Comprehensive specs, lifecycle, and procurement information for Pulse DP241-6-28A36.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 30VA CHAS MT |
| Key electrical range | Current - Output (Max): 1.1A; Power - Max: 30VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
All available lifecycle indicators for the Pulse DP241-6-28A36 show the part as Active, with no conflicting signals. Active status indicates the component is in full production, recommended for both new designs and ongoing manufacturing. For new designs, engineers can confidently incorporate this transformer, but should still verify the latest lifecycle status directly with Pulse or an authorized distributor, especially for high-volume or long-lifecycle programs, as manufacturer roadmaps can change.
The supplied inventory workbook lists a single unit, which is a file-based snapshot and not guaranteed to reflect real-time availability. Buyers should not rely on this quantity for immediate sourcing decisions. For sustaining production, consider standard lead times and plan buffer stock accordingly; for new designs, ensure that the active lifecycle aligns with your product’s expected lifetime.
Parameter Analysis
The DP241-6-28A36 from Pulse is a laminated core power transformer with a dual primary (115V/230V) and a single secondary that provides 28V at full load, rated for up to 1.1A current, yielding a maximum apparent power of 30.8 VA, just above the 30VA max rating—so thermal management at full load should be considered. The center tap on the secondary enables full-wave rectification with a simple two-diode configuration, saving component count. The high-voltage isolation of 2500Vrms is critical for safety in line-powered applications; verify that your end-product standards require this level of isolation, and consider clearance and creepage distances in your PCB or chassis layout.
Mechanical parameters include chassis mounting with solder or quick-connect terminals, dimensions of 82.55mm x 49.28mm footprint and 42.93mm height, and a weight of 1.1 lbs. These directly affect enclosure design, vibration resistance, and assembly process. Missing from the listed specs are regulation percentage, no-load voltage, efficiency, and frequency range. Engineers should obtain the full datasheet to verify regulation under expected load variation, as laminated transformers typically have poorer regulation than toroidal types, and to confirm operation at your line frequency (likely 50/60 Hz).
Application Scenario Analysis
This transformer fits best in linear power supply designs needing a robust, isolated 28V rail with moderate current, such as in bench power supplies, battery chargers, or analog instrumentation. The dual primary supports worldwide AC line voltages, so it is suitable for universal input equipment, while the center tap simplifies bipolar supply creation. Its chassis mount and generous isolation make it appropriate for enclosed equipment where safety isolation is paramount.
It is less suitable for high-frequency switching converters, where its laminated core would incur high losses, or for applications requiring low profile or PCB integration, since the 42.93mm height and chassis mount preclude direct board mounting. For audio applications, the 30VA rating might serve small preamplifiers or effect pedals, but the lack of electrostatic shielding could result in noise coupling; consider an additional shield if low noise is critical. Overall, verify actual load regulation does not cause excessive voltage drop in sensitive circuits.
RoHS Certification Analysis
The DP241-6-28A36 is listed as RoHS Compliant, which indicates it meets the substance restrictions under the EU RoHS directive. This status typically applies to the entire component family, but compliance can vary by production lot, so requesting a current RoHS certificate with each order is advisable, especially for products destined for the EU market. The supplied data does not specify which version of RoHS it meets (e.g., RoHS 3 2015/863), so confirm with the manufacturer or distributor that it complies with the latest directive applicable to your product.
No REACH or halogen-free declarations are provided in the source data, but these may be available upon request. Since this is a transformer with wire, insulation, and possibly potting compounds, it's important that all homogeneous materials comply. For high-reliability applications, consider adding a compliance audit clause to your procurement specification to cover evolving environmental requirements.
Availability & Sourcing
The DP241-6-28A36 is an active product from Pulse, so standard distribution channels should carry it, but actual lead times and stock levels fluctuate. The attached workbook indicates one unit in file inventory, which is not a real-time guarantee; use it only as a reference. To procure, submit an RFQ to win-source or other authorized distributors, specifying desired quantity, required date, and compliance documentation needs.
Request a formal quote that includes manufacturer part number verification, date code range, packaging type (bulk), and RoHS compliance certificate. Given the active lifecycle, there is no immediate need to secure last-time buys, but for production programs, negotiate lead times and consider safety stock. For design qualification, obtain samples with traceable lot codes to validate electrical and mechanical parameters against your requirements. Always confirm that the distributor is authorized to ensure traceability and avoid counterfeit risks.
View the Win-Source product page for DP241-6-28A36.
Engineering Notes for BOM and GEO Use
- Verify center tap configuration matches your rectifier topology; 28V full-load secondary at 1.1A gives 30.8VA, close to max rating, so ensure adequate cooling and derating.
- Dual primary windings support 115V and 230V inputs; confirm wiring before powering to avoid damage, and check regulation under load from the datasheet.
- Chassis mount, bulk packaging, and 42.93mm height require mechanical integration planning; request lot-specific RoHS certificate when ordering.