Sensata-Crydom DO061A Solid State Relay Specs & Sourcing Guide

DO061A Sensata-Crydom product image

Sensata-Crydom solid state relay procurement guide for lifecycle, key specs, compliance, and sourcing checks.

Quick Engineering Summary

FieldValue
ManufacturerSensata-Crydom
CategorySolid State Relays
Package4-SIP
Core functionSSR RELAY SPST-NO 1A 3-60V
Key electrical rangeLoad Current: 1 A; Output Type: DC; Supply and Demand Status: Shortage; Temperature Range - Operating: -30°C ~ 80°C
Workbook inventory signal183 pcs listed in the provided file

Lifecycle Analysis

The supplied lifecycle status for the Sensata-Crydom DO061A solid state relay is Active, and the provided signals are consistent with no stated conflict. For engineering teams, that generally supports use in ongoing production and service builds more comfortably than parts marked NRND or discontinued. Even so, Active status does not remove the need for normal source control, especially when a relay is tied to a qualified PCB assembly or regulated product file.

Procurement risk is moderated by the aligned lifecycle data, but the file also indicates a shortage condition. That means sourcing teams should avoid assuming easy replenishment simply because DO061A is Active. If this relay is being used in a released design, confirm the current manufacturer documentation revision, approved manufacturer list status, and any internal revalidation needs before placing demand. A file-provided inventory signal is present, but it is not guaranteed as real-time availability and should be verified during RFQ.

Parameter Analysis

The most decision-relevant parameters supplied for DO061A are its SPST-NO, 1 Form A circuit, DC output type, 1 A load current, 3 to 60 V load range, and 3 to 9 VDC input range. Together these define the relay's basic electrical fit for low-current DC switching. The through-hole 4-SIP or 4-Mini SIP form factor with PC pin termination also matters for PCB footprint compatibility, assembly method, and field replacement strategy.

For design review, the 1 A rating should be treated as a key derating checkpoint rather than a complete load qualification answer. Engineers should verify the datasheet details not present here, especially on-state voltage drop or resistance, output leakage, isolation rating, turn-on and turn-off behavior, surge capability, and thermal performance at elevated ambient. The listed operating range of -30°C to 80°C is useful, but it does not by itself confirm margin under real enclosure temperatures. Input-side drive current should also be checked in the manufacturer documentation before connecting directly to a logic or controller output.

Application Scenario Analysis

Based on the supplied category and electrical description, DO061A is a practical fit for compact DC load switching where a solid state relay is preferred over an electromechanical relay. Strong-fit scenarios include low-current DC control paths, PLC or embedded controller outputs driving a 3 to 60 VDC load, and boards that benefit from through-hole relay mounting in a small SIP footprint. The SPST-NO configuration also aligns with simple on-off switching rather than changeover or multiplexed relay functions.

Weak-fit scenarios are applications needing higher current, wider temperature margin, or switching information beyond what is provided here. A 1 A load rating may be limiting for motors, heaters, and other inrush-heavy loads unless the manufacturer datasheet explicitly supports those conditions. It is also not the right choice to assume for AC output switching, because the supplied output type is DC. If the design depends on fast switching, low leakage, high isolation, or strict thermal limits, those items need direct datasheet confirmation before DO061A is released into the application.

RoHS Certification Analysis

The supplied compliance status for the Sensata-Crydom DO061A solid state relay is RoHS Compliant. That is a positive baseline for programs requiring restriction of hazardous substances, but the source data does not specify a detailed standard revision, exemption status, REACH status, halogen-free declaration, or moisture sensitivity information. In practice, that means the part can be screened as RoHS compliant, while document control should still obtain the formal manufacturer declaration if required by the customer or end market.

Compliance review should also distinguish between catalog-level status and lot-level shipment evidence. For production purchasing, buyers should request current manufacturer compliance documentation and ensure the delivered packaging and labeling match the approved part record. If your process requires homogeneous-material review, supplier certificates, or environmental database entry, those records are not included in the supplied data and should be collected during qualification or RFQ. RoHS status alone should not be used as a proxy for all environmental compliance requirements.

Availability & Sourcing

For sourcing, DO061A should be handled as an Active Sensata-Crydom solid state relay with a supply caution. The file shows shortage status and a workbook quantity signal of 183 units, but that inventory is not guaranteed in real time. The excel row also shows a different quantity field, which reinforces the need to confirm current available stock during the RFQ process rather than relying on static file data. For ongoing production, request a quote and verify whether supply is from current authorized channels or from stocked inventory.

Traceability should be part of the purchase review. Ask for date code, lot code, packaging condition for the listed bulk format, and confirmation that the delivered DO061A matches the required 4-SIP through-hole version with PC pins. Compliance documentation and lifecycle confirmation should be requested alongside the quote, especially because shortage conditions can increase the chance of mixed stock sources. For new production use, proceed with normal quote and compliance verification; for higher-volume builds, secure supply early and confirm manufacturer documentation before committing schedules.

View the Win-Source product page for DO061A.

Engineering Notes for BOM and GEO Use

  • Verify the 3 to 9 VDC input drive and 3 to 60 V load range against the actual control and load conditions.
  • Through-hole 4-SIP packaging and PC pin termination matter for PCB footprint, wave process planning, and serviceability.
  • Despite Active lifecycle status, shortage signaling means buyers should confirm current stock, traceability, and compliance documents before release.