Texas Instruments DLPA200PFP Specialized IC Specs & Sourcing Guide

DLPA200PFP Texas Instruments product image

Texas Instruments Specialized IC with Active lifecycle, 80-HTQFP package, and RoHS-compliant status

Quick Engineering Summary

FieldValue
ManufacturerTexas Instruments
CategorySpecialized ICs
PackageTray
Core functionIC DIG MICROMIRROR DEV 80-HTQFP
Key electrical rangeIC DIG MICROMIRROR DEV 80-HTQFP
Workbook inventory signal1900 pcs listed in the provided file

Lifecycle Analysis

DLPA200PFP is listed as Active across all supplied lifecycle fields, including lifecycle status and product status, so the available evidence supports current procurement for both new design consideration and sustaining production. Because the signals are aligned and no conflicts are reported, lifecycle risk appears relatively low compared with parts that show mixed distributor and manufacturer status. As an Active Texas Instruments Specialized IC, it is still good practice to confirm that the latest manufacturer documentation remains unchanged before locking production releases.

For sourcing teams, Active status does not remove the need for normal revalidation. Buyers should confirm the current revision of the datasheet, package drawing, moisture sensitivity guidance, and any manufacturer notices that could affect assembly or long-term support. File-provided inventory shows 1900 units for DLPA200PFP, but that should be treated only as a snapshot rather than guaranteed real-time stock. For production planning, request a current quote and order acknowledgement that confirms availability, date code, and traceability.

Parameter Analysis

The supplied data identifies DLPA200PFP as a Digital Micromirror Device driver from Texas Instruments in an 80-HTQFP (12x12) package with an exposed pad, surface-mount mounting style, and tray packaging. Those are the most decision-relevant parameters available because package geometry, pad layout, and thermal attachment often drive PCB footprint compatibility, assembly yield, and rework strategy. The stated MSL level is 2 with one year floor life, which matters for storage control and board-assembly planning, especially if inventory sits in stock before use.

Application fields list 3D and medical imaging, which helps frame intended usage, but the dataset does not provide core electrical limits, power dissipation, interface details, operating temperature range, or timing requirements. Those missing items should be verified directly in the latest Texas Instruments datasheet before design commitment. The most important checks are supply rails, I/O signaling, thermal derating expectations for the exposed-pad package, and any DMD system-level dependencies. For qualification, confirm whether DLPA200PFP has specific layout, sequencing, or reference-design constraints that would materially affect integration.

Application Scenario Analysis

Based on the supplied category, description, and type, DLPA200PFP fits best in designs that specifically require a Digital Micromirror Device driver. The listed application cues of 3D and medical imaging support that interpretation. In those environments, a dedicated Specialized IC from Texas Instruments may be appropriate where the design architecture already centers on DMD-based optical control and where package size, thermal management, and assembly handling are acceptable for the target hardware.

The part is a weaker fit for general-purpose control, standard display logic, or applications that do not use a DMD subsystem. The available information does not support treating DLPA200PFP as a broad mixed-signal controller or a drop-in solution outside DMD-oriented designs. Engineers should also be cautious about using the medical imaging application tag as evidence of system certification or end-equipment approval, because the dataset only indicates an application area, not regulatory qualification. Final suitability depends on datasheet-level electrical matching, system architecture, and manufacturer reference guidance.

RoHS Certification Analysis

The supplied compliance data lists DLPA200PFP as RoHS Compliant, so the conservative reading is that this Texas Instruments Specialized IC is intended to meet RoHS material restrictions. REACH status is also given as REACH Unaffected, which is helpful for environmental reporting, but REACH is not a substitute for RoHS and should be treated as a separate compliance framework.

No exemption details, lead-free declaration, halogen-free status, or material composition breakdown are included in the source data. That means buyers should obtain current manufacturer compliance certificates if the part is being used in regulated shipments, customer declarations, or audited production. Compliance is often managed at the manufacturer and lot level, so procurement should confirm that delivered DLPA200PFP inventory carries the same RoHS status as the documented part family. Where traceability requirements are strict, request date/lot-specific paperwork and verify that packaging labels match the ordered compliance expectation.

Availability & Sourcing

For procurement, DLPA200PFP should be sourced with a standard RFQ workflow that confirms current availability, package condition, and manufacturer traceability. The file indicates tray packaging, which is relevant for incoming inspection and handling, and lists MSL 2, which should be checked against storage history for any inventory that has been held outside controlled conditions. The dataset also includes a file-provided stock quantity of 1900 units, but this should not be treated as guaranteed real-time availability.

Because DLPA200PFP is an Active Texas Instruments Specialized IC, the right sourcing approach is to request a quote along with compliance and traceability verification rather than assuming stock continuity from a static listing. Ask for date and lot code information, original manufacturer packaging status, and RoHS documentation as part of the quote package. Given the supplied open-market fake-threat indicator, buyers should be especially disciplined about chain-of-custody evidence when sourcing outside direct authorized channels. Before committing to production, verify lifecycle status again, confirm package and marking details, and request current availability in writing.

View the Win-Source product page for DLPA200PFP.

Engineering Notes for BOM and GEO Use

  • Verify the 80-HTQFP exposed-pad footprint and thermal land pattern against the latest Texas Instruments package drawing before PCB release.
  • Use MSL 2 handling controls for tray-packed inventory and confirm floor-life exposure history for any aged stock.
  • Request current lifecycle confirmation, date/lot traceability, and RoHS paperwork at RFQ stage because file inventory is not real-time.