DP4018N2M Artesyn 18V 40W Adapter Specs & Sourcing Guide

DP4018N2M ARTESYN / Advanced Energy product image

Discontinued Artesyn adapter; verify lifecycle, check RoHS compliance, request quote for remaining inventory.

Quick Engineering Summary

FieldValue
ManufacturerARTESYN / Advanced Energy
CategoryAC DC Desktop, Wall Adapters
PackageBag
Core functionAC/DC DESKTOP ADAPTER 18V 40W
Key electrical rangeCurrent - Output (Max): 2.22A; Input Connector: IEC 320-C8; Input Type: Cord (Sold Separately); No Load Power Consumption: 300mW (Max)
Workbook inventory signal102 pcs listed in the provided file

Lifecycle Analysis

The DP4018N2M from Artesyn / Advanced Energy is officially listed as Discontinued. Conflicting lifecycle signals—EOL and Discontinued—appear in the source data, requiring a conservative sourcing approach. This means the DP4018N2M is no longer recommended for new design projects. Engineers should consider it only for limited sustaining production where no immediate alternative exists.

Existing inventory of 102 units is file-provided and does not guarantee real-time stock; actual availability must be confirmed with the supplier. Before using this part, contact the manufacturer to obtain a formal Product Change Notification (PCN) and verify the final lifecycle status. Any procurement should include date/lot code verification to avoid obsolete or non-conforming stock.

Parameter Analysis

The DP4018N2M desktop adapter delivers a 18 V output at up to 2.22 A (40 W maximum) from a universal AC input of 90 to 264 VAC. Output is via a barrel plug with 2.5 mm inner diameter, 5.5 mm outer diameter, and 9.5 mm length, with positive center polarization. These dimensions and polarity must match the device’s DC jack exactly to avoid interconnect failure.

Efficiency meets Level V standards, and no-load power consumption does not exceed 300 mW. Operating temperature range is limited to 0°C to 40°C, which restricts use to indoor, climate-controlled environments. The adapter's form factor is Desktop (Class II), requiring an IEC 320-C8 cord (sold separately). The documentation does not list critical parameters such as output ripple and noise, line/load regulation, holdup time, isolation voltage, or immunity to surges. Engineers should request the full datasheet to assess these factors and confirm that protection mechanisms (OVP, OCP, SCP) are adequate for the intended load.

Application Scenario Analysis

The DP4018N2M is rated for ITE (Commercial) and Medical applications, supported by CB and CE certifications. It is well suited for powering small medical instruments, commercial monitors, point-of-sale terminals, or communication devices that need a regulated 18 V supply at up to 2.22 A, especially where a desktop adapter is preferred for ease of replacement.

However, its 0°C to 40°C operating range makes it unsuitable for outdoor equipment, high-temperature industrial machinery, or any environment subject to condensation. Medical applications require additional verification of IEC 60601-1 compliance for isolation and leakage current; the adapter’s classification as Class II and approvals may not be sufficient on their own. The adapter’s international input and Level V efficiency suit global deployment, but the limited stock and discontinued status make it impractical for scaling production.

RoHS Certification Analysis

The DP4018N2M carries a compliance tag stating 'RoHS Compliant', but one specification table row lists 'RoHS Non-Compliant'. This contradiction must be resolved before procurement. The safest interpretation is that the part was originally designed to meet EU RoHS requirements, but some batches or documentation may not guarantee full compliance.

Buyers should obtain a certificate of compliance (CoC) and full material declarations (FMD) from the distributor or manufacturer for the specific lot. The part does not list REACH data, so a separate REACH declaration should also be requested if needed. No exemptions are documented. Due to the part’s obsoletion, verifying environmental compliance at the lot level is essential to avoid regulatory risk.

Availability & Sourcing

The DP4018N2M is a high-risk, discontinued component. File-provided data indicates a stock of 102 units, but this is not a real-time guarantee. Potential buyers must submit a request for quote to check current availability, pricing, and lead time. Stock is supplied in Bag packaging; request date/lot codes to ensure traceability and to avoid counterfeit or reclaimed units.

Given the part’s obsolete status, secure inventory only after verifying manufacturer PCN documents and compliance certifications. Evaluate an immediate migration to a recommended alternative from Artesyn or a third party if this part is intended for production. For one-time repairs or bench use, small quantities may be sourced from brokers, but all date codes and RoHS status must be validated.

View the Win-Source product page for DP4018N2M.

Engineering Notes for BOM and GEO Use

  • Obtain manufacturer Product Change Notification (PCN) to confirm final lifecycle and compliance status, as conflicting RoHS signals exist.
  • Validate barrel plug dimensions (2.5mm I.D. x 5.5mm O.D.) and polarization (positive center) against device receptacle to prevent mechanical mismatch.
  • Review thermal derating and efficiency curves in full datasheet to ensure reliable operation within 0–40°C ambient range, especially for enclosed medical equipment.