DP241-7-48A48 Pulse 56VA Laminated Core Transformer Sourcing Guide

DP241-7-48A48 Pulse product image

56VA laminated core power transformer with dual primary, single secondary, center tap, and chassis mount. Active lifecycle, RoHS compliant.

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 56VA CHAS MT
Key electrical rangeCurrent - Output (Max): 1.2A; Power - Max: 56VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V
Workbook inventory signal0 pcs listed in the provided file

Lifecycle Analysis

The DP241-7-48A48 is currently in Active lifecycle status, as confirmed by multiple sources within the Pulse product database. This means the part is fully supported for both new designs and ongoing production, with no immediate risk of discontinuation. All available lifecycle signals align, indicating a stable supply position.

For engineers and buyers, an active status allows standard procurement planning without urgent last-time buys. However, it is still advisable to request a product roadmap or lifecycle forecast from Pulse or authorized distributors when designing the part into long-lifecycle programs. The supplied inventory workbook shows zero units, but this is a file-based snapshot and does not guarantee real-time stock levels. Actual availability must be confirmed via quote.

In summary, DP241-7-48A48 presents low procurement risk. Sustaining production should include periodic revalidation of lifecycle status, especially if the transformer is critical to system function. No alternate part numbers or suggested replacements were provided, so if a future EOL occurs, a custom search would be necessary.

Parameter Analysis

The DP241-7-48A48 is specified with key parameters that dictate its fit in power supply designs. The 56VA maximum power rating, combined with a 48V secondary at 1.2A, defines the output capability. Engineers must consider derating for elevated ambient temperatures, as no temperature rise data is supplied. The dual primary (115V and 230V) enables worldwide mains compatibility, and the single secondary with center tap supports full-wave rectification configurations.

Mechanical parameters are critical for chassis-mount integration: length 93.73mm, width 57.15mm, and seated height 45.97mm. The solder and quick-connect terminations offer flexibility, but designers should verify pad/hole sizes and current-carrying capacity. The 2500Vrms isolation rating provides a safety margin for line-to-low-voltage isolation, but the insulation class (e.g., Class B, F) is not stated and must be obtained from the full datasheet to ensure thermal endurance.

Important missing specifications include regulation, efficiency, no-load losses, and temperature rise. These values are essential for estimating thermal performance and voltage drop under load. Before finalizing the design, request the official Pulse datasheet to confirm these parameters and ensure compatibility with regulatory safety standards.

Application Scenario Analysis

The DP241-7-48A48 laminated core transformer is well-suited for linear AC-DC power supplies, industrial control systems, instrumentation, and audio equipment where a step-down from mains to a low-voltage rail is required. Its 48V secondary at 1.2A can supply power to analog circuits, relay coils, or motor drivers that accept unregulated DC after rectification. The center tap allows bipolar supply generation when needed.

Because it is a line-frequency (50/60 Hz) transformer, it is not appropriate for high-frequency switching converters or compact DC-DC modules. The chassis-mount construction and 1.7 lb weight assume fixed installations rather than portable or space-constrained devices. In applications with high inrush current or intermittent overloads, verify that the transformer can handle the peak currents without excessive temperature rise.

This part is a strong candidate for replacement or new designs in legacy industrial equipment that still uses linear power supplies. However, if size and weight are critical, engineers should consider alternative technologies such as SMPS, which are beyond the scope of this component.

RoHS Certification Analysis

The DP241-7-48A48 is listed as RoHS Compliant in the source data. This indicates that it meets the EU Restriction of Hazardous Substances directive, typically RoHS 3 (EU 2015/863) for current production. No specific exemptions are mentioned, which suggests general compliance without special material exemptions. However, for formal qualification, a full material declaration or certificate of compliance from Pulse should be obtained.

Because RoHS status can be lot-dependent, especially for older inventory, it is important to request documentation for the specific date codes received. The supplied data does not include REACH information, so if full chemical compliance is required, a separate inquiry is necessary. REACH compliance is not a substitute for RoHS certification.

For procurement, specifying RoHS compliance on the purchase order and requesting the manufacturer's test report helps ensure consistent compliance. This is particularly relevant when the component will be used in products sold in the EU or other regions with similar regulations. The active lifecycle suggests that ongoing production continues to meet current environmental standards.

Availability & Sourcing

The DP241-7-48A48 is an active Pulse power transformer, and as such, it should be available through authorized distributors with standard lead times. The file-provided inventory quantity shows zero, but this does not represent live stock. To obtain current availability, request a quote through your preferred channel, specifying the part number and required quantity.

When sourcing, include compliance and traceability requirements: date code, lot code, RoHS certificate, and country of origin. Since the transformer is shipped in bulk packaging, attention should be paid to handling and storage conditions to avoid damage to terminals or insulation. For production runs, consider vendor-managed inventory or blanket orders to secure allocation given the part’s active status and potential demand.

Because no alternate parts are indicated, and the lifecycle is active, the primary focus should be on price and delivery negotiations. If the part were to transition to NRND or EOL in the future, alternative sources or custom magnetics would need to be evaluated. For now, DP241-7-48A48 can be quoted and ordered with typical active-component procurement processes.

View the Win-Source product page for DP241-7-48A48.

Engineering Notes for BOM and GEO Use

  • Verify isolation voltage withstand capability and creepage/clearance distances for your specific safety certification requirements.
  • Evaluate worst-case temperature rise and derating at maximum VA load in the intended enclosure to ensure reliable operation.
  • Confirm mechanical footprint, mounting hole pattern, and termination style compatibility with your PCB or chassis wiring before finalizing the design.