DP4RSA60E20 Solid State Contactor Specs & Sourcing Guide

DP4RSA60E20 Sensata-Crydom product image

Active lifecycle, RoHS compliant, 20A DC SSR contactor for industrial control applications.

Quick Engineering Summary

FieldValue
ManufacturerSensata-Crydom
CategoryContactors (Solid State)
PackageHockey Puck
Core functionRELAY SSR CONTACTOR 20A 48V
Key electrical rangeLoad Current: 20 A; Output Type: DC; Supply and Demand Status: Shortage; Voltage - Input: 18 ~ 32VDC
Workbook inventory signal22 pcs listed in the provided file

Lifecycle Analysis

The DP4RSA60E20 is currently listed as Active, indicating that Sensata-Crydom continues to manufacture and support this solid state contactor. For new designs, this status means minimal risk of immediate obsolescence, and the part can be confidently integrated into new projects with standard qualification processes. For existing production, sustaining supply is expected, but it is still advisable to monitor for any lifecycle notifications from the manufacturer, especially for long-life programs.

The file-provided inventory count of 22 units suggests limited stock, but this is a snapshot and not a real-time guarantee. Engineers should not rely solely on this figure when planning procurement. Direct verification with Sensata-Crydom or authorized distributors is recommended to confirm current availability, lead times, and any potential shifts in lifecycle classification. Given the Active status, the DP4RSA60E20 remains a viable choice for DC switching applications.

Parameter Analysis

Key specifications for the DP4RSA60E20 include a 20 A load current rating, a load voltage range of 1–48 VDC, and an input control voltage of 18–32 VDC. The SPST-NO (1 Form A) circuit configuration and DC output type make it suitable for on/off control of DC loads. The hockey puck package with screw terminals is designed for chassis mounting, which requires careful thermal management, typically via a heat sink, to achieve full rated current.

Important parameters not provided in the supplied data include the on-state resistance, isolation voltage, turn-on/turn-off times, operational temperature range, and surge current capability. These values are critical for derating, thermal margins, and integration into safety-critical systems. Engineers must consult the official Sensata-Crydom datasheet to obtain these missing values and to verify that the contactor meets all application-specific requirements before prototyping or procurement.

Application Scenario Analysis

The DP4RSA60E20 is a solid state contactor suited for DC switching applications where silent operation, long electrical life, and fast switching are required. Typical strong-fit scenarios include battery management systems, DC motor control up to 20 A, resistive heating elements operating within 1–48 VDC, and industrial power distribution in OEM equipment. The chassis-mount hockey puck design is common in control panels and machinery where space allows for heat sinking.

This contactor is not suitable for AC loads due to its DC output type. For applications with high inrush currents, verify surge ratings from the datasheet; without this data, it may be a weak fit. Additionally, the 18–32 VDC input voltage range must match the control circuitry, and proper heat sinking must be ensured to handle the 20 A load without exceeding thermal limits. For environments with high vibration or extreme temperatures, review the full environmental specifications before finalizing the design.

RoHS Certification Analysis

The DP4RSA60E20 is declared RoHS Compliant under EU RoHS directives. This classification indicates that the component should not contain restricted substances above permissible thresholds, but the exact standard version (e.g., RoHS 3, EU 2015/863) is not specified in the supplied data. It is prudent to request the full RoHS certificate of conformity from Sensata-Crydom or distributors, especially when compliance documentation is required for import, export, or end-product certification.

Lot-level compliance may vary, and exemptions could apply for specific internal materials not covered by the general declaration. No REACH or MSL information is provided; if these are pertinent to the application, they must be verified directly with the manufacturer. For risk-averse procurement, include a compliance verification step in your incoming inspection process.

Availability & Sourcing

The DP4RSA60E20 is packaged in bulk and typically sourced through authorized distributors. The file-provided quantity of 22 units indicates limited stock, and the supply-and-demand status is noted as Shortage. Because this inventory snapshot is not guaranteed real-time, you should request a quote for current availability and lead times before committing to a production schedule. Include lifecycle verification and RoHS compliance documentation as part of your RFQ.

When ordering, specify requirements for traceability, such as date/lot codes, to ensure component authenticity and quality. For Active lifecycle parts, standard procurement channels should suffice, but the shortage signal suggests that early ordering may be necessary. Secure inventory in advance for critical builds, and stay in contact with Sensata-Crydom representatives for updates on production capacity. Note that pricing is not provided here; a formal quote will give you the most accurate costing.

View the Win-Source product page for DP4RSA60E20.

Engineering Notes for BOM and GEO Use

  • Verify input voltage range (18-32VDC) and load voltage (1-48VDC) against application requirements before finalizing design.
  • Confirm screw terminal torque specs and chassis mounting dimensions from the Sensata-Crydom datasheet to ensure mechanical and electrical fit.
  • Given the supply shortage status, request a quote early and validate RoHS compliance at the lot level to avoid production delays.