Discontinued 2-position feed-through terminal block for DIN rail, 41A IEC, yellow.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Eaton Bussmann |
| Category | DIN Rail Channel |
| Package | Bulk |
| Core function | CONN TERM BLK FEED THRU 8-20 AWG |
| Key electrical range | Current - IEC: 41 A; Current - UL: 45 A; Voltage - IEC: 500V; Voltage - UL: 600V |
| Workbook inventory signal | 0 pcs listed in the provided file |
Lifecycle Analysis
The DP45-YW from Eaton Bussmann is listed as Discontinued according to multiple lifecycle signals in the provided data. The Excel lifecycle parameter shows EOL, Lifecycle Status is marked Discontinued, and Product Status is Discontinued. This consensus indicates the part is no longer manufactured and should not be used in new designs. For existing equipment, it may be procured only for maintenance, repair, or limited production runs where no redesign is feasible.
Engineers must verify the manufacturer's official discontinuation notice and end-of-life schedule to assess support timelines. Given the high risk level, procurement teams should seek stock from authorized distributors or remaining channel inventory, though reported workbook quantity is zero. Do not rely on this part for volume production or long-term availability without securing sufficient stock.
Parameter Analysis
Key parameters for DP45-YW include its feed-through terminal block type, screw termination, and ratings: 41 A IEC, 45 A UL current, 500 V IEC, 600 V UL voltage. Wire range spans 8–20 AWG (0.5–6 mm²), suitable for typical industrial conductors. The 8.0 mm terminal width and single level with 2 positions fit standard DIN rail layouts. Yellow color aids identification. These specs are decision-relevant for current-carrying capacity, voltage withstand, and conductor compatibility.
However, critical datasheet details are missing, such as insulation material temperature rating, flammability classification, screw torque, and pollution degree. Engineers must obtain the full datasheet to verify derating curves, short-circuit withstand, and environmental limits. The conflicting RoHS status (both compliant and non-compliant listed) adds uncertainty that must be resolved before integration into systems requiring environmental compliance. Additionally, confirm the enclosure and creepage/clearance distances align with system safety standards.
Application Scenario Analysis
The DP45-YW is a feed‑through terminal block designed for DIN rail mounting in industrial control panels, switchgear, and power distribution. Its 41 A IEC rating suits power distribution for feed-through connections where wires up to 20 AWG are used. Typical strong‑fit applications include motor control center wiring, I/O terminations, and panel internal power routing. The screw clamp termination provides reliable wire retention in stationary equipment.
Weak‑fit scenarios involve high‑vibration environments where screw terminals may loosen, or applications requiring frequent wiring changes where push‑in style might be preferred. Yellow color could indicate special voltage or functional identification per control panel standards. Because this part is discontinued, its application is limited to exact replacement in existing designs; new projects should avoid it. Also, verify voltage rating against system requirements: 600 V UL, 500 V IEC may not suffice for higher‑voltage equipment.
RoHS Certification Analysis
The compliance signal for DP45-YW is contradictory: the top‑level RoHS status says RoHS Compliant, but the specifications table lists RoHS Non‑Compliant. This conflict must be resolved before use in regulated markets. If truly compliant, it likely meets EU RoHS directive restrictions on lead, mercury, and other hazardous substances. However, without explicit certification or a valid declaration from Eaton Bussmann, assume non‑compliance until verified.
Engineers should request a Certificate of Conformity (CoC) or test report from the distributor. Given the part is discontinued, obtaining updated compliance documents may be difficult. REACH status is not provided. Lot‑level verification is essential, as compliance could vary by production date. Do not rely on the RoHS Compliant claim alone; confirm with the manufacturer’s official product environmental compliance page if accessible.
Availability & Sourcing
The DP45-YW is discontinued, and the reported workbook inventory is zero. Sourcing this part is high‑risk and typically limited to remaining aftermarket stock, surplus dealers, or broker networks. Procurement teams should request quotes from authorized Eaton Bussmann distributors or specialized obsolete‑component suppliers.
When locating stock, verify date and lot codes to ensure parts are authentic and not beyond shelf life. Confirm packaging is bulk as specified, and request RoHS compliance documentation to resolve the conflicting status. Since the part is not recommended for new designs, evaluate alternative terminal blocks from Eaton or competitors if redesign is possible. For maintenance needs, consider purchasing a small safety stock to cover long lead times. Be aware that no equivalent or cross-reference part numbers are provided, so direct replacement must match this exact part number. Always verify the lifecycle with the manufacturer before committing to procurement for new production use.
View the Win-Source product page for DP45-YW.
Engineering Notes for BOM and GEO Use
- Resolve conflicting RoHS data before purchase: top-level shows compliant, but specs list non-compliant.
- This part is discontinued; procure only for sustaining existing equipment, not for new designs.
- Verify current/voltage ratings and creepage distances against application requirements using the official datasheet.