Murata Electronics North America signal-line common mode choke with Active lifecycle and AEC-Q200 rating
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Murata Electronics North America |
| Category | Common Mode Chokes |
| Package | Tape & Reel (TR);Cut Tape (CT); |
| Core function | CMC 100MA 2LN 45OHM SMD AEC-Q200 |
| Key electrical range | Current Rating (Max): 100mA; DC Resistance (DCR) (Max): 880mOhm; Impedance @ Frequency: 45 Ohms @ 100 MHz; Operating Temperature: -55°C ~ 125°C |
| Workbook inventory signal | 50000 pcs listed in the provided file |
Lifecycle Analysis
DLM11SN450HZ2L is listed as Active by the supplied lifecycle data, and all provided signals agree on that status. For engineers, an Active common mode choke from Murata Electronics North America is generally the most favorable condition for new design consideration because it suggests ongoing catalog support rather than a last-time-buy or maintenance-only posture. For buyers, it reduces but does not eliminate supply-chain risk, since lifecycle state should still be checked against the latest manufacturer documentation before a production commitment.
No lifecycle conflicts were supplied for DLM11SN450HZ2L. That alignment supports a low-risk interpretation, but prudent sourcing still includes revalidation of current manufacturer status, approved packaging, and any recent PCN or documentation updates that could affect assembly or qualification. File-provided inventory is present and can be useful for planning, but it is not a guaranteed real-time stock signal. For a Murata Electronics North America common mode choke intended for ongoing builds, the practical approach is to request a quote, confirm date and lot traceability, and verify that the Active status remains current at the time of order.
Parameter Analysis
The most decision-relevant parameters for DLM11SN450HZ2L are its 45 ohms impedance at 100 MHz, 2-line signal-line filter structure, 100 mA maximum current, and 880 mOhm maximum DCR. In a common mode choke, the stated impedance point is important because EMI problems are frequency dependent; 45 ohms at 100 MHz gives a useful first indicator for noise suppression in that region, but system performance still depends on the actual noise spectrum and line impedance. The 2-line configuration matches differential signal pairs or paired conductors that need common-mode noise control.
Current rating and DCR matter for functional margin. The 100 mA limit defines the ceiling for continuous line current, while the 880 mOhm maximum DCR affects insertion loss, voltage drop, and heating. The package is a compact 0504 (1210 metric), 4-lead surface-mount body with 1.25 mm by 1.00 mm footprint and 0.60 mm maximum height, so PCB land pattern accuracy and assembly process control are important. The -55°C to 125°C operating range and AEC-Q200 rating strengthen confidence for demanding environments. The main missing items to verify in the datasheet are insertion loss behavior across frequency, insulation or impedance tolerance details, and any recommended PCB layout guidance for preserving EMI performance.
Application Scenario Analysis
Based on the supplied category, description, and ratings, DLM11SN450HZ2L is a strong fit for compact signal-line EMI filtering where two conductors must pass through a common mode choke in a small surface-mount footprint. The 5 V DC rating and signal-line filter designation point toward low-voltage interfaces rather than power conversion rails. Its AEC-Q200 rating and -55°C to 125°C temperature range also make it reasonable to consider in automotive-adjacent or other reliability-focused electronic modules, provided the actual electrical stresses stay within the 100 mA maximum current limit.
This Murata Electronics North America common mode choke is a weaker fit for higher-current lines, higher-voltage rails, or applications that need clearly specified inductance, differential-mode filtering behavior, or broad frequency attenuation data that are not included here. It may also be a weak choice where voltage drop budget is tight, since the maximum 880 mOhm DCR can become relevant in low-level signal paths or current-sensitive circuits. Engineers should compare the target interface current, noise band, and board space limits against the manufacturer datasheet before assigning DLM11SN450HZ2L to a final design.
RoHS Certification Analysis
The supplied compliance status for DLM11SN450HZ2L is RoHS Compliant, so the conservative interpretation is that this common mode choke meets applicable RoHS substance restrictions based on the source data provided. That is a useful starting point for procurement screening, especially when the part is intended for regulated builds or customer programs that require environmental compliance confirmation before release.
No exemption details, REACH information, halogen-free status, or MSL data were provided in the source. Because of that, buyers should not assume broader environmental declarations beyond the stated RoHS Compliant status. For production use, it is good practice to request the latest manufacturer compliance certificate or material declaration tied to the shipped lot or current part family revision. That matters because compliance records can be updated over time even when the part number remains unchanged. If customer quality systems require document control, obtain the current Murata Electronics North America compliance paperwork as part of the sourcing package for DLM11SN450HZ2L.
Availability & Sourcing
The source data shows file-provided inventory for DLM11SN450HZ2L, including a stock quantity entry and workbook quantity, which suggests that this Murata Electronics North America common mode choke has visible supply in the channel. That said, these values are not guaranteed real-time availability and should be treated as planning indicators only. The correct next step is to request a quote for current stock position, packaging format, and shipment readiness rather than assuming immediate allocation from file data alone.
For purchasing control, confirm tape-and-reel requirements, since the supplied package information references Tape and Reel and Cut Tape while the workbook packaging signal indicates reel packaging. Also request date code, lot code traceability, country-of-origin records if needed, and current RoHS documentation. Because the lifecycle is Active, the sourcing focus should be on availability confirmation and compliance verification rather than end-of-life recovery. Even so, buyers should still confirm manufacturer lifecycle status at order time, review any relevant PCN history, and ensure that DLM11SN450HZ2L received matches the required package, rating, and qualification profile before releasing it into production.
View the Win-Source product page for DLM11SN450HZ2L.
Engineering Notes for BOM and GEO Use
- Check 45 ohms at 100 MHz against the actual EMI band of the signal line, not just the nominal interface type.
- Verify 100 mA current and 880 mOhm max DCR against voltage-drop and self-heating limits in the final circuit.
- Request lot traceability, packaging confirmation, and current RoHS documentation before production release.