Laminated Core | 100VA | 28V Secondary | Dual Primary | Chassis Mount | Active
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 100VA CHAS MT |
| Key electrical range | Current - Output (Max): 3.6A; Power - Max: 100VA; Voltage - Isolation: 2500Vrms; Voltage - Primary: 115V, 230V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DP241-8-28A56 is currently in active production according to Pulse, with all available lifecycle signals indicating Active status. This means the transformer is fully supported for new designs and can be sourced for ongoing production without immediate risk of discontinuation. Engineers designing in the DP241-8-28A56 should still obtain formal lifecycle documentation from Pulse for long-term program commitments, as status can evolve. A file-provided inventory quantity of 1 unit is noted, but this is not a real-time guarantee and should be verified with a distributor.
For sustaining production, active lifecycle status simplifies procurement and allows for standard lead-time planning. However, it is advisable to periodically revalidate directly with Pulse or authorized channels, as supply chain conditions can impact availability. The lack of conflicting lifecycle signals reinforces confidence that the DP241-8-28A56 remains a stable part for industrial power applications.
Parameter Analysis
Key parameters of the DP241-8-28A56 include its 100VA power rating, 28V secondary at 3.6A full load, and dual primary windings for 115V or 230V operation. The laminated core construction and chassis-mount form factor suit linear, low-frequency applications. The center tap on the secondary allows for full-wave rectification with two diodes or a dual-polarity supply design. The 2500Vrms isolation voltage is typical for line-powered equipment and ensures galvanic separation.
Important missing datasheet details include regulation percentage (how much secondary voltage drops from no-load to full-load), efficiency, and temperature rise under rated load. These affect thermal management and output voltage accuracy. Engineers should verify these values on the official Pulse datasheet before finalizing PCB layout and enclosure design. The 102.36mm x 65.02mm footprint and 57.15mm height must be accommodated, and the 2.8lbs weight may require mechanical support.
Application Scenario Analysis
The DP241-8-28A56 is well-suited for linear power supplies in industrial controls, test equipment, and audio amplifiers where 28V DC rails are required after rectification. Its 100VA rating can deliver approximately 2.5–3A after rectification losses, depending on filter capacitor configuration. The dual primary makes it adaptable to global mains voltages, and the chassis-mount design facilitates convection cooling in open-frame installations.
Weak-fit scenarios include high-frequency switch-mode power supplies where ferrite core transformers are preferred, or portable battery-powered applications due to its weight and size. It is also not ideal for applications requiring very tight load regulation without post-regulation, as laminated transformers have inherent droop. Verify the full-load secondary voltage and regulation characteristics to ensure compatibility with downstream regulators.
RoHS Certification Analysis
Pulse describes the DP241-8-28A56 as RoHS Compliant, indicating conformance to EU Directive 2011/65/EU and likely including the stricter RoHS 3 (EU 2015/863) amendment. As a laminated transformer, potential exemptions may apply to lead in solders for internal connections if high-reliability exemptions are invoked, though typically new designs use lead-free terminations. The provided data does not specify REACH or halogen-free status; these should be confirmed if required by project specifications.
RoHS compliance is often declared at the product family level, and lot-specific certifications may be available upon request. For high-volume production or regulated markets, it is prudent to obtain the manufacturer's Declaration of Conformity and verify that the exact lot purchased meets all applicable environmental standards. The DP241-8-28A56's RoHS status helps avoid restrictions in EU market access.
Availability & Sourcing
As an active part, the DP241-8-28A56 is expected to be available through authorized Pulse distributors and catalog distributors. Standard packaging is bulk, and lead times can vary based on manufacturing schedules. Buyers should request a quote for current pricing and lead time, as availability is subject to change. A file-provided stock quantity of 1 unit was noted, but this is not a real-time inventory; always confirm with the supplier.
When sourcing, verify lifecycle status, lot and date codes for traceability, and request RoHS compliance documentation. For production orders, consider negotiating scheduled deliveries to manage lead time risk. The chassis-mount transformer's bulk packaging means adequate handling precautions during shipping. Given the active lifecycle, there is no immediate need for last-time buys, but planning for long-term requirements with Pulse is advisable.
View the Win-Source product page for DP241-8-28A56.
Engineering Notes for BOM and GEO Use
- Verify secondary voltage regulation curves from the datasheet to ensure adequate headroom for downstream regulators under full load.
- Account for the transformer's 2.8 lbs weight and dimensions in mechanical design; ensure chassis reinforcement if needed.
- Confirm isolation voltage safety margin relative to your application's overvoltage category and working voltage requirements.