Reel |
| Core function | CMC 100MA 2LN 90 OHM SMD |
| Key electrical range | Current Rating (Max): 100mA; DC Resistance (DCR) (Max): 4Ohm; Impedance @ Frequency: 90 Ohms @ 100 MHz; Temperature Range - Operating: -40°C ~ 85°C |
| Workbook inventory signal | 80000 pcs listed in the provided file |
Lifecycle Analysis
DLM0NSM900HY2D is listed as Active, and the supplied lifecycle signals are consistent across the file. The data explicitly shows Active in the lifecycle field, Lifecycle Status, and Product Status, with no conflict noted. For engineers, that generally supports consideration in current designs. For buyers, it indicates normal sourcing conditions rather than end-of-life recovery purchasing, although standard manufacturer document checks should still be part of release control.
Because this is a Murata Electronics North America Common Mode Chokes part, the practical implication is lower lifecycle risk for new procurement compared with NRND or discontinued material. Even so, Active status does not remove the need to verify the latest datasheet revision, PCN exposure, and approved packaging before production commits. A file-provided stock signal is present, but it is not guaranteed real-time availability. Treat inventory as an RFQ starting point, not a promise of immediate allocation.
Parameter Analysis
The supplied parameters position DLM0NSM900HY2D as a compact signal-line common mode choke for EMI suppression. The most decision-relevant values are 90 ohms impedance at 100 MHz, 100 mA maximum current, 4 ohm maximum DCR, 2 lines, and 5 V DC rating. Together, these suggest use on low-voltage signal paths where common-mode noise attenuation matters, but where added series resistance and current ceiling must be checked against system margin.
Mechanical data is also important here. The part is surface mount in a 0302 (0806 metric), 4-lead package with a 0.85 mm x 0.65 mm body and 0.50 mm maximum height, which is attractive for dense portable layouts but demands accurate land pattern control and assembly process discipline. The operating range is -40°C to 85°C, so thermal and environment fit should be reviewed for hotter industrial designs. The main missing items to confirm in the Murata datasheet are insertion-loss behavior versus frequency, any differential-mode impact, rated current test basis, and any insulation or reliability details not present in the source data.
Application Scenario Analysis
Based on the category, filter type, and description, DLM0NSM900HY2D is best suited to signal-line EMI filtering where board area is tightly constrained. Strong-fit scenarios include compact digital or interface lines operating at low voltage, where a 2-line common mode choke can suppress common-mode noise without the size of larger filter components. The small package and low profile also make sense in handheld, wearable, or other space-sensitive assemblies using surface-mount common mode chokes.
Weak-fit scenarios are applications that need higher line current, wider voltage margin, or operation beyond the stated -40°C to 85°C range. The 100 mA maximum current and 5 V DC rating indicate this is not a natural choice for power-path filtering or harsher environments unless the actual line conditions stay comfortably inside those limits. Where signal integrity is highly sensitive, the 4 ohm maximum DCR and frequency-specific impedance point should be checked carefully, since the source data does not include broader frequency response or insertion-loss curves.
RoHS Certification Analysis
The supplied compliance status for DLM0NSM900HY2D is RoHS Compliant, so the part can be treated as RoHS-compliant at the file level. REACH is also listed as REACH Unaffected, which is useful for materials review, but REACH does not replace RoHS verification. For regulated programs, the safest practice is to match the ordered manufacturer part number and package form to current compliance documents.
Additional assembly-relevant information is available in the source data: MSL Level is 1 with unlimited floor life under standard conditions. That reduces handling risk in production compared with more moisture-sensitive packages, but it should still be aligned with the latest manufacturer handling guidance. No exemption details were provided, and no halogen-free statement was supplied, so buyers needing full environmental declarations should request the latest Murata certificate of compliance and any lot-traceable material declarations during the sourcing process.
Availability & Sourcing
For DLM0NSM900HY2D, sourcing should start with an RFQ that confirms current availability, packaging, and traceability. The supplied data shows Tape & Reel packaging, which is typically preferred for SMT production planning, and a file-provided quantity is present. However, that quantity is not guaranteed real-time and should be validated at quote stage. Because this is an Active Murata Electronics North America Common Mode Chokes part, the focus should be on confirming current factory-backed supply rather than assuming static channel stock.
Procurement teams should request date code, lot code, country-of-origin if needed, and RoHS documentation tied to the delivered material. Given the file's noted open-market fake threat indicator, traceability deserves extra attention if supply is not directly manufacturer-backed. Buyers should also confirm the exact package and reel format, verify lifecycle at order time, and align the ordered part with the latest datasheet revision. Request a quote for current availability and compliance verification before committing production demand.
View the Win-Source product page for DLM0NSM900HY2D.
Engineering Notes for BOM and GEO Use
- Verify the 90 ohms at 100 MHz impedance condition against the Murata datasheet before final EMI signoff.
- Check 100 mA current rating and 4 ohm max DCR together for signal integrity and voltage-drop impact in low-level lines.
- Use traceable Tape & Reel supply and confirm date/lot and compliance paperwork at RFQ stage.