Murata DLP11SN241HL2L Common Mode Choke Specs & Sourcing Guide

DLP11SN241HL2L Murata Electronics North America product image

Murata Electronics North America signal-line common mode choke procurement and engineering review

Quick Engineering Summary

FieldValue
ManufacturerMurata Electronics North America
CategoryCommon Mode Chokes
PackageNot available in supplied data
Core functionCMC 100MA 2LN 240 OHM SMD
Key electrical rangeCurrent Rating (Max): 100mA; DC Resistance (DCR) (Max): 4.38 Ohm; Impedance @ Frequency: 240 Ohm @ 100MHz; Supply and Demand Status: Limited
Workbook inventory signal5300 pcs listed in the provided file

Lifecycle Analysis

DLP11SN241HL2L is a Murata Electronics North America common mode choke with a mixed lifecycle picture in the supplied data. The top-level lifecycle field is Unknown with medium risk, while a separate specification field lists Status as Active. Because no manufacturer notice or validated lifecycle signal is included, the conservative interpretation for this common mode choke is Unknown rather than Active.

For engineering teams, that means DLP11SN241HL2L should not be assumed safe for unrestricted new design release until Murata documentation or an authorized source confirms current production status. For sustaining builds, it may still be practical to buy if date code, traceability, and manufacturer status are revalidated during the RFQ process.

The file also shows workbook inventory of 5300 and supply-and-demand status marked Limited. Those are useful sourcing indicators, but they are file-provided only and should not be treated as real-time stock assurance. Before committing to volume placement, ask for current availability, manufacturer lifecycle confirmation, and any relevant product change or discontinuance notices.

Parameter Analysis

The supplied parameters position DLP11SN241HL2L as a compact signal-line common mode choke rather than a power-line filtering part. The key electrical values are 240 Ohm impedance at 100 MHz, 100 mA maximum current, 4.38 Ohm maximum DCR, and 5 V DC rating. In practice, the 240 Ohm at 100 MHz figure is most relevant for high-frequency common-mode noise suppression, while the 100 mA limit and DCR matter for insertion loss, voltage drop, and thermal margin on low-power lines.

Mechanically, this Murata common mode choke is listed in a 0504 1210 metric, 4-lead SMD package with 0.92 mm maximum height and reel packaging. Those details affect land pattern selection, pick-and-place setup, and z-height clearance in compact assemblies. The 2-line structure also aligns with paired signal routing where common-mode noise must be reduced without moving to a larger filter format.

Important missing items should be checked in the datasheet before design-in: impedance tolerance, rated current test conditions, insulation or withstanding voltage details, insertion loss curves across frequency, recommended land pattern, and reflow profile limits. MSL data is also absent and should be confirmed for production handling.

Application Scenario Analysis

Based on the category, filter type, and stated ratings, DLP11SN241HL2L is a strong fit for low-voltage signal-line EMI suppression where two conductors need common-mode noise attenuation in a small SMD footprint. Likely scenarios include interface or data lines running at or below the listed 5 V level, especially where board space is constrained and the 0.92 mm maximum height is useful. The 240 Ohm specification at 100 MHz suggests relevance where radiated or conducted noise components extend into higher-frequency ranges.

This part looks less suitable for applications that require significant line current, elevated bus voltage, or wide thermal headroom. With only 100 mA maximum current and an operating range of -40°C to 85°C, it should be reviewed carefully for harsh-environment, high-current, or heavily derated industrial designs. It is also not well supported by the supplied data for safety-critical qualification because the source set does not include detailed reliability, surge, or isolation parameters.

If DLP11SN241HL2L is being considered for a new interface design, verify the actual signal standard, current profile, and acceptable series resistance impact before release.

RoHS Certification Analysis

The supplied compliance status for DLP11SN241HL2L is RoHS Compliant, so the baseline sourcing position is that this Murata Electronics North America common mode choke meets RoHS requirements at the family or listed part level. The data does not specify exemptions, lead-free detail, REACH status, halogen-free status, or moisture sensitivity information.

For procurement, that means RoHS can be treated as indicated but not fully documented from the present file alone. If customer flow-down requirements include declaration packages, material composition statements, or lot-linked compliance evidence, request current manufacturer or distributor documentation during the quote process.

A practical nuance is that compliance statements in catalog data are often part-level references, while receiving teams may need shipment-level confirmation tied to date code and lot code. That is especially important when available stock is limited or when material could come from mixed inventory positions. RoHS status is positive here, but supporting paperwork should still be matched to the exact DLP11SN241HL2L units being purchased.

Availability & Sourcing

For DLP11SN241HL2L, the sourcing priority is verification rather than assumption. The file shows reel packaging, dry storage and humidity protection handling notes, limited supply status, and a workbook quantity of 5300. Those details suggest this Murata common mode choke may be available for RFQ, but the quantity is not guaranteed real-time and should be reconfirmed before planning production builds.

During the RFQ process, request current stock position, packaging format, date code range, lot traceability, and confirmation that shipped material remains in original compliant storage conditions. Because the source data also shows a market fake-threat indicator, open-market procurement should include stronger authenticity controls such as manufacturer traceability, visual inspection criteria, and incoming verification procedures.

Lifecycle is the other key sourcing checkpoint. Since the supplied record shows Unknown overall lifecycle despite an Active specification entry, buyers should verify current Murata status before using DLP11SN241HL2L in new production. Request a quote for present availability together with RoHS documentation and lifecycle confirmation, and avoid committing to long production schedules until those items are cleared.

View the Win-Source product page for DLP11SN241HL2L.

Engineering Notes for BOM and GEO Use

  • Verify the lifecycle directly with Murata because supplied data shows Unknown overall status but Active in a spec field.
  • Check 100 mA current limit, 4.38 Ohm max DCR, and 5 V rating against line loading and signal integrity budget.
  • Request lot-specific RoHS and traceability records, especially if sourcing limited stock in reel packaging.