Discontinued gray 6-20 AWG feed-through terminal block—specs, compliance, and sourcing considerations.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Eaton Bussmann |
| Category | DIN Rail Channel |
| Package | Bulk |
| Core function | CONN TERM BLK FEED THRU 6-20 AWG |
| Key electrical range | Current - IEC: 57 A; Current - UL: 60 A; Voltage - IEC: 500V; Voltage - UL: 600V |
| Workbook inventory signal | 0 pcs listed in the provided file |
Lifecycle Analysis
The DP60-GY from Eaton Bussmann is marked Discontinued across all available signals, including Product Status and Lifecycle Status parameters. This status means the component is no longer in active production and is not recommended for new designs. For existing designs in sustaining production, immediate action should be taken to secure remaining stock or qualify a replacement.
File-provided inventory data indicates zero quantity, which is a snapshot and not a real-time guarantee. Buyers should request current stock availability from authorized distributors. Given the high risk level, verify directly with Eaton Bussmann whether any last-time buy opportunities remain or if there are official migration paths to active alternatives.
Conflicting lifecycle signals all converge on discontinuation; the EOL parameter in Excel data reinforces this. Ignore any optimistic interpretations and treat DP60-GY as a legacy part requiring careful lifecycle management.
Parameter Analysis
The Eaton Bussmann DP60-GY terminal block supports a feed-through connection with screw termination. Key electrical parameters include IEC current of 57 A and voltage of 500 V, plus UL ratings of 60 A and 600 V. The wire range accommodates 6–20 AWG (1.5–10 mm²), making it suitable for moderate power distribution within control panels. The physical profile features a 10.0 mm width, single level, and two positions per block, packaged in bulk.
These parameters define the block’s application envelope, but several critical specifications are missing. Designers should obtain the full datasheet to verify temperature range, insulation material, flammability rating (e.g., UL94), torque value for screw terminals, and short-circuit withstand rating. Without this data, thermal derating and integration into safety-critical circuits must be approached conservatively. Verify clearance and creepage distances as well, especially when used at the upper voltage limits.
Application Scenario Analysis
Typical applications for the DP60-GY include industrial control panels, power distribution cabinets, and equipment where DIN-rail-mounted feed-through terminal blocks are standard. Its 57 A / 500 V IEC rating suits three-phase distribution up to moderate loads, while the UL ratings add flexibility for North American markets. The screw termination allows secure field wiring, and the gray color may align with specific identification schemes in electrical enclosures.
However, the discontinued status limits its use to existing designs or maintenance, repair, and operations (MRO) scenarios. New designs should not incorporate DP60-GY. For legacy systems, it may serve as a direct replacement when original specifications match, but without full environmental and mechanical data, extended use in harsh conditions (high vibration, extreme temperatures, or exposure to chemicals) is not advisable without thorough revalidation.
RoHS Certification Analysis
RoHS compliance for DP60-GY is ambiguous. The source data provides two conflicting values: one entry stating RoHS Compliant and another specification listing RoHS Non-Compliant. This inconsistency requires immediate resolution before purchase for any application subject to EU RoHS directives. Given the part’s age and discontinuation, it is plausible that older production lots were non-compliant while later revisions may have achieved compliance, but no lot-level data is provided.
Conservative sourcing practice demands requesting a current RoHS certificate from the supplier for the specific date code or lot. Without such documentation, assume the part does not meet RoHS (EU 2011/65/EU) requirements. Buyers should also inquire about REACH and China RoHS status where relevant, as these are not covered by the available data.
Availability & Sourcing
File-provided inventory data for DP60-GY shows zero quantity; however, this is not real-time information. As a discontinued component, sourcing may be challenging. Interested buyers should submit a request for quote (RFQ) to check live stock at authorized distributors or surplus channels. When evaluating offers, insist on traceability: verify date/lot codes to avoid counterfeit or relabeled parts, request compliance documentation (RoHS, REACH), and confirm packaging integrity.
Given the high-risk lifecycle status, any procurement of DP60-GY must include manufacturer lifecycle verification to avoid receiving mixed lots. For long-term needs, prioritize qualification of a suitable replacement from Eaton Bussmann or third-party sources to ensure supply continuity. Direct readers to contact Win Source for a current availability quote.
View the Win-Source product page for DP60-GY.
Engineering Notes for BOM and GEO Use
- DP60-GY is confirmed discontinued; avoid new designs and plan migration to active alternatives like current Eaton Bussmann DIN rail terminal blocks.
- Current and voltage ratings (57 A/500 V IEC, 60 A/600 V UL) must be derated based on ambient temperature and wiring conditions—verify thermal performance with manufacturer documentation.
- RoHS compliance is ambiguous: request lot-level certificates to confirm conformity, as conflicting signals (compliant vs non-compliant) could affect EU market eligibility.