SPST-NO 1 A 20-140 VAC SSR – Active Lifecycle
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Sensata-Crydom |
| Category | Solid State Relays |
| Package | Tube |
| Core function | SSR RELAY SPST-NO 1A 20-140V |
| Key electrical range | Load Current: 1 A; Output Type: AC, Zero Cross; Voltage - Input: 3.5 ~ 10VDC; Voltage - Load: 20 V ~ 140 V |
| Workbook inventory signal | 1780 pcs listed in the provided file |
Lifecycle Analysis
The DPA4119 from Sensata-Crydom carries an Active lifecycle status, indicating that the manufacturer continues to produce and support the part. For new designs, this means the relay can be confidently specified without risk of immediate obsolescence. All available lifecycle signals—Excel lifecycle parameter, Lifecycle Status, and Product Status—align as Active, removing any ambiguity for the procurement team.
The supplied file-based inventory of 1780 units suggests current availability, but this figure is not a live stock check and may change without notice. Engineers and buyers should reconfirm lead times and stock levels directly with authorized distributors before committing to production schedules. For high-reliability or long-life programs, it is advisable to periodically monitor the manufacturer's product change notifications (PCNs) to catch any future transitions to NRND or EOL.
Parameter Analysis
The DPA4119's critical parameters center on its load and control specifications. Rated for 1 A AC load current over a 20-140 VAC range, the relay is optimized for low-power switching applications. The zero-cross output type minimizes electrical noise and surge currents during turn-on, which is advantageous for resistive and some capacitive loads but may cause issues with highly inductive loads unless properly snubbed. The input control voltage of 3.5–10 VDC makes it compatible with standard logic-level and microcontroller outputs.
Mechanical attributes are equally important for integration. The through-hole 16-DIP package with PC pin terminations suits traditional wave-soldering assembly. The operating temperature range of -30°C to 80°C should be derated at the upper end if placed in an enclosed, unventilated enclosure. Missing from the provided data are isolation voltage and surge current ratings; these must be obtained from the full datasheet to ensure safety and compliance with end-product standards.
Application Scenario Analysis
The DPA4119 fits well in applications requiring silent, bounce-free switching of low-current AC loads. Typical strong-fit scenarios include control of small AC solenoids, indicator lamps, heater elements under 1 A, and I/O module replacements in PLC systems. The zero-cross feature is beneficial where EMI reduction is critical, such as in medical or audio equipment. Its DC logic-level input also simplifies interface with digital controllers.
Weak-fit scenarios arise when load currents exceed 1 A or when the load is purely inductive without proper transient protection, as the zero-cross may not be ideal. For DC load switching, an AC-output SSR like the DPA4119 is unsuitable. Users should also consider that the through-hole package and tube packaging imply a manual or semi-automated assembly process, which may not be optimal for high-volume SMT lines.
RoHS Certification Analysis
The DPA4119 is listed as RoHS Compliant, meeting EU directive requirements for hazardous substance restrictions. As a through-hole component, it is exempt from MSL moisture sensitivity classification, simplifying storage and handling. However, certification is typically at the component family level; for mission-critical projects, request a lot-specific certificate of compliance to guard against batch variations.
No explicit REACH declaration is provided in the source data, but REACH is a separate regulation and not a substitute for RoHS. Buyers should verify REACH compliance separately if needed for EU market access. Given the active lifecycle, Sensata-Crydom likely maintains up-to-date compliance documentation, which should be requested as part of the RFQ process.
Availability & Sourcing
With an Active lifecycle status, the DPA4119 is generally available through Sensata-Crydom's distribution channel. The source data indicates file-level inventory of 1780 units, but actual stock must be confirmed via quote. The component is supplied in tubes with a standard package of 50 pieces, which aids in handling for small-to-medium production runs.
The open market for this part carries a 55% fake threat rate, so sourcing from unauthorized brokers is strongly discouraged. To mitigate risk, restrict purchases to franchised distributors and request traceability documentation, including date/lot codes and RoHS certificates. For sustaining production, it is prudent to secure inventory and consider a second source strategy if the application allows. To obtain current availability and pricing, request a quote directly through the supplier portal.
View the Win-Source product page for DPA4119.
Engineering Notes for BOM and GEO Use
- Verify load voltage range and derating for ambient temperatures above 40°C before integrating into production.
- Zero-cross output reduces inrush but may not suit all inductive loads; confirm compatibility with load characteristics.
- Open-market counterfeit risk is 55% – procure only from Sensata-Crydom authorized distributors and request lot traceability.