Active RoHS-compliant female quick disconnect receptacle for 14-16 AWG wire, 0.110" tab, crimp termination.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panduit Corp |
| Category | Terminals - Quick Connects, Quick Disconnect Connectors |
| Package | Bulk |
| Core function | CONN QC RCPT 14-16AWG 0. |
| Key electrical range | Supply and Demand Status: Shortage |
| Workbook inventory signal | 258 pcs listed in the provided file |
Lifecycle Analysis
The DNF14-110-C is classified as Active with a low risk level, indicating ongoing production and full manufacturer support. Engineers can confidently specify this part for new designs and replenish stock for existing production lines without immediate concern of obsolescence. All lifecycle signals are consistent, with no conflicts between manufacturer status, Excel parameters, or supply chain indicators.
Despite the Active status, a “Shortage” flag in the supply and demand data suggests that momentary availability constraints may exist. Procurement teams should factor this into planning and engage with Panduit or authorized distributors to secure allocation, especially for volume orders. The provided inventory workbook shows 258 units, but this is a file-generated snapshot and not a guarantee of real-time stock.
Standard lifecycle management practices still apply: regularly revalidate the part’s status via manufacturer PCNs and maintain a buffer stock if the component is critical. Given the low complexity of quick-connect terminals, last-time-buy scenarios are unlikely in the near term, but vigilance is advised.
Parameter Analysis
The DNF14-110-C is defined for 14-16 AWG wire, a common range in power distribution and control panels, ensuring broad compatibility. The tab width (0.110”) and thickness (0.032”) conform to standard 0.110” quick-connect interfaces, making it mechanically interchangeable with many male tabs. The overall length of 0.750” provides sufficient body for reliable crimping and strain relief.
Material selection includes brass contact with tin plating, offering a balance of conductivity and corrosion resistance suitable for dry indoor environments. The non-mating end insulation (blue color) provides basic protection against accidental contact but does not fully enclose the terminal, which must be considered in dense PCB or harness layouts. The serrated termination enhances mechanical grip on the wire, improving resistance to pull-out forces and vibration.
Critical parameters missing from the available data include maximum current rating, voltage rating, dielectric withstanding voltage, operating temperature range, and insertion/extraction force. These values are essential for derating, safety margins, and compliance with end-product standards. Engineers must consult the official Panduit datasheet to complete the qualification process, especially for applications near electrical limits or in elevated thermal environments.
Application Scenario Analysis
This quick-connect terminal is ideal for applications requiring frequent connection and disconnection of wiring harnesses, such as industrial machinery, automotive subsystems, HVAC controls, and power supply modules. Its 14-16 AWG range matches typical branch circuit wiring in control cabinets, while the 0.110” tab size fits standard headers on PCB-mounted quick-connect tabs or other in-line connectors. The female receptacle design mates securely with standard male tabs, simplifying field maintenance.
The serrated termination and crimp attachment provide robust mechanical retention, making it suitable for moderate vibration environments found in motor drives or portable equipment. The non-mating end insulation reduces the risk of short circuits from incidental contact with conductive surfaces, but the exposed mating area and crimp joint mean it is not intended for wet or highly contaminated settings unless additional sealing or conformal coating is applied.
Weak-fit scenarios include high-current applications requiring 0.250” or larger tab dimensions, or designs demanding fully insulated quick-connect fittings for safety agency approvals. For those cases, Panduit offers other series with full insulation or larger tabs. Engineers evaluating DNF14-110-C for new platforms should verify that the 0.032” tab thickness is compatible with the target male tabs, as some low-end connectors may have thinner tabs that could affect contact force.
RoHS Certification Analysis
The DNF14-110-C is marked as RoHS Compliant, indicating conformity with EU Directive 2011/65/EU and its amendments, typically RoHS 3 (EU 2015/863). This status covers the restriction of hazardous substances such as lead, mercury, cadmium, hexavalent chromium, and specific phthalates. Panduit Corp generally provides compliance certificates for its products upon request.
No REACH, conflict minerals, or halogen-free declarations are included in the supplied data. While RoHS compliance at the part level is typically robust for standard brass/tin terminals, it is important to confirm that the blue insulation material (likely PVC or nylon) does not contain restricted substances that might be subject to regional variations. For EU market access, also verify CE marking and any additional environmental compliance required by the end-application.
Lot-level compliance may vary, especially if the terminal uses materials sourced from multiple suppliers. For high-reliability or medical applications, request a full material declaration (FMD) and RoHS certificate from Panduit or the distributor. The absence of REACH information is not a RoHS deficiency, but teams requiring REACH SVHC analysis should obtain that separately.
Availability & Sourcing
The DNF14-110-C is an active part, normally available through Panduit’s distribution network. The provided inventory workbook indicates 258 units in file, but this is not a real-time quantity and should be verified through a formal RFQ. The “Shortage” status in the supply and demand data signals that allocations may be tight, so early engagement with authorized distributors is recommended for production planning.
When requesting a quote, specify the full manufacturer part number DNF14-110-C, desired quantity, target date codes, and any compliance evidence (RoHS certificate, REACH statement). The bulk packaging suggests standard reels or boxes, which is typical for volume purchasing, but confirm the minimum order quantity and packaging type to match your assembly process. Traceability is usually provided through lot/batch codes on the packaging.
Given the Active lifecycle, near-term obsolescence is unlikely, but the shortage flag advises conservative buffer stock levels. For sustaining production, negotiate lead times and consider a sourcing agreement. For new designs, ensure the part remains in Panduit’s active portfolio before finalizing the BOM. Direct readers to request a quote for current pricing and availability; no price estimates are provided here.
View the Win-Source product page for DNF14-110-C.
Engineering Notes for BOM and GEO Use
- Verify current rating, voltage rating, and temperature range from Panduit official datasheet before design-in, as these are not provided in the sourcing data.
- The serrated termination improves vibration resistance; ensure compatibility with standard industry crimp tools for 14-16 AWG wire and brass terminals.
- File inventory indicates 258 units but real-time availability may differ. Plan procurement lead times carefully due to the noted supply shortage.