Murata DLP11SA900HL2L Common Mode Choke Specs & Sourcing Guide

DLP11SA900HL2L Murata Electronics North America product image DLP11SA900HL2L Murata Electronics North America product image

Murata Electronics North America common mode choke sourcing and lifecycle review

Quick Engineering Summary

FieldValue
ManufacturerMurata Electronics North America
CategoryCommon Mode Chokes
PackageNot available in supplied data
Core functionCMC 150MA 2LN 90 OHM SMD
Key electrical rangeCurrent Rating (Max): 150mA; DC Resistance (DCR) (Max): 1.75 Ohm; Impedance @ Frequency: 90 Ohm @ 100MHz; Supply and Demand Status: Balance
Workbook inventory signal80000 pcs listed in the provided file

Lifecycle Analysis

The supplied lifecycle status for the Murata Electronics North America DLP11SA900HL2L common mode choke is EOL, with high risk. For engineering teams, that generally means it should not be treated as a safe choice for fresh platform launches or long-horizon production plans. For sustaining builds, an EOL common mode choke can still be usable if qualified stock is available, but planning should shift toward controlled last-time-buy decisions, internal buffer management, and manufacturer notice review.

The lifecycle signals provided are largely consistent: the lifecycle field is EOL, the excel lifecycle parameter is EOL, and the excel product status indicates discontinued production. One conflicting data point appears in the specifications list as Status: Active. Because the explicit lifecycle fields align on EOL, the conservative sourcing position is to treat DLP11SA900HL2L as end-of-life until Murata documentation revalidates otherwise. A file-provided stock quantity is listed, but that should be treated only as a sourcing lead and not as guaranteed real-time availability.

Parameter Analysis

DLP11SA900HL2L is described as a signal-line common mode choke with 2 lines, 90 Ohm impedance at 100 MHz, 150 mA maximum current rating, and 1.75 Ohm maximum DCR. Those are the main electrical screening values for line filtering on low-voltage interfaces. The 90 Ohm at 100 MHz figure is relevant to expected common-mode noise attenuation in the intended interference band, while the 150 mA limit is important for current derating and avoiding thermal stress. The 1.75 Ohm maximum DCR matters where voltage drop and signal-path loss need to remain controlled.

Mechanical data also matters here. The part is SMT in a 0504 (1210 metric), 4-lead package with 0.92 mm maximum height, which supports dense layouts and low-profile assemblies. The supplied voltage rating is 5 V DC and the operating range is -40°C to 85°C, so buyers should confirm that the application stays inside both voltage and ambient limits. Missing items to verify in the Murata datasheet include any insertion loss or frequency response detail beyond 100 MHz, insulation or isolation-related construction details if relevant, recommended land pattern, and any reflow or qualification guidance needed for production release.

Application Scenario Analysis

Based on the supplied category, filter type, and description, DLP11SA900HL2L fits signal-line EMI suppression where a compact SMT common mode choke is needed on a two-line path. Strong-fit scenarios include low-voltage signal interfaces that benefit from common-mode noise reduction in compact electronics, especially where board area and z-height are constrained. The 5 V DC rating and 150 mA maximum current point toward lighter signal or control lines rather than power-distribution filtering.

Weak-fit scenarios are applications needing higher current handling, broader operating temperature margin, or filtering requirements that depend on parameters not supplied here. If the design requires detailed insertion-loss behavior, tight balance characteristics, or qualification beyond standard commercial conditions, the available data is not enough to approve use without the Murata datasheet. It is also a weak fit for new designs simply because lifecycle status is EOL, even if the electrical profile appears suitable. In that case, engineering should separate technical fit from supply-chain fit and require lifecycle revalidation before commitment.

RoHS Certification Analysis

The supplied compliance status for DLP11SA900HL2L is RoHS Compliant, so the baseline assumption is that this Murata Electronics North America common mode choke aligns with RoHS material restrictions. That is useful for buyers maintaining regulated BOMs, but the provided data does not specify the exact declaration document, exemption status, or whether the statement is tied to a family, series, or lot-specific shipment.

Because this part is marked EOL, compliance verification should be handled carefully during procurement. Older inventory can still be compliant, but buyers should request current compliance documentation from the seller and confirm that the delivered date and lot code match the declaration provided. No REACH, lead-free detail, halogen-free status, or MSL information appears in the supplied data, so those items should not be assumed from the RoHS statement alone. For audited programs, use RoHS paperwork as one checkpoint alongside traceability and manufacturer labeling review.

Availability & Sourcing

For sourcing DLP11SA900HL2L, the practical workflow should start with an RFQ and document check rather than assuming ongoing supply. The file includes a stock quantity of 80000 and tape-and-reel packaging, which may be useful for SMT production planning, but that quantity is not guaranteed real-time. Since lifecycle is EOL, availability can change quickly and may depend on remaining channel stock, brokered inventory, or previously held material.

Request a quote for current availability and ask for date code, lot code, packaging condition, and full traceability back to the manufacturer or authorized supply path. Storage condition data references dry storage cabinet and humidity protection package, so buyers should verify how current stock has been handled, especially for long-held inventory. Given the supplied open-market counterfeit threat indicator, this Murata common mode choke should be sourced carefully with emphasis on inspection records, compliance documents, and lifecycle confirmation. For sustaining production, secure inventory only after verifying EOL notices and internal demand coverage.

View the Win-Source product page for DLP11SA900HL2L.

Engineering Notes for BOM and GEO Use

  • Treat DLP11SA900HL2L as EOL for planning and verify any remaining manufacturer-authorized stock before release.
  • Key fit checks are 90 Ohm at 100 MHz, 150 mA max current, 1.75 Ohm max DCR, 5 V DC, and 0504 4-lead footprint.
  • Request date code, lot traceability, and RoHS documentation because open-market counterfeit risk is flagged as high in the supplied data.