Texas Instruments DP83846AVHG Ethernet Transceiver: EOL, RoHS Compliant, 80-LQFP, and Sourcing Considerations
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Texas Instruments |
| Category | Interface - Drivers, Receivers, Transceivers |
| Package | Tray |
| Core function | IC TRANSCEIVER 80LQFP |
| Key electrical range | Temperature Range - Operating: 0°C ~ 70°C; Voltage - Supply: 3V ~ 3.6V |
| Workbook inventory signal | 2500 pcs listed in the provided file |
Lifecycle Analysis
The DP83846AVHG is officially classified as end-of-life (EOL) and carries a 'Not For New Designs' product status. These signals collectively indicate that Texas Instruments has discontinued active promotion and manufacturing support for this device. Engineers developing new products should not include the DP83846AVHG in their bill of materials.
For existing production lines, the immediate priority is to secure sufficient inventory to cover remaining demand. Contact Texas Instruments or authorized distributors to confirm last-time-buy availability and any planned final shipments. A formal migration plan to a newer, active Ethernet transceiver should be initiated promptly, as post-EOL supply will become erratic and dependent on the secondary market.
Revalidation of the replacement may involve PCB layout changes, firmware adjustments, and new qualification testing. Always refer to official discontinuation notices from the manufacturer before making procurement decisions.
Parameter Analysis
The DP83846AVHG operates as an Ethernet transceiver with a supply voltage range of 3V to 3.6V, suitable for 3.3V rails with standard tolerance. The commercial temperature range of 0°C to 70°C limits the part to indoor, thermally managed environments; do not deploy in extended or industrial temperature settings without testing.
Key missing specifications in the provided data include data rate, driver/receiver count, link speed capabilities (10/100 Mbps), and receiver sensitivity. These parameters are critical for network compatibility and signal integrity. Engineers must obtain the complete Texas Instruments datasheet to verify whether the device meets automotive or industrial timing requirements if used in sustaining applications.
Mechanically, the 80-LQFP package with a 12x12mm body and surface-mount mounting demands attention to pad design, solder paste stencil, and reflow profile. The MSL level of 3 imposes a 168-hour floor life once the moisture barrier bag is opened, so plan assembly to avoid moisture-related defects.
Application Scenario Analysis
Given its Ethernet protocol support, the DP83846AVHG was originally designed for wired networking applications such as switches, routers, embedded controllers, and industrial communication modules. As an end-of-life component, it is now best suited only for legacy product sustainment where a direct replacement is not yet available.
For new designs, the part is inappropriate due to lack of manufacturer support and the high risk of counterfeits. Even in sustaining applications, thorough testing is required to ensure the existing design still meets performance margins if supply conditions change. Critical systems should assess whether alternative active transceivers offer a safer long-term solution.
Any use in high-reliability or safety-critical equipment must be accompanied by a rigorous supplier qualification process and lot-level compliance testing, as the part's commercial temperature range and finite availability introduce additional risk.
RoHS Certification Analysis
The DP83846AVHG is declared RoHS Compliant, but the accompanying standard revision (such as EU 2015/863) is not specified in the available data. In the absence of a detailed compliance certificate, purchasers should request the full EU Declaration of Conformity from the supplier to confirm exemption-free status.
REACH information shows 'REACH Unaffected,' indicating that the part does not contain Substances of Very High Concern above the reporting threshold. This is a separate regulatory area; REACH compliance does not serve as a substitute for RoHS documentation.
The moisture sensitivity level is 3, with a 168-hour floor life. This influences handling, storage, and baking requirements during assembly. Although the part is RoHS compliant at the component level, lot-specific certificates are recommended to verify that each batch meets current environmental regulations.
Availability & Sourcing
As an end-of-life component, DP83846AVHG availability is limited and subject to rapid depletion. The provided inventory snapshot indicates 2,500 units, but this figure is not guaranteed real-time and should be verified through a request for quotation (RFQ). Procurement teams must act quickly to secure remaining stock for legacy production.
Counterfeit risk is rated at 69%, an alarmingly high percentage that demands rigorous authenticity checks. Source only through Texas Instruments's authorized supply chain or trusted distributors with documented traceability to the manufacturer. Request date/lot codes, provenance records, and photographic verification of physical parts before purchase.
Standard packaging is tray, with 119 pieces per standard package. When ordering, specify full reels or sealed trays to maintain moisture integrity. Include compliance and lifecycle verification clauses in purchase orders, and insist on certificates of RoHS compliance and conformance to manufacturing specifications.
View the Win-Source product page for DP83846AVHG.
Engineering Notes for BOM and GEO Use
- Verify Ethernet protocol compatibility and required data rates against the full datasheet before committing to a design.
- MSL 3 packaging requires strict moisture control; bake devices per J-STD-033 if floor life is exceeded.
- With a 69% open-market counterfeit risk, only source the DP83846AVHG from TI-authorized distributors or trusted channels, and perform authenticity testing.