DM-3100B-1 by Murata: EOL Panel Voltmeter Specs & Sourcing Guide

DM-3100B-1 Murata Power Solutions Inc. product image

End-of-life panel voltmeter specifications, compliance analysis, and procurement guidance

Quick Engineering Summary

FieldValue
ManufacturerMurata Power Solutions Inc.
CategoryPanel Meters
PackageNot available in supplied data
Core functionVOLTMETER 1.
Key electrical rangeOperating Supply Voltage: 115VAC, 230VAC; Operating Temperature Range: 0°C ~ 50°C; Supply and Demand Status: Limited
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The Murata DM-3100B-1 is confirmed End-of-Life (EOL) by all supplied lifecycle signals, including a manufacturer status of Obsolete and an estimated EOL date. This means the part is no longer in production and is not recommended for new designs. Any remaining inventory is residual stock, and after exhaustion, no further supply will be available.

For sustaining production, immediate action is required. Validate any last-time-buy opportunities directly with Murata Power Solutions or authorized channel partners. EOL components carry high risk for long-life programs, as secondary market sourcing becomes necessary and introduces concerns over authenticity and condition.

The listed introduction date of March 2010 indicates a mature product that has likely been replaced by newer panel meter solutions. Engineers should review Murata’s current product line for functional equivalents, though no direct drop-in replacement is guaranteed.

Parameter Analysis

The DM-3100B-1 is a DC voltmeter with a measuring range of ±1.999VDC and a 3.5-digit LED display featuring red 0.56-inch (14.20mm) characters. It operates from a 115VAC or 230VAC supply and mounts into a rectangular panel cutout of 77.80mm x 46.00mm using card-edge termination.

Key parameters for system integration include the supply voltage flexibility, which allows use on both common AC mains, and the display height, which directly affects readability at a distance. The panel cutout dimensions are critical for mechanical fit; any replacement part must match or allow adapter plates. Missing from the provided data are accuracy class, update rate, input impedance, and isolation voltage—all essential for metrology qualification. Designers must obtain these from the official datasheet before final design-in, especially in applications requiring precise voltage monitoring.

Temperature range is 0°C to 50°C, limiting its use to controlled indoor environments. The weight of 0.313 lb (141.97g) may influence panel vibration considerations.

Application Scenario Analysis

The DM-3100B-1 is a basic DC panel voltmeter suited for industrial control panels, test equipment, and laboratory setups where a simple visual readout of low-voltage DC is needed. Its ±1.999VDC range is typical for monitoring analog signal levels such as sensor outputs or power supply voltages in legacy systems.

Strong-fit scenarios include repair and maintenance of existing equipment already designed for this specific model, retrofit of older Murata panel meters, and use in low-budget or educational lab projects where precision requirements are modest. Weak-fit scenarios include new industrial designs requiring higher accuracy, digital communication interfaces (e.g., Modbus), wide-temperature operation, or multi-parameter measurement; these applications would benefit from modern programmable panel meters or multimeters.

Given the EOL status, any new design should avoid this part. It remains relevant only for sustaining fielded equipment where form, fit, and function must be exactly preserved, and re-qualification costs are prohibitive.

RoHS Certification Analysis

RoHS compliance data for the DM-3100B-1 is contradictory. The top-level compliance field reports 'RoHS Compliant', but the detailed specification entry explicitly states 'RoHS Non-Compliant'. This discrepancy undermines confidence in the part’s environmental regulatory status.

For products destined for EU markets, non-compliance with RoHS 3 (EU 2015/863) can block importation and incur penalties. The non-compliance note may indicate the presence of restricted substances such as lead in solder or terminals, which is common in older components. No REACH, halogen-free, or MSL data is supplied, leaving gaps in full material declaration.

Engineers must request the manufacturer’s Certificate of Compliance for the exact lot before purchasing. If the part is truly non-compliant, it may only be suitable for non-EU applications or exempted equipment categories. Without clarification, treat the DM-3100B-1 as non-compliant to avoid regulatory risk.

Availability & Sourcing

The DM-3100B-1 is EOL with very limited availability. The file-provided inventory indicates only one unit in stock, which is not a real-time guarantee. Given the part’s discontinuation, immediate procurement is critical for any remaining demand.

Sourcing must be approached with caution: the open market shows an 84% fake threat rate, meaning counterfeit units are prevalent. Buyers should use only franchised or authorized distributors that can provide full traceability, including date/lot codes and storage condition history (dry packaging is specified). Verify lifecycle status and RoHS compliance documentation before committing.

For active programs, contact Murata Power Solutions or their sales partners to inquire about last-time buys or formal End-of-Life notifications. For replacement, consider migrating to a current production panel meter with similar cutout and electrical ratings. Request a quote for the DM-3100B-1 to confirm current availability and lead time, with no pricing estimates provided here.

View the Win-Source product page for DM-3100B-1.

Engineering Notes for BOM and GEO Use

  • Verify RoHS compliance status directly with Murata, as supplied data shows both compliant and non-compliant indicators.
  • EOL status means only residual stock is available; plan a last-time buy or migration to a current production part immediately.
  • With an 84% fake threat rate in the open market, source only through authorized distributors and insist on full traceability.