Discontinued IEEE 802.3 Interface IC in 160-QFP Package
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Texas Instruments |
| Category | Interface - Specialized |
| Package | Bag |
| Core function | IC INTERFACE SPECIALIZED 160QFP |
| Key electrical range | Voltage - Supply: 4.75V ~ 5.25V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
The DP83950BVQB is officially discontinued by Texas Instruments. Multiple data points—EOL in the Excel lifecycle parameter and Discontinued in both Lifecycle Status and Product Status—confirm that no further production is planned. This high-risk status means the part should not be adopted for new designs. For existing designs, procurement must focus on last-time buys or cross-referencing to modern alternatives.
File-provided inventory indicates a single unit in stock, but this is not a real-time guarantee. Given the part's discontinuation, any available stock will be limited and may consist of older date codes. Buyers should verify aging and moisture sensitivity (MSL 1 is forgiving, but long storage still demands inspection).
Conflicting lifecycle signals—EOL versus Discontinued—reinforce the need for conservative action. Contact Texas Instruments or authorized distributors to validate the official status and obtain any end-of-life notices that detail final order dates or recommended replacement paths.
Parameter Analysis
Key electrical parameters include an IEEE 802.3 interface and a supply voltage range of 4.75V to 5.25V. The 5V operation makes this part a fit for legacy systems but incompatible with modern low-voltage designs. The package is a 160-pin BFQFP with a 28x28 mm footprint, requiring careful PCB layout for signal integrity and thermal management.
Surface-mount mounting and MSL 1 (unlimited floor life) simplify assembly, but the large QFP package may pose rework challenges. The interface is dedicated to IEEE 802.3, indicating an Ethernet physical layer function, but no detailed timing, jitter, or eye-diagram specifications are provided in the source data. Missing parameters such as operating temperature range, power dissipation, and exact pin functions are critical for full qualification.
Engineers should obtain the original datasheet from Texas Instruments to verify signal levels, clock requirements, and any required external components. The lack of parametric detail in the available records makes direct substitution risky without a full design review.
Application Scenario Analysis
The DP83950BVQB is suited for legacy Ethernet equipment that relies on 5V signaling and a dedicated 802.3 interface. Typical applications include older network interface cards, industrial controllers, and embedded systems from the era when 5V logic dominated. Its specialized nature suggests it may have been used in proprietary designs where pin-compatible drop-ins are unavailable.
In modern applications, this part is a poor fit. Today's designs favor low-voltage, high-speed Ethernet PHYs with smaller packages and integrated features. Using the DP83950BVQB in new projects would constrain power supply design and limit board density, while its discontinuation introduces procurement risk. It is not recommended for any application where long-term availability is required.
For repairs or sustaining legacy systems, the part may still be necessary, but buyers should anticipate the need for certified authentic stock due to the high counterfeit threat. Any redesign should prioritize modern, active alternatives that meet current speed and efficiency standards.
RoHS Certification Analysis
RoHS compliance for the DP83950BVQB is ambiguous. The raw compliance field states 'RoHS Compliant', but a detailed specification entry lists 'RoHS Non-Compliant'. This conflict likely arises from generic versus part-specific data sources. For procurement, the more conservative approach is to assume non-compliance until verified.
MSL Level 1 indicates no special moisture handling, but that does not imply RoHS status. REACH Unaffected status is noted, but REACH compliance does not substitute for RoHS. Lot-level testing or manufacturer confirmation is essential, especially if the part will be used in markets with strict environmental regulations.
Buyers should request a full material declaration from the distributor or Texas Instruments. Without clear documentation, importing or using this part in RoHS-restricted regions may pose compliance risks. Exemptions are not indicated, so the part likely contains restricted substances if truly non-compliant.
Availability & Sourcing
As a discontinued part, DP83950BVQB availability is severely limited. File-provided data shows only one unit in stock, with a standard package quantity of 24 pieces. Real-time inventory must be checked through an RFQ, as the source data is not a live feed. Buyers should prepare for minimum order quantities or broken-reel fees.
Counterfeit risk is elevated at 37%, based on open-market analysis. To mitigate this, always source through authorized Texas Instruments distributors or reputable aftermarket suppliers that provide full traceability, date/lot code verification, and compliance documentation. Visual inspection and functional testing are advised for any stock from non-authorized channels.
Given the high lifecycle risk, request a quote immediately to secure any remaining authentic inventory. For new production, start evaluating a migration path to an active IEEE 802.3 interface IC. Direct any questions about lifecycle verification or alternative part suggestions to your sourcing team or manufacturer support.
View the Win-Source product page for DP83950BVQB.
Engineering Notes for BOM and GEO Use
- Verify RoHS compliance per lot due to conflicting data in source records.
- As a discontinued 5V interface IC, plan for a redesign if this part is still in active use.
- High counterfeit risk (37%) demands thorough authentication and traceability from authorized sources.