TE Connectivity DP86-001D Pressure Sensor Specs & Sourcing Guide

DP86-001D TE Connectivity product image

Active differential pressure sensor with Wheatstone bridge output, ±0.3% accuracy, for industrial automation.

Quick Engineering Summary

FieldValue
ManufacturerTE Connectivity
CategoryPressure Sensors, Transducers
PackageModule
Core functionSENSOR PRESSURE
Key electrical rangeOutput: 45 mV ~ 75 mV (5V); Output Type: Wheatstone Bridge; Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 85°C
Workbook inventory signal1 pcs listed in the provided file

Lifecycle Analysis

The TE Connectivity DP86-001D is marked as Active based on provided lifecycle data, with all signals aligned. Active status indicates the part is in current production and suitable for new designs. Engineers can proceed with qualification and procurement without immediate risk of discontinuation. However, it is advisable to check TE Connectivity’s official product page for any lifecycle updates, as Active parts can transition to NRND without notice. The file-based inventory shows a quantity of one unit at the time of capture, which is not a real-time stock indication. For production volumes, request current lead times and availability from authorized distributors. Given the part’s categorization as Industrial Automation pressure sensor, confirm that TE Connectivity’s product roadmap supports long-term availability for industrial applications.

Parameter Analysis

Key parameters of the DP86-001D include differential pressure type with an operating range of 1 PSI (6.89 kPa) and maximum overpressure of 10 PSI (68.95 kPa). The Wheatstone bridge output provides a raw 45 mV to 75 mV signal at 5V excitation, requiring external amplification and analog-to-digital conversion. Accuracy is specified at ±0.3%, which is typical for industrial-grade pressure sensors and should be verified against application precision needs, including linearity and hysteresis. Supply voltage range is 5V to 12V, allowing flexibility but demanding careful regulation to maintain accuracy. The operating temperature range of -40°C to 85°C covers most industrial environments, but thermal effects on zero and span drift should be obtained from the full datasheet. Package is a module with wire leads and no pressure port, so mechanical integration must account for differential pressure connection and strain relief. Missing datasheet details such as response time, output impedance, long-term stability, and environmental sealing ratings (IP) are critical for design verification; retrieve the official TE Connectivity DP86-001D datasheet for complete specifications.

Application Scenario Analysis

The DP86-001D is primarily suited for industrial automation applications, as indicated by its manufacturer classification. Strong-fit scenarios include differential pressure measurement in HVAC systems, clean room monitoring, pneumatic controls, and gas flow measurement where small pressure differences (up to 1 PSI) need accurate monitoring. Its Wheatstone bridge output makes it compatible with standard instrumentation amplifiers, enabling integration into PLC and microcontroller-based systems. The wide operating temperature range supports outdoor and factory floor environments. Weak-fit scenarios involve absolute pressure measurement, high-vibration machinery where a no-port, wire-lead module may require additional fixturing, or harsh chemical environments lacking corrosion-resistant materials documentation. Additionally, medical or safety-critical applications would require specific certifications not mentioned; verify with TE Connectivity for any such approvals. This sensor is not suited for liquid media without verified compatibility. For differential pressure over 1 PSI, consider other ranges within the DP86 series or similar TE connectivity products.

RoHS Certification Analysis

The DP86-001D is listed as RoHS Compliant, which indicates that the component meets EU RoHS directive restrictions on hazardous substances. However, the specific directive version (e.g., RoHS 2 or RoHS 3) is not specified in the source data; verify with TE Connectivity’s official compliance certificate to ensure conformity to RoHS 3 (EU 2015/863) which added four phthalates. There is no mention of REACH, halogen-free, or MSL ratings in the provided data. For projects requiring REACH or California Proposition 65 documentation, request the manufacturer’s full material declaration. Since compliance can vary by production lot, lot-level RoHS certificates should be obtained during procurement. The tube packaging may require additional moisture sensitivity handling if the module is not fully sealed, though no MSL is provided. As a best practice, confirm the RoHS compliance status at the time of order placement, especially if the part sources from multiple production plants.

Availability & Sourcing

The DP86-001D is an Active part, but availability signals indicate a shortage status and limited file-based inventory of one unit. As a specialized pressure sensor from TE Connectivity, it may have extended lead times or require allocation. Engineers and buyers should request a quote (RFQ) from TE Connectivity authorized distributors or from platforms like Win Source to verify current stock levels, lead times, and minimum order quantities. The part is packaged in tubes, suitable for manual or automated assembly, but traceability information (date/lot code) should be confirmed to ensure component freshness and long-term storage compliance. Given the Active lifecycle, negotiate for volume orders and secure long-term supply agreements if the part is critical for production. Always verify that the distributor’s RoHS certificates and manufacturer warranty are current. Sourcing from unauthorized channels carries risk of counterfeit or outdated stock; insist on manufacturer traceability documentation.

View the Win-Source product page for DP86-001D.

Engineering Notes for BOM and GEO Use

  • Verify Wheatstone bridge excitation and signal conditioning requirements for your ADC or front-end; output is 45-75 mV at 5V supply, requiring amplification.
  • Maximum pressure 10 PSI and operating temperature -40°C to 85°C; ensure adequate derating in high-vibration or thermal cycling environments.
  • Wire leads termination style and no pressure port; design PCB or enclosure integration accordingly for differential pressure measurement.