DP606A Omega Engineering Panel Meter Specs & Sourcing Guide

DP606A Omega Engineering product image

Active lifecycle process/temperature meter with versatile sensor inputs, dual relay outputs, and 3.5-digit LED display. Verify RoHS compliance and stock before design-in.

Quick Engineering Summary

FieldValue
ManufacturerOmega Engineering
CategoryCustom Parts (B - D)
PackageNot available in supplied data
Core functionPROCESS/TEMP METER LED PANEL MNT
Key electrical rangeSupply and Demand Status: Limited
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The DP606A is listed as having an Active lifecycle status by Omega Engineering, indicating that the component is in full production and recommended for new designs as well as ongoing supply for existing production. No end-of-life (EOL) or discontinuation notices are associated with this part number based on the supplied data. However, engineers should note that lifecycle status can change, and for mission-critical designs it is advisable to revalidate directly with the manufacturer or an authorized distributor, especially if the part will be used in long-lifecycle products. The file-provided inventory indicates a single unit in stock, which may not reflect real-time availability. While the Active status suggests ongoing support, the limited stock signal should prompt sourcing teams to verify lead times and production schedules before committing to volume builds. There are no conflicts in lifecycle signals across the provided data sources, lending confidence to the Active classification. Nonetheless, conservative procurement practices recommend securing a second source or confirming supply continuity for production planning.

Parameter Analysis

The DP606A is a panel-mount process and temperature meter with a 3.5-digit red LED display and 15.00 mm character height, providing clear readability in typical industrial control environments. It accepts multiple input types including thermocouple, RTD, current (4-20 mA), and voltage (0-1 V), covering a wide temperature measurement range from -200°C to 1820°C, making it versatile for various sensor interfaces. The meter includes two relay outputs, enabling direct on/off control or alarm functions, and is powered from 120-240 VAC mains. Its square panel cutout dimensions are 92.00 mm x 92.00 mm, and it uses screw terminals for wiring. Key parameters to verify from the manufacturer’s datasheet include measurement accuracy, input impedance, sampling rate, relay contact ratings, isolation voltage, and any programmable features. Ingress protection is not specified, so suitability for dusty or wet environments must be assessed. The 3.5-digit display limits resolution; confirm if it meets system precision requirements. Also check environmental ratings, operating temperature range, and safety certifications. Packaging is bulk, which may affect handling in automated assembly.

Application Scenario Analysis

The DP606A is well-suited for industrial panel-mount applications that require local display and control of process variables like temperature. Typical strong-fit scenarios include simple temperature monitoring and alarm in HVAC systems, plastics extrusion, heat treatment ovens, and environmental chambers. Its ability to directly accept thermocouples and RTDs without external transmitters reduces system complexity and cost. The dual relay outputs allow for high/low limit alarms or basic on/off control, though more complex PID control would need a dedicated controller. Weak-fit applications include those demanding high-accuracy data logging (where higher resolution and digital interfaces are required), or environments with heavy vibration, corrosive atmospheres, or washdown due to the unspecified ingress protection. The 3.5-digit display limits precision to about 0.1% of full scale; sub-degree resolution applications may find it inadequate. Evaluate panel depth and wiring space for the 92x92 mm cutout, and consider noise immunity if installed near VFDs or high-power equipment.

RoHS Certification Analysis

RoHS compliance information for the DP606A is inconsistent within the supplied data. One data field reports 'RoHS Compliant,' while the part-specific specification record lists 'RoHS Status: RoHS Non-Compliant.' This discrepancy requires immediate clarification before procurement for EU or other RoHS-regulated markets. Typically, the part-level specification listing is considered more authoritative; however, it may represent an older or inaccurate entry. No additional compliance details such as specific RoHS version or exemption numbers are provided, nor is there any REACH or halogen-free information. Until resolved, the most conservative approach is to treat the DP606A as possibly non-compliant, particularly for new designs. Sourcing teams should request a current certificate of conformity from Omega Engineering or an authorized distributor that explicitly states RoHS compliance status and applicable exemptions. For production destined for the European Union, verifying lot-level compliance is essential, as older stock may not meet current RoHS directives. The storage condition indicates dry cabinet and humidity protection, but no MSL is specified; this is less critical for panel meters, but if reflow soldering is used, MSL should be confirmed.

Availability & Sourcing

Current file-provided inventory for the DP606A shows a single unit in stock, with supply and demand status categorized as limited. This does not guarantee real-time availability, but it signals that the part may be scarce or on allocation. The lifecycle is Active, which normally suggests ongoing production, but the limited inventory flag warrants proactive sourcing. Buyers should request a formal quote (RFQ) to confirm current stock levels, lead times, and minimum order quantities directly from Omega Engineering or their authorized distributors. Given the 34% reported fake threat in the open market, it is critical to source through authorized channels and request traceability documentation, including date/lot codes and certificates of conformance. The part is packaged in bulk, so tape-and-reel or tray options are unavailable; this may affect automated assembly. To secure supply for ongoing production, consider asking the manufacturer for last-time-buy commitments or alternates if the part approaches NRND in the future. Verify storage conditions upon receipt, and maintain dry storage with humidity protection. As a custom part, broaden the search to factory-direct or specialist industrial automation distributors if needed. Finally, double-check RoHS compliance documentation as part of the sourcing qualification to avoid non-compliant inventory purchases.

View the Win-Source product page for DP606A.

Engineering Notes for BOM and GEO Use

  • Verify RoHS compliance directly with Omega Engineering; conflicting status flags require resolution before use in regulated markets.
  • Confirm actual inventory and lead times with your supplier; listed stock is limited and not guaranteed real-time.
  • Assess input compatibility and panel cutout dimensions carefully to avoid integration delays.