Active 0.250 inch female quick connect terminal, fully insulated, red, 18-22 AWG, crimp termination.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panduit Corp |
| Category | Terminals - Quick Connects, Quick Disconnect Connectors |
| Package | Bulk |
| Core function | CONN QC RCPT 18-22AWG 0. |
| Key electrical range | Supply and Demand Status: Shortage |
| Workbook inventory signal | 133 pcs listed in the provided file |
Lifecycle Analysis
The Panduit DNF18-250FI-L is classified as Active with a low risk level. All supplied lifecycle signals align, indicating the part is in sustained production and fully supported by the manufacturer. This means it is suitable for both new design-in and ongoing sustaining production without immediate concerns of obsolescence.
Despite the active status, engineers should establish a periodic re-validation cadence, especially for long-lifecycle programs. While no conflicts exist in the provided data, always confirm with Panduit directly for any upcoming EOL notices, particularly if the component is being used in high-reliability or regulated applications.
The file-provided inventory quantity of 133 units offers a snapshot of current availability but is not guaranteed in real-time. For production planning, treat this as a reference only and query live stock before placing orders.
Parameter Analysis
Key parameters for the DNF18-250FI-L include a wire range of 18-22 AWG, a tab width of 0.250 inches (6.35 mm), and tab thickness of 0.032 inches (0.81 mm). The terminal type is standard female with crimp termination, and it features full insulation in red. Overall length is 0.940 inches (23.88 mm), and it mounts free-hanging in-line. Contact material is brass with a tin finish.
These specifications determine mating compatibility and termination performance. The 0.250-inch tab is a common quick-connect size, but engineers must ensure the mating male tab thickness matches the 0.032-inch receiver. Wire gauge acceptance directly impacts current-carrying capacity; however, the datasheet should be consulted for derating curves and maximum current rating, as these are not supplied. The insulation type and temperature rating are also missing—critical for thermal management.
For PCB-free designs, confirm insulation resistance and dielectric strength. Tin-plated brass offers good conductivity and corrosion resistance at a moderate cost, but for high-vibration environments, consider additional locking features not specified here.
Application Scenario Analysis
The DNF18-250FI-L fits well in quick-connect/disconnect applications requiring a reliable, insulated female terminal for 18-22 AWG wire. Typical strong-fit scenarios include internal wiring in appliances, industrial control panels, HVAC equipment, and automotive harnesses where periodic disconnection is needed. The fully insulated design and color-coded red insulation aid in circuit identification and provide basic electrical isolation.
Weak-fit scenarios may include extremely high-temperature environments above the insulation rating (unknown from provided data) or high-vibration applications without secondary locking. The crimp termination requires proper tooling; inconsistent crimp quality could lead to intermittent connections. Also, for outdoor or washdown environments, verify if the insulation and tin plating offer adequate protection; sealing may be necessary.
Given the unspecified insulation material, do not assume resistance to chemicals or UV unless verified. For safety-critical circuits, supplemental retention features are recommended.
RoHS Certification Analysis
The DNF18-250FI-L is declared RoHS Compliant according to the supplied data. This indicates that the part meets the European Union’s Restriction of Hazardous Substances directive. However, the exact revision (e.g., RoHS 2 (2011/65/EU) or RoHS 3 (2015/863)) is not specified. For full compliance assurance, especially in EU market products, request the manufacturer’s certificate of compliance that details the tested directive and any exemptions.
The data does not include REACH, halogen-free, or MSL ratings. REACH compliance is a separate regulatory requirement; if needed, verify separately. Lot-level compliance can vary; thus, for regulated industries, insist on batch-specific documentation.
As a single component, the DNF18-250FI-L’s RoHS status is typically inherent in the materials (brass, tin, insulation), but confirmation from Panduit is a standard procurement step.
Availability & Sourcing
The DNF18-250FI-L is an active part with a supply-and-demand status of ‘Shortage’, according to the provided data. This suggests that while in production, allocation may be limited. The file-provided inventory shows 133 units, but this is a snapshot and not a real-time guarantee. Engineers and buyers should request a current quote to confirm lead time and stock levels.
Sourcing from authorized distribution is recommended to ensure traceability and full manufacturer warranties. For active components, standard procurement practices apply: specify date and lot codes if needed for traceability, confirm packaging (bulk), and validate lifecycle status at the time of order. The part’s compliance documentation (RoHS, CoC) should be requested with the quote.
Given the shortage indication, consider securing inventory for critical builds and evaluating second sources or alternative manufacturers for risk mitigation. Do not commit to high-volume new designs without a confirmed supply outlook from Panduit or authorized distributors.
View the Win-Source product page for DNF18-250FI-L.
Engineering Notes for BOM and GEO Use
- Verify crimp tooling compatibility with Panduit recommended dies to ensure reliable gas-tight terminations.
- Confirm insulation material and temperature rating from the official datasheet; nylon is common but not specified here.
- The supply-and-demand status indicates shortage; account for potential lead times when planning production volumes.