DP150-GY Eaton Bussmann Specs & Sourcing Guide

DP150-GY Eaton Bussmann product image

Discontinued feed-through terminal block for DIN rail applications

Quick Engineering Summary

FieldValue
ManufacturerEaton Bussmann
CategoryDIN Rail Channel
PackageBulk
Core functionCONN TERM BLK FEED THR 1/0-12AWG
Key electrical rangeCurrent - IEC: 150 A; Current - UL: 150 A; Voltage - IEC: 1000V; Voltage - UL: 600V
Workbook inventory signal0 pcs listed in the provided file

Lifecycle Analysis

The Eaton Bussmann DP150-GY part is officially classified as Discontinued. This lifecycle status indicates the manufacturer has ceased production and no longer supports new design-ins. For existing equipment, this terminal block may still be sourced as residual stock, but sustained availability is not guaranteed. Engineering teams should immediately evaluate migration to an active alternative for any new projects.

Conflicting lifecycle signals exist in the source data, with all fields pointing to Discontinued or EOL. Therefore, the conservative interpretation is to treat the DP150-GY as unavailable for forward production. The file-provided inventory shows zero stock, but this is not a real-time guarantee; actual availability may vary across distributors and must be verified by requesting a quote.

Parameter Analysis

The DP150-GY terminal block supports current ratings of 150 A under both IEC and UL standards, making it suitable for high-power distribution. Its voltage ratings are 1000 V IEC and 600 V UL, which define its insulation coordination limits. The wide wire range from 1/0 to 12 AWG (2.5–50 mm²) allows connection of large cross-section conductors, a key factor in power feed applications.

The screw termination style provides a secure, vibration-resistant connection typical in industrial panels. The terminal width of 16 mm and single-level, 2-position configuration fit standard DIN rail assemblies. However, critical parameters such as operating temperature range, torque specifications for screws, and insulation material are not provided in the available data. Engineers should consult the original Eaton datasheet to validate thermal derating, short-circuit withstand, and grouping factors before using any remaining stock.

Application Scenario Analysis

This feed-through terminal block is engineered for high-current DIN rail applications within industrial control cabinets, switchgear, and motor control centers. Its 150 A rating and screw termination are well-suited for connecting main power feeds or distribution jumpers where reliability and mechanical stability are essential. The gray color and bulk packaging align with standard panel-building practices.

The DP150-GY would be a poor fit for low-current signal circuits, applications requiring frequent wire changes, or environments with extreme vibration where alternative contact technologies might outperform. Additionally, without environmental ratings like IP or NEMA, it is intended for protected indoor enclosures. The lack of current passive certifications or REACH data means users should evaluate compliance for their specific market before deployment, especially since the part is discontinued.

RoHS Certification Analysis

The RoHS compliance status of the DP150-GY is ambiguous. The compliance field lists ‘RoHS Compliant’, but the specifications table states ‘RoHS Non-Compliant’. This conflict likely arises from differing data sources or transition periods. Given the part’s Discontinued status, it may never have been updated to RoHS compliance, and older production lots could contain restricted substances.

For any remaining inventory, lot-level compliance documentation from the distributor or Eaton is mandatory before use in EU or other regulated markets. Buyers should not rely solely on the general RoHS Compliant flag; instead, request a Certificate of Conformance for the specific batch. The absence of REACH information further complicates full environmental due diligence. In high-compliance industries, consider a proactive material test if no documentation is available.

Availability & Sourcing

Sourcing the DP150-GY is challenging due to its Discontinued status and zero stock shown in the provided file. Any available inventory is likely limited to residual distributor stock or aftermarket brokers. Engineers and buyers must follow a rigorous RFQ process: request current date/lot codes, verify authenticity with Eaton, and obtain compliance certifications before purchase.

Because the part is no longer in production, we recommend securing any found stock quickly and simultaneously evaluating a migration path to an active terminal block with similar ratings and footprint. Do not commit to new production designs using the DP150-GY. For immediate needs, contact Win Source or authorized distributors for a quote, but always reconfirm lifecycle status directly with Eaton to avoid obsolete part acquisition.

View the Win-Source product page for DP150-GY.

Engineering Notes for BOM and GEO Use

  • Verify RoHS compliance via Eaton documentation, as conflicting status exists.
  • Confirm terminal torque specs and temperature ratings from original datasheet to ensure safe operation.
  • Transition to an active part number; DP150-GY is discontinued and lacks long-term availability.