24VA Laminated Core Transformer with Dual Primaries and Secondaries
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 24VA TH |
| Key electrical range | Current - Output (Max): Parallel 2.4A, Series 1.2A; Power - Max: 24VA; Voltage - Isolation: 1500Vrms; Voltage - Primary: 115V, 230V |
| Workbook inventory signal | 1 pcs listed in the provided file |
Lifecycle Analysis
Pulse DPC-20-1200B16 is in active production, with both product and lifecycle status listed as Active. This indicates full manufacturer support and no immediate end-of-life risk, making it suitable for both new designs and ongoing sustaining production. The part falls under a low risk category for procurement, with no conflicting lifecycle signals observed.
Even for active parts, buyers should periodically reconfirm lifecycle status directly via Pulse or authorized distributors. For high-volume or long-life projects, securing a manufacturer PCN (Product Change Notification) agreement can help manage future transitions. The supplied inventory shows a single unit, but this is file-based and not a real-time guarantee; actual availability must be verified through an RFQ.
Parameter Analysis
The DPC-20-1200B16 is rated for a maximum power of 24 VA, featuring a laminated core and dual primary windings that accept 115 V or 230 V input. The dual secondary can be configured in parallel for 10 V at 2.4 A or series for 20 V at 1.2 A, offering flexibility for different output requirements. Isolation is specified at 1500 Vrms, providing basic safety insulation for line-connected applications.
Dimensions are 41.28 mm L x 57.15 mm W with a seated height of 34.93 mm, which is important for PCB layout and enclosure fit. The through-hole PC pin termination and bulk packaging are standard for manual or automated assembly. Key missing parameters that engineers should verify from the datasheet include efficiency, load regulation, temperature rise, and insulation class. These factors directly affect thermal management and long-term reliability in the end application.
Application Scenario Analysis
This transformer is well-suited for low-power AC-DC power supplies, battery chargers, or auxiliary power in industrial controls where dual primary voltage capability supports worldwide mains operation. The laminated core construction provides robust, cost-effective performance at line frequencies, making it a natural fit for linear power supply designs and isolation stages in measurement equipment.
It is less optimal for high-frequency switch-mode power supplies due to core material and eddy-current losses. For audio applications requiring low magnetostriction noise, verify no-load hum characteristics. Without additional certifications (e.g., medical isolation), it should not be assumed safe for patient-connected medical devices without independent safety evaluation. The part’s relatively high weight (0.75 lb) may be a consideration in portable designs.
RoHS Certification Analysis
The DPC-20-1200B16 is marked RoHS Compliant, indicating that it meets the requirements of EU Directive 2011/65/EU, including the restriction of hazardous substances such as lead, mercury, and cadmium. This status supports use in RoHS-mandated markets and simplifies compliance documentation for CE marking.
However, RoHS compliance is often declared at the product family level; for critical applications, request a full material declaration or certificate of compliance specific to the production lot. No REACH or MSL information is provided in the current data, so those must be separately verified if required. For lead-free soldering, confirm terminal plating compatibility with your process, as through-hole parts are typically tin-lead or pure tin.
Availability & Sourcing
As an active Pulse Electronics power transformer, DPC-20-1200B16 is generally available through authorized distributors. The file data indicates a stock quantity of 1 unit, but this is not a real-time inventory check; buyers should issue an RFQ to confirm current availability, lead time, and pricing. The part is supplied in bulk packaging, typical for through-hole components.
When sourcing, request date/lot codes to verify freshness and traceability, and ask for the latest product change notifications to ensure the part remains in active production. For design qualification, sample units should be fully tested against the Pulse datasheet. Since the lifecycle is low risk, standard procurement practices apply, but always reconfirm lifecycle status with the manufacturer or authorized partners before committing to high-volume production.
View the Win-Source product page for DPC-20-1200B16.
Engineering Notes for BOM and GEO Use
- Verify efficiency, regulation, and temperature rise from the official Pulse datasheet to ensure the transformer meets your design’s thermal and load requirements.
- Note the dual secondary configuration: parallel for 10 V at 2.4 A, series for 20 V at 1.2 A; confirm wiring in your schematic to avoid incorrect voltage application.
- Request a RoHS certificate and full material declaration for your specific lot to support end-product environmental compliance.