Panduit DNF18-187-C Quick Disconnect Terminal Specs & Sourcing Guide

DNF18-187-C Panduit Corp product image

Female, 18-22 AWG, 0.187 Inch Tab, Red Insulated Crimp Terminal

Quick Engineering Summary

FieldValue
ManufacturerPanduit Corp
CategoryTerminals - Quick Connects, Quick Disconnect Connectors
PackageBulk
Core functionCONN QC RCPT 18-22AWG 0.
Key electrical rangeSupply and Demand Status: Shortage
Workbook inventory signal35 pcs listed in the provided file

Lifecycle Analysis

The DNF18-187-C is currently listed as Active by Panduit, with all available lifecycle signals aligned and no conflicts. This status indicates that the part is in full production and fully supported for both new designs and ongoing production builds. Engineers can proceed with incorporating the DNF18-187-C into new projects, provided standard procurement practices are followed.

However, even a low-risk Active part should be periodically revalidated against the manufacturer’s official product change notifications (PCN) and end‑of‑life notices. The file-provided inventory snapshot shows 35 units, but this is not a live stock figure and should not be relied upon for production planning. Always request a current quote to confirm real‑time availability and lead times.

Parameter Analysis

Key parameters for the DNF18-187-C center on its wire compatibility and mating interface. It accepts 18–22 AWG wire, a common range for signal and low‑power applications, and uses a crimp termination that requires properly matched tooling for a reliable connection. The 0.187-inch (4.75 mm) tab width and 0.032-inch (0.81 mm) tab thickness define the receptacle’s mating envelope; incorrect tab dimensions can lead to poor contact or mechanical failure.

Additional important features include the red insulation on the non‑mating end, which provides visual identification and basic electrical isolation. The tin‑plated brass contact offers good conductivity and corrosion resistance for dry indoor environments. The serrated termination enhances wire retention in the crimp joint. Parameters not available from the supplied data include current rating, voltage rating, operating temperature range, and insulation material. These must be verified against the official Panduit datasheet before design finalization to ensure safe operation within the intended circuit.

Application Scenario Analysis

The DNF18-187-C is a strong fit for internal wiring in appliances, industrial control panels, and automotive harnesses where a quick‑disconnect female terminal mates with a standard 0.187-inch male tab. Its 18–22 AWG wire range suits moderate current paths such as sensor connections, relay coils, and control signal wiring. The red insulation often corresponds with industry color‑coding conventions for this wire size, aiding assembly and service.

These terminals are less suitable for applications with high vibration unless additional strain relief or secondary locking is provided. They are not rated for direct outdoor exposure or wet environments unless protected by a sealed enclosure. For high‑current circuits exceeding typical 22–18 AWG ampacity, a larger terminal series would be needed. Engineers should also confirm that the mating tab on the host connector matches the specified 0.187-inch width and 0.032-inch thickness to avoid mismatched engagement forces.

RoHS Certification Analysis

Panduit Corp declares the DNF18-187-C as RoHS Compliant, meaning it meets the requirements of the EU Restriction of Hazardous Substances Directive. For a tin‑plated brass terminal with plastic insulation, this typically involves restrictions on lead, mercury, cadmium, hexavalent chromium, and certain flame retardants (PBBs/PBDEs). No specific exemption details are supplied, suggesting the component falls within standard, non‑exempted material declarations.

While the RoHS status covers a key environmental compliance requirement, it does not substitute for REACH or other region‑specific regulations. If your product requires a full material declaration or REACH statement, you must request that directly from Panduit or the distributor. For high‑reliability industries, it is also advisable to obtain lot‑specific compliance certificates to ensure traceability and batch conformity.

Availability & Sourcing

The DNF18-187-C remains an Active part from Panduit, allowing procurement through authorized distribution channels. The file‑provided quantity of 35 pieces is indicative only and does not guarantee real‑time inventory; it is a snapshot that may change without notice. To obtain current stock levels, pricing, and lead times, you must submit a request for quotation (RFQ) to Win‑Source or your preferred distributor.

The supplied data indicates a supply status of 'Shortage', suggesting that lead times may be extended. Plan orders accordingly and consider buffer stock if the DNF18-187-C is critical for production. Always confirm lifecycle status at the time of order and request compliance documentation (RoHS certificate, date/lot code traceability) when lead‑time or regulatory requirements demand it. For high‑volume needs, ask the distributor about full reel or bulk packaging availability to optimize handling and cost.

View the Win-Source product page for DNF18-187-C.

Engineering Notes for BOM and GEO Use

  • Verify wire gauge compatibility and crimp tooling prior to production to ensure a gas‑tight, reliable termination.
  • Match mating tab dimensions (0.187×0.032 inch) exactly to prevent intermittent contact or mechanical stress.
  • Confirm insulation material and temperature rating against application environment from the manufacturer datasheet.