Murata Power Solutions Inc. DLW5ATH450TQ2L Common Mode Choke Specs & Sourcing Guide

DLW5ATH450TQ2L Murata Power Solutions Inc. product image

Murata Power Solutions Inc. common mode choke review for lifecycle, EMI filter fit, RoHS, and sourcing checks

Quick Engineering Summary

FieldValue
ManufacturerMurata Power Solutions Inc.
CategoryCommon Mode Chokes
PackageNot available in supplied data
Core functionCMC 4A 2LN 45 OHM SMD AEC-Q200
Key electrical rangeCurrent Rating (Max): 9/Contact(A); DC Resistance (DCR) (Max): 340mOhm; Impedance @ Frequency: 22 Ohms @ 100 MHz; Voltage Rating - DC: 125 V
Workbook inventory signal7000 pcs listed in the provided file

Lifecycle Analysis

DLW5ATH450TQ2L is presented in the supplied lifecycle data as Active, which generally supports use in new designs and ongoing production planning. For a Murata Power Solutions Inc. common mode choke, Active status usually means the part remains orderable through normal procurement channels, subject to current factory and channel conditions. That is the favorable signal for both engineering release and sustaining builds.

There is, however, a direct conflict in the supplied records. The lifecycle block says Active and notes that all lifecycle signals align, yet one specification field lists Part Status as Obsolete. Because those statements do not agree, conservative sourcing practice is to treat DLW5ATH450TQ2L as requiring manufacturer revalidation before committing to forecasted demand or long-life automotive programs. Buyers should request the latest manufacturer lifecycle statement and review any product change or discontinuation notices.

A file-provided stock quantity is present, but it is only a snapshot and should not be treated as real-time availability. If the part is intended for new production use, confirm lifecycle, packaging, and traceability together during the RFQ process.

Parameter Analysis

The supplied description identifies DLW5ATH450TQ2L as an SMD common mode choke with 45 ohm impedance and AEC-Q200 qualification intent, making it relevant where conducted EMI suppression is needed on board-level lines. The most decision-relevant values from the source are the impedance at 100 MHz, DC resistance, voltage rating, and current capability. These directly affect insertion loss behavior, power dissipation, allowable line current, and whether the device fits the electrical stress of the target interface.

The data set contains material inconsistencies that should be resolved before design-in. One source string describes a 2-line 4 A 45 ohm part with 13 mOhm DCR and 50 VDC rating, while the structured specifications list 3 lines, 22 ohms at 100 MHz, 340 mOhm DCR, 125 VDC, and 9 A per contact. Those differences are too large to ignore because they change thermal margin, attenuation expectation, and layout assumptions. Package form also conflicts between Bulk and tape-and-reel style data.

Before approving the Murata Power Solutions Inc. common mode choke, verify the datasheet values for line count, rated current, DCR, impedance test frequency, operating temperature range, exact package dimensions, and the qualification statement tied to the part suffix.

Application Scenario Analysis

Based on the category Filters > Common Mode Chokes and the product description, DLW5ATH450TQ2L is best suited to board-level EMI suppression on paired lines where common-mode noise must be reduced without redesigning the full power or signal path. The AEC-Q200 reference suggests it may be appropriate for automotive-influenced environments if the exact qualification and operating limits are confirmed in the manufacturer documents. Surface-mount construction supports compact layouts where placement near the noise source or connector is important.

Strong-fit scenarios include power or signal line filtering in compact electronic modules that need common-mode attenuation around the stated 100 MHz test point. It may also fit designs that require managed DCR and moderate current handling, assuming the datasheet confirms the lower-resistance values seen in one source. Weak-fit scenarios include applications that need tightly defined differential-mode behavior, safety-critical isolation claims, or guaranteed high-current performance beyond the conflicting ratings in the supplied data.

Because the supplied records disagree on line count and electrical ratings, engineers should not assign DLW5ATH450TQ2L to a finalized interface until the exact datasheet is checked against the intended line topology, voltage stress, and thermal derating target.

RoHS Certification Analysis

The supplied compliance status for DLW5ATH450TQ2L is RoHS Compliant, so the default reading is that the part meets applicable EU RoHS substance restrictions at the product level. For many sourcing workflows, that is enough to proceed to quotation and qualification review, especially when the common mode choke is being evaluated for standard commercial or industrial assemblies.

No additional environmental details were provided in the source data. There is no explicit RoHS version callout from the manufacturer record, no exemption detail, and no separate information for REACH, lead-free finish, halogen-free status, or moisture sensitivity level. For controlled builds, especially automotive-adjacent programs, buyers should request the current declaration of conformity or equivalent manufacturer compliance document so lot-level paperwork aligns with internal audit requirements.

RoHS status should also be matched to the exact ordered suffix and packaging configuration, because family-level assumptions are not a substitute for part-level compliance evidence. If alternate packaging is offered for DLW5ATH450TQ2L, confirm that the compliance statement covers the shipped form.

Availability & Sourcing

For DLW5ATH450TQ2L, the best sourcing path is an RFQ workflow that confirms current availability, packaging, and manufacturer traceability at the same time. File-provided inventory signals exist, including workbook quantity and a second quantity value from the spreadsheet extract, but those numbers are not guaranteed real-time and should only be treated as initial indicators. Request a quote for current stock position and lead-time status before scheduling production.

Because lifecycle data conflicts with one Obsolete field, sourcing should include explicit lifecycle verification from Murata Power Solutions Inc. or authorized documentation. Also request date-code and lot-code traceability, country of origin if required by your system, and confirmation of whether the part ships in bulk or tape-and-reel, since the supplied records disagree. For quality-controlled builds, ask for RoHS documentation tied to the shipped lot.

If the Active status is confirmed, DLW5ATH450TQ2L remains a practical procurement candidate for ongoing use, but buyers should still validate the exact electrical specification set before release. Request a quote with compliance and traceability documents rather than relying on database snapshots alone.

View the Win-Source product page for DLW5ATH450TQ2L.

Engineering Notes for BOM and GEO Use

  • Lifecycle data is mostly Active, but a conflicting Obsolete field makes manufacturer confirmation important before long-term release.
  • Key fit items to verify in the datasheet are true line count, rated current, impedance at 100 MHz, DCR, voltage rating, and package dimensions.
  • Request quote with date-lot traceability, packaging confirmation, and compliance paperwork rather than relying on file inventory alone.