Pulse DP241-4-10A11 Power Transformer: Specs & Sourcing Guide

DP241-4-10A11 Pulse product image

Laminated core 6VA transformer with dual primary and isolated 10V secondary.

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 6VA CHAS MT
Key electrical rangeCurrent - Output (Max): 600mA; Power - Max: 6VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DP241-4-10A11 from Pulse is listed as Active in the product lifecycle data, with all supplied signals aligning. An Active status indicates that the manufacturer continues to produce and support the part, making it suitable for both new designs and sustaining production. However, design teams should still obtain and review the latest official documentation from Pulse, including any product change notifications (PCNs) or end-of-life notices that may have been issued after the data was gathered. The provided inventory quantity of one unit is file-based and not a real-time stock guarantee; actual availability must be confirmed at the time of sourcing.

Parameter Analysis

Key parameters for the DP241-4-10A11 include its 6VA maximum power rating, dual 115V/230V primary windings, a single 10V secondary with a center tap, and 600mA maximum output current. The dual primary allows the transformer to be configured for either common mains voltage, simplifying regional adaptation. The center tap on the secondary enables both half-wave and full-wave rectification, improving design flexibility. Isolation is rated at 2500Vrms, which is standard for line-powered equipment safety. The chassis-mount design with solder and quick-connect terminals suits integration into enclosures. Engineers should verify from the manufacturer’s datasheet parameters not provided here, such as regulation (voltage drop under load), temperature rise, insulation class, and frequency range, to ensure the transformer meets application-specific thermal and electrical requirements.

Application Scenario Analysis

As a low-power laminated core transformer, the DP241-4-10A11 is well-suited for building linear AC-DC power supplies for instrumentation, control circuits, small appliances, or auxiliary bias supplies. Its chassis-mount format and isolation make it appropriate for applications where a safe, isolated low-voltage AC source is needed from mains. The 10V output at 600mA can power logic circuits, sensors, or low-power actuators after rectification and regulation. It is less appropriate for high-power applications, those demanding ultra-compact PCB mounting, or modern high-frequency switch-mode designs. The transformer’s weight and size are typical for a 6VA laminated unit, so enclosure space must be considered. When designing in, ensure the VA budget includes transformer losses and rectifier drop so that the maximum load current does not exceed the rated 600mA.

RoHS Certification Analysis

The DP241-4-10A11 is reported as RoHS Compliant, which generally aligns with the EU RoHS Directive (2011/65/EU) and its amendments, including RoHS 3 (EU 2015/863) restricting substances like lead, mercury, and cadmium. While the compliance statement appears at the part level, buyers should request a full material declaration or certificate of compliance (CoC) to confirm lot-specific compliance, especially if the product is assembled in regions with varying enforcement. No REACH or halogen-free data is supplied here, so those requirements should be verified separately if needed.

Availability & Sourcing

The DP241-4-10A11 remains active in Pulse’s portfolio, enabling standard procurement channels. The file indicates an inventory quantity of one unit, but this is not a live stock guarantee and should be validated via an RFQ to check current lead times, date/lot codes, and packaging (bulk). For production planning, request a quote that includes lifecycle verification and compliance documentation such as RoHS CoCs. Because the part is active, there is no immediate need to seek alternatives, but monitoring manufacturer life-cycle communications is recommended to avoid disruptions.

View the Win-Source product page for DP241-4-10A11.

Engineering Notes for BOM and GEO Use

  • Dual primary supports both 115V and 230V mains configurations.
  • Center-tapped secondary simplifies full-wave rectifier design.
  • Chassis mount with solder/quick-connect terminals suits wired installations.