Pulse DP241-8-16A53: 100VA Laminated Core Transformer – Chassis Mount, Dual Primary, 16V/6.25A Output.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 100VA CHAS MT |
| Key electrical range | Current - Output (Max): 6.25A; Power - Max: 100VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Workbook inventory signal | 0 pcs listed in the provided file |
Lifecycle Analysis
The DP241-8-16A53 from Pulse is listed as Active in the supplied lifecycle data, with no conflicting signals. This status indicates that the manufacturer continues to produce and support the part, making it suitable for new design-ins and volume production. For procurement stability, engineers should verify the manufacturer’s long-term roadmap and any planned discontinuance notices, especially if targeting multi-year product lifecycles.
Risk level is assessed as low given the aligned Active indications. However, as with any electronic component, it is prudent to confirm current stock and lead times with authorized distributors. The file-provided inventory shows zero quantity, which is not real-time data; actual availability must be requested via RFQ.
Parameter Analysis
Key specifications from the available data include a maximum power rating of 100VA, dual primary windings for 115V or 230V operation, and a single 16V secondary at full load with a 6.25A maximum output current. The transformer features a center tap on the secondary, which is valuable for bipolar power supply designs using full-wave rectification. Isolation is rated at 2500Vrms, an important safety parameter for line-operated equipment.
Mechanical characteristics include chassis-mount assembly with solder and quick-connect terminals, dimensions of 102.36mm x 65.02mm and a seated height of 57.15mm, with a weight of 2.8 lbs (1.3 kg). The laminated core construction is typical for 50/60 Hz low-frequency power conversion. Critical missing data from the provided specs include thermal class, temperature rise, efficiency, no-load losses, and winding resistances. These parameters are essential for derating, thermal management, and voltage regulation analysis. Engineers should obtain the full Pulse datasheet to verify these values before finalizing the design.
Application Scenario Analysis
The DP241-8-16A53 is well-suited for linear AC-DC power supplies in industrial controls, instrumentation, battery charging circuits, and audio equipment where a traditional laminated core transformer with chassis mounting is acceptable. The dual primary enables use in both 115V and 230V mains systems without reconfiguration, and the center-tapped secondary simplifies the design of positive and negative voltage rails.
This transformer is less appropriate for high-frequency switching power converters, PCB-mount applications requiring low profile, or designs where weight and high efficiency are critical constraints. Its size and weight make it best for stationary equipment with adequate enclosure space. Users should plan for external rectification, filtering, and protection components. Verify that the 6.25A secondary current rating and 100VA power capacity match your load requirements, including inrush and peak currents during start-up.
RoHS Certification Analysis
The DP241-8-16A53 is marked as RoHS Compliant in the provided data, which typically indicates compliance with EU Directive 2015/863 (RoHS 3). No specific exemption details are supplied. Given the part is a power transformer, exemptions related to lead in solders or high-temperature materials might apply under certain categories, but these are not documented here.
For full compliance assurance, particularly for CE marking or similar regulatory filings, request a manufacturer’s certificate of compliance (CoC) for the specific lot. REACH status is not provided, so a separate declaration should be obtained if required. Lot-level verification is recommended because compliance status can vary with production changes or material substitutions over time.
Availability & Sourcing
The DP241-8-16A53 comes in bulk packaging and uses solder and quick-connect terminations. File-provided stock quantity shows zero, which should not be interpreted as current inventory. Since the lifecycle is Active, the part should be available through Pulse’s authorized distribution network with standard lead times.
To secure supply, issue a request for quote (RFQ) that includes the exact part number and request date/lot codes, packaging condition, and RoHS compliance documentation. For production planning, confirm the continuation of Active status directly with the manufacturer or an authorized distributor and consider the implications of long-term component availability. Do not rely on published stock counts without verification, as real-time levels may change rapidly.
View the Win-Source product page for DP241-8-16A53.
Engineering Notes for BOM and GEO Use
- Verify primary and secondary winding resistances and temperature rise from the full datasheet to accurately model voltage drop and thermal margin under load.
- Use the center tap for a full-wave rectifier configuration to reduce ripple and improve transformer utilization, but ensure the 2500Vrms isolation meets safety requirements for your application.
- Confirm chassis mounting hole spacing and mechanical clearance, as the transformer’s weight (2.8 lbs) may require additional support in high-vibration environments.