Panduit DNF18-111FIB-M Terminal Specs & Sourcing Guide

DNF18-111FIB-M Panduit Corp product image

Pan-Term® female quick-connect receptacle, 18-22 AWG, 0.110" x 0.020" tab, fully insulated crimp terminal for in-line wiring applications.

Quick Engineering Summary

FieldValue
ManufacturerPanduit Corp
CategoryTerminals
PackageBulk
Core functionCONN QC RCPT 18-22AWG 0.
Key electrical rangeNot available in supplied data
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The lifecycle status of the DNF18-111FIB-M could not be determined from available signals. Without a manufacturer-confirmed Active, NRND, EOL, or Discontinued status, design teams should exercise caution for new production. The absence of official lifecycle data does not imply immediate obsolescence, but it introduces risk for sustaining procurement.

File-provided inventory shows only a single unit, which is not a reliable indicator of market availability. This part may be subject to last-time buys or limited distribution without notice. Buyers should request Panduit or authorized distributors to provide a current Product Change Notice (PCN) or product road map. Until lifecycle is verified, avoid reliance on this part for long-life programs without second-source planning or buffer stock.

For design qualification, treat the part as unconfirmed. If the end application requires production longevity, parallel qualification of an alternative terminal with a clear Active status is recommended.

Parameter Analysis

The DNF18-111FIB-M is a standard, fully insulated female quick-connect terminal. Key parameters include tab dimensions (0.110" width, 0.020" thickness), which must match the mating male tab for a secure mechanical and electrical connection. The wire range of 18-22 AWG and maximum insulation diameter of 0.120" (3.05 mm) define the crimp envelope; exceeding these may lead to poor strain relief or insulation damage.

Contact material is brass with a tin finish, offering a balance of conductivity and corrosion resistance for general-purpose applications. The serrated termination feature enhances wire grip during crimping. Red insulation color follows industry convention for 18-22 AWG terminals, aiding assembly inspection. Overall length of 0.710" provides sufficient space for handling without being overly bulky in tight enclosures.

Critical missing datasheet values include temperature rating, voltage rating, current carrying capacity, and insulation material. Engineers must verify these from the official Panduit Pan-Term® datasheet or product specification before finalizing design. Crimp tool and die set specifications are also essential for reliable production assembly.

Application Scenario Analysis

This terminal is a strong fit for internal wiring harnesses in appliances, industrial control panels, and HVAC equipment where 18-22 AWG discrete wires need a reliable, quick-connect interface. The fully insulated design reduces the risk of accidental shorting in dense wiring areas. It suits applications requiring serviceability without frequent disconnection, such as motor connections, transformer leads, and sensor wiring.

In automotive aftermarket or low-vibration environments, the tin-plated brass contact and serrated termination provide adequate mechanical retention. However, for high-vibration or high-cycle uses, this terminal may require additional strain relief, as it is a standard disconnect rather than a high-retention or positive-lock design. Its lack of an environmental seal limits use to indoor or protected enclosures unless housed within a sealed connector body.

Avoid in circuits where current exceeds typical 18-22 AWG ampacity without thermal verification. The terminal’s performance at elevated temperatures is not documented in the supplied data, so derating and in-situ testing are necessary for high-power or safety-critical circuits.

RoHS Certification Analysis

DNF18-111FIB-M is listed as RoHS Compliant, satisfying the European Union's Restriction of Hazardous Substances (RoHS) directive. The REACH status is Unaffected, which addresses chemical substance regulations but does not substitute for RoHS certification. MSL Level is Not Applicable, as is typical for passive interconnect components without moisture-sensitive packaging.

While the RoHS status is declared, no certification date or compliance test reports are provided in the available data. For CE-marked or RoHS-controlled products, procurement teams should request a current RoHS certificate from Panduit or the distributor. Lot-level verification ensures that the actual shipment meets the claimed compliance, especially when sourcing from non-authorized channels.

RoHS exemptions, if any, are not shown; given the tin contact finish, Pb-free conditions are expected. To meet EU 2015/863 (RoHS 3), verify that the insulation material and any internal plastic components do not contain legacy phthalates or other restricted substances.

Availability & Sourcing

DNF18-111FIB-M is supplied in bulk packaging with a standard package quantity of 1,000, simplifying inventory for moderate-volume production. The file-provided inventory shows a single unit, but this does not reflect guaranteed real-time stock. Interested buyers should request a quote for current availability, lead time, and minimum order quantities from authorized Panduit distribution.

The open-market fake threat level is reported as 54%, indicating a significant risk of counterfeit or substandard parts from unauthorized sources. To mitigate this, always purchase through franchised distributors or directly from Panduit, and require full traceability documentation including date codes, lot codes, and RoHS compliance certificates.

Given the unknown lifecycle status, sourcing should begin with a lifecycle verification step. If the part is confirmed Active, proceed with standard RFQ and compliance checks. If NRND, secure sufficient inventory for the production run and evaluate migration to a recommended replacement. If EOL or Discontinued, last-time buy opportunities must be explored immediately. For any status, insist on manufacturer-backed supply rather than relying on open-market brokers.

View the Win-Source product page for DNF18-111FIB-M.

Engineering Notes for BOM and GEO Use

  • Verify crimp tool compatibility; Panduit specifies dedicated tools for Pan-Term® terminals to ensure gas-tight crimps and avoid insulation damage.
  • Confirm wire range and insulation diameter: 18-22 AWG with max insulation diameter 0.120" (3.05 mm). Oversized insulation may prevent full insertion.
  • Lifecycle status is not publicly confirmed; obtain a manufacturer PCN or EOL notice before committing to production volumes or new designs.