Differential pressure sensor with 0–100 mV output, 500 PSI range, and RoHS compliance.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | TE Connectivity |
| Category | Pressure Sensors, Transducers |
| Package | Module |
| Core function | SENSOR PRESSURE |
| Key electrical range | Output: 0 mV ~ 100 mV (5V); Output Type: Wheatstone Bridge; Supply and Demand Status: Shortage; Temperature Range - Operating: -40°C ~ 125°C |
| Workbook inventory signal | 2 pcs listed in the provided file |
Lifecycle Analysis
TE Connectivity’s DP86-500D is listed with a lifecycle status of Active. This indicates the part is currently in full production and officially supported for new designs as well as sustaining procurement in existing platforms. No conflicting lifecycle signals were identified among the available data sources.
For engineers integrating the DP86-500D into new products, the Active status removes the risk of premature obsolescence and generally ensures access to application support, datasheets, and product change notifications from the manufacturer. Procurement teams can proceed with qualification and volume planning under standard lead-time expectations. That said, the provided workbook inventory quantity of two units is a static file-based snapshot and not a real-time stock level; direct quotation is necessary to confirm current availability and lead times.
When planning long-life industrial programs, it is still prudent to periodically revalidate lifecycle status with TE Connectivity or authorized distribution, as product lines can shift without immediate notice. No near-term NRND or EOL triggers are apparent, so the DP86-500D remains a safe choice for pressure sensing designs with a typical industrial product lifecycle.
Parameter Analysis
Several parameters of the DP86-500D are critical to system integration. The 500 PSI differential operating pressure defines the sensor’s full-scale span, while the maximum pressure of 1500 PSI provides a 3× overpressure safety margin. Engineers should ensure their application’s normal and fault pressures fall cleanly within these limits to avoid mechanical damage. The accuracy specification of ±0.1% full scale is a key figure for measurement precision; however, the datasheet should be consulted for details on whether this is linearity, hysteresis, or a combined error band.
The output type is a Wheatstone bridge delivering 0 mV to 100 mV when excited with 5 V. This ratiometric analog signal requires external amplification and possibly offset correction, so the choice of instrumentation amplifier or ADC front end directly influences system-level accuracy. Supply voltage can range from 5 V to 9.5 V, offering flexibility, but sensitivity scales proportionally with excitation. The operating temperature range of -40°C to 125°C makes the DP86-500D suitable for harsh environments.
Notable missing data from the available specifications include thermal zero shift, long-term stability, response time, and compensated temperature range. These are essential for reliability predictions and should be verified from the official TE Connectivity datasheet before locking in the design.
Application Scenario Analysis
The DP86-500D differential pressure sensor targets industrial automation applications where differential pressure measurement is required. The sensor’s robust pressure rating and wide temperature range align well with HVAC airflow monitoring, filter clogging detection, and industrial gas or liquid flow measurement using differential-producing flow elements like orifice plates or venturi tubes.
Its no-port design and module package with wire leads suggest a board-mount or small-enclosure integration, where pressure connections are made via tubing to a manifold or custom housing. The 500 PSI full-scale range is relatively high for typical low-pressure HVAC differentials (which often measure in inches of water), so the DP86-500D is better suited for hydraulic or pneumatic systems operating at higher pressures, such as industrial machinery or process control skids.
Weak-fit scenarios include absolute or gauge pressure measurements, as the part is differential only. Battery-operated wireless sensors may also be a poor match because the Wheatstone bridge and required signal conditioning can impose higher continuous power draw. For low-pressure differential measurements (e.g., building pressurization), a sensor with a lower range would be more appropriate. Always cross-reference the application pressure range and environmental conditions against the TE Connectivity datasheet.
RoHS Certification Analysis
The provided compliance data indicates the DP86-500D is RoHS Compliant. This typically implies conformity to EU RoHS Directive 2011/65/EU as amended by 2015/863, restricting hazardous substances such as lead, mercury, and cadmium. No specific exemptions are listed in the available information.
RoHS compliance is generally declared at the product family or datasheet level. For high-reliability or regulated industries, it is advisable to request a certificate of compliance for the specific manufacturing lot or date code at the time of purchase. Additionally, while RoHS status is confirmed, other environmental regulations such as REACH are not addressed in the provided data. If REACH compliance is required, request a declaration from TE Connectivity or the distributor.
Because the DP86-500D is an active production part, current manufacturing should adhere to the latest RoHS requirements. However, older stock from non‑authorized channels could predate full compliance, emphasizing the need for traceable sourcing.
Availability & Sourcing
The DP86-500D is an Active product from TE Connectivity. A workbook entry indicates a quantity of two units; however, this is a static snapshot and not a binding inventory figure. Buyers should request a quote for real-time stock and lead times through authorized distribution or directly from the manufacturer.
When sourcing, specify the desired packaging (Tube), target quantities, and any traceability requirements such as date code or lot code. For critical applications, ask for full RoHS compliance documents and, if necessary, REACH declarations. Because the part is in Active production, standard lead times typically apply, but recent component market conditions can affect availability; direct inquiry is the best way to confirm.
For new designs, ordering evaluation samples before committing to volume is recommended to validate performance and mechanical fit. Given the DP86-500D’s active lifecycle, there is no urgency to perform a lifetime buy; however, reviewing TE Connectivity’s product change notices and any future end-of-life plans is a standard procurement practice. Contact your authorized TE Connectivity channel with the part number DP86-500D to initiate a quote.
View the Win-Source product page for DP86-500D.
Engineering Notes for BOM and GEO Use
- Verify the no-port mechanical interface and wire lead terminations fit your design before finalizing DP86-500D procurement.
- Plan for external amplification and ratiometric ADC to achieve system accuracy within the sensor’s ±0.1% specification.
- Confirm maximum overpressure rating of 1500 PSI and temperature range align with fault conditions in your application.