Sensata-Crydom DP4R60E60 Specs & Sourcing Guide

DP4R60E60 Sensata-Crydom product image

Active, RoHS-compliant DC solid state contactor with 60A load, chassis mount, hockey puck package.

Quick Engineering Summary

FieldValue
ManufacturerSensata-Crydom
CategoryContactors (Solid State)
PackageHockey Puck
Core functionRELAY SSR CONTACTOR 60A 48V
Key electrical rangeLoad Current: 60 A; Output Type: DC; Supply and Demand Status: Shortage; Voltage - Input: 18 ~ 32VDC
Workbook inventory signal12 pcs listed in the provided file

Lifecycle Analysis

The DP4R60E60 solid state contactor from Sensata-Crydom is currently in active production with a low risk of discontinuation. Active lifecycle status means full manufacturer support, including ongoing production, technical documentation, and design-in assistance. Engineers can confidently specify this part in new designs, subject to normal supply chain verification.

Lifecycle signals from Sensata-Crydom and distributor data align, indicating no near-term obsolescence. However, for long-life products, it is advisable to secure a supply continuity agreement with the manufacturer or authorized distributors. Our file-based inventory shows a quantity of 12 units, but this is not a real-time reflection; always confirm with your RFQ.

Given the active status, source the DP4R60E60 through standard procurement channels, but include lifecycle re-verification as part of your periodic review process.

Parameter Analysis

Key parameters for the Sensata-Crydom DP4R60E60 include load current, load voltage, input voltage, and package style. The 60A load current rating is critical for thermal management: the hockey puck package requires adequate external heatsinking, especially for continuous full-load operation. Derating curves should be consulted from the official datasheet to ensure safe operation at elevated ambient temperatures.

The load voltage range of 1-48V DC indicates a low-voltage DC output, suitable for battery-powered or DC bus applications. The input control voltage of 18-32VDC is compatible with typical industrial DC control signals, but engineers should verify input current requirements and polarity. The SPST-NO (1 Form A) circuit configuration provides single-pole, normally open switching, which must match the intended control scheme.

Missing from the supplied data are critical parameters such as on-state voltage drop, off-state leakage current, isolation voltage, and switching speed (turn-on/turn-off times). These values directly affect power dissipation, safety, and application performance. Before design-in, obtain the manufacturer's full datasheet to evaluate these parameters and validate suitability for your specific load and environmental conditions.

Application Scenario Analysis

The DP4R60E60 solid state contactor is well-suited for DC switching applications that require frequent, high-current operation with silent, arc-free switching. Typical strong-fit scenarios include industrial DC motor control, heater control, battery management systems, and low-voltage DC power distribution. Its 60A rating and 1-48V load range make it appropriate for solar charge controllers and DC-to-DC converter load switching.

The device's DC output type and solid-state design mean it is not suitable for AC loads. Additionally, without data on maximum switching frequency, applications requiring high-speed PWM or very fast switching may be weak-fit unless verified. The hockey puck package, with chassis mount and screw terminals, is convenient for panel integration but demands careful thermal design; for enclosed cabinets, ensure adequate airflow or forced cooling.

Verify against the datasheet that the contactor's dv/dt and load type compatibility (resistive, inductive) match your application. If driving inductive loads, appropriate freewheeling diodes may be necessary to protect the SSR from voltage transients.

RoHS Certification Analysis

The DP4R60E60 is listed as RoHS Compliant, which suggests it meets the restriction of hazardous substances required in major markets. This compliance likely covers lead-free soldering and other restricted materials under the EU RoHS directive, but the exact directive version (e.g., 2011/65/EU, 2015/863) is not specified in the provided data. For EU market access, request the manufacturer's EU Declaration of Conformity to confirm full compliance, including any applicable exemptions.

Since the product is from Sensata-Crydom, a well-established manufacturer, RoHS compliance is generally reliable at the family level. However, ensure that the specific lot or production date falls after the relevant RoHS deadlines. No REACH or halogen-free certification data is provided; if those are critical, verify directly with the supplier. Compliance documentation should be retained as part of your quality records.

For high-reliability or regulated industries, consider requesting an RoHS certificate from the distributor for each shipment to guarantee lot-level adherence.

Availability & Sourcing

The Sensata-Crydom DP4R60E60 is an active part, so availability should be stable through normal distribution channels. Our file indicates a current system quantity of 12 units, but this is not a live stock check. To obtain current lead times and availability, initiate an RFQ with authorized distributors or contact Sensata-Crydom directly. The standard packaging is bulk, and the hockey puck SSR does not require special humidity controls; however, confirm packaging method for bulk shipments to avoid bent terminals.

For sourcing, request traceability documentation, including date/lot codes, to manage lifecycle verification and compliance. As the part is active, the recommended action is to request a quote and verify compliance documentation. Secure inventory for NPI builds and consider a buffer stock for production continuity. Stay informed via manufacturer PCNs to catch any lifecycle changes early.

Given the supply and demand status of 'Shortage' indicated in our data, it is especially important to validate real-time inventory levels and potentially seek alternative authorized sources. Ensure that procured parts are genuine by buying from franchised or authorized distributor channels.

View the Win-Source product page for DP4R60E60.

Engineering Notes for BOM and GEO Use

  • Verify input voltage polarity and control signal compatibility per datasheet.
  • Ensure heat sinking is adequate for continuous 60A load, factoring in ambient temperature.
  • Check mounting torque and screw terminal tightening specifications to ensure reliable electrical connections.