Active part with low risk, SPST-NO 1A 20-140V AC zero-cross, through-hole 16-DIP package, RoHS compliant
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Solid State Relays |
| Package | Tube |
| Core function | SSR RELAY SPST-NO 1A 20-140V |
| Key electrical range | Load Current: 1 A; Output Type: AC, Zero Cross; Voltage - Load: 20 V ~ 140 V |
| Workbook inventory signal | 17 pcs listed in the provided file |
Lifecycle Analysis
The DPA4111 from Sensata-Crydom is currently in an Active lifecycle status, with a low risk level according to manufacturer signals. This indicates the part is fully supported for new designs and continues in volume production. Engineers can confidently design-in the DPA4111 for new projects, though it remains good practice to regularly check with authorized distributors for any upcoming changes.
Sustaining production lines using this relay face minimal obsolescence risk. The alignment of product status, lifecycle status, and distributor stock signals confirms no immediate discontinuation threats. The file-provided inventory quantity of 17 units suggests current availability but should be re-validated through a live RFQ, as lead times and stock levels can shift.
Parameter Analysis
Key parameters defining the DPA4111 include its SPST-NO (1 Form A) circuit configuration, a 1 A load current rating, and an AC load voltage range of 20 to 140 V RMS. The zero-cross output type ensures switching occurs near the AC zero-voltage point, reducing inrush currents and electromagnetic interference. The 16-DIP through-hole package with PC pins suits wave-soldering assembly and simplifies prototyping.
Important specifications missing from the provided data include input LED forward current, isolation voltage, and thermal resistance. For robust design, obtain these from the manufacturer’s datasheet to calculate input drive margins and thermal derating. The 1 A load current is typically specified at a nominal ambient temperature; derating at elevated temperatures may be necessary, especially in enclosed enclosures. The 20 V minimum load voltage ensures reliable turn-off for low-voltage AC loads, while the 140 V maximum covers common industrial and consumer AC mains.
Application Scenario Analysis
The DPA4111 is well-suited for low-current AC switching tasks in industrial controls, HVAC equipment, home automation, and office machines. Its zero-cross feature minimizes EMI, making it a good match for resistive loads like heaters, lamps, and solenoids where noise-sensitive electronics are nearby. The through-hole package is ideal for designs already using wave soldering or manual assembly.
It is a weak fit for DC load switching or high-frequency PWM control. Inductive AC loads (motors, transformers) may require external snubbing if inrush or turn-off transients exceed the SSR’s ratings. Applications needing high-speed repetitive switching should consider the mechanical relay lifetime, as the solid-state design offers unlimited cycles within ratings but may not match the speed of purpose-designed MOSFET switches.
RoHS Certification Analysis
The DPA4111 is marked as RoHS Compliant, indicating compliance with EU Restriction of Hazardous Substances directives. While the exact directive version (e.g., RoHS 3 (EU 2015/863)) is not specified, the status is generally consistent with lead-free construction and absence of restricted substances above threshold levels.
For full compliance assurance, request a copy of the manufacturer’s RoHS certificate or relevant test reports, especially if your product requires documentation for CE marking or other regulatory filings. Exemptions are not listed; if your application uses an exempted substance, verify conformance directly with Sensata-Crydom. The MSL rating of "Not Applicable" is typical for through-hole packages and simplifies storage and baking procedures.
Availability & Sourcing
As an Active part, the DPA4111 can be sourced through standard distributor channels. The file indicates a workbook quantity of 17 units, but this figure is not a real-time inventory promise. Engineers and buyers should submit an RFQ to obtain current stock levels, lead times, and pricing—though no price data is provided here. The standard packaging is a tube of 50 pieces, suitable for small to medium production runs.
When sourcing, request traceability documentation including date/lot codes and original manufacturer certification to guard against counterfeit risks. The data flags a 37% fake threat in the open market, underscoring the importance of procuring from authorized sources. For production, verify lifecycle status with Sensata-Crydom at the time of order, and ensure RoHS compliance documents accompany each shipment. For NRND or EOL scenarios—though not currently applicable—but should the status change, secure last-time-buy inventory early.
View the Win-Source product page for DPA4111.
Engineering Notes for BOM and GEO Use
- Verify load current derating curves for your operating temperature range; the 1 A rating may degrade above 40°C ambient without heatsinking.
- Ensure PCB layout accommodates the 16-DIP (0.300" wide) through-hole pattern with proper creepage and clearance for 140 V load traces.
- Confirm zero-cross turn-on characteristic matches your application’s inrush current and EMI requirements; non-zero-cross variants may be needed for inductive loads.