Specifications, lifecycle status, compliance, and procurement guidance for Panduit Corp part DNF18-187FIB-C.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panduit Corp |
| Category | Terminals - Quick Connects, Quick Disconnect Connectors |
| Package | Bulk |
| Core function | CONN QC RCPT 18-22AWG 0. |
| Key electrical range | Supply and Demand Status: Shortage |
| Workbook inventory signal | 2597 pcs listed in the provided file |
Lifecycle Analysis
The DNF18-187FIB-C is listed as Active by Panduit Corp, meaning it is in full production and recommended for new designs as well as sustaining procurement. This status is supported by multiple lifecycle signals from the manufacturer and distributor. There are no conflicting lifecycle indications.
Engineers integrating this quick disconnect terminal can expect stable availability, but should note that a supply‑and‑demand flag indicates a shortage condition. While the workbook shows 2597 units on file, this is not guaranteed real‑time inventory. For production planning, verify current stock and lead‑times directly with an authorized distributor.
Given the Active status and low risk level, no immediate migration planning is required. However, for long‑term programs, consider second‑source qualifications to mitigate future supply interruptions.
Parameter Analysis
Key specifications for the DNF18-187FIB-C include tab width (0.187 inch / 4.75 mm), wire gauge range (18-22 AWG), crimp termination, fully insulated nylon housing in red, and a serrated brass contact with tin plating. The tab width is critical for mating with compatible male tabs; it must match the receptacle or tab on the mating connector. The 18-22 AWG range dictates crimp tool and die selection, directly impacting electrical and mechanical reliability.
The serrated termination feature enhances vibration resistance by providing multiple bite points into the wire strands. Full insulation offers short‑circuit protection and meets common safety standards. The 0.780 inch overall length and free‑hanging mounting style suit inline splicing applications.
Parameters not specified in the supplied data include current rating, voltage rating, insulation temperature rating, dielectric withstand, and pull‑force specifications. These must be verified against the official Panduit datasheet before finalizing board layout or system design. For high‑current or elevated‑temperature environments, confirm that the tin‑plated brass contact and nylon body meet derating requirements.
Application Scenario Analysis
DNF18-187FIB-C is well‑suited for typical quick‑disconnect applications in appliances, industrial control panels, automotive harnesses, and power tools. The 18-22 AWG wire range aligns with many internal signal and low‑power distribution circuits. The red color coding conventionally matches 22-18 AWG, aiding visual assembly inspection. The fully insulated design allows use in crowded panels where accidental contact must be prevented.
Strong‑fit scenarios include field‑serviceable connections that benefit from easy disconnect, such as motor leads, sensor wiring, and battery terminals. The serrated contact improves retention in moderate vibration environments, making it appropriate for machinery and vehicle subsystems.
Weak‑fit scenarios involve applications exceeding the standard tab current capacity (not provided) or where operating temperature nudges beyond nylon insulation limits. Blind‑mating without visual alignment may also reduce reliability; additional strain relief or connectors with positive locks should be considered for high‑reliability designs. Procurement teams should confirm actual current and temperature ratings before specifying this terminal for outdoor or harsh‑environment use.
RoHS Certification Analysis
The DNF18-187FIB-C is reported as RoHS Compliant. This indicates it meets European Union restrictions on lead, mercury, cadmium, hexavalent chromium, PBBs, and PBDEs, and likely the four phthalates under RoHS 3 (EU 2015/863). However, the exact directive revision is not specified in the supplied data.
For formal compliance documentation, request a manufacturer’s declaration or test report referencing the applicable RoHS directive and listing any exemptions. Components with red nylon insulation sometimes use brominated flame retardants; verify that these are not restricted under the relevant standard. REACH status should also be confirmed separately, as RoHS does not cover all SVHCs.
For full traceability, specify that lot‑level certificates are required with each shipment. This is especially important for export or regulated industries. In the absence of explicit exemption notes, treat the part as fully compliant per the manufacturer’s statement, but re‑validate with the latest technical datasheet.
Availability & Sourcing
DNF18-187FIB-C is an Active part from Panduit Corp, supplied in bulk packaging. The workbook indicates 2597 units on file and a shortage status, so inventory may be constrained. Buyers should request a current quote to obtain real‑time availability, lead‑times, and minimum order quantities.
Specify part number DNF18-187FIB-C clearly in RFQs to avoid confusion with similar quick‑disconnect variants. Request traceability information including date/lot codes, especially when ordering for regulated or high‑reliability applications. Verify that the packaging condition (bulk) suits your assembly process; if tape‑and‑reel is needed, confirm alternates with the manufacturer.
Since the lifecycle is Active, standard procurement channels are likely capable of sourcing this terminal. However, given the shortage signal, it is prudent to seek confirmation of stock allocation before committing to production schedules. Ask for RoHS and REACH compliance documentation alongside the commercial quote to streamline incoming quality control.
View the Win-Source product page for DNF18-187FIB-C.
Engineering Notes for BOM and GEO Use
- Confirm crimp tool and die part numbers for consistent termination quality on 18-22 AWG wire.
- Specify lot-level RoHS and REACH compliance documents during RFQ to ensure batch traceability.
- Assess mechanical retention with serrated contact for vibration-prone designs; request pull-force test data if critical.