DPC-24-35B57 Pulse Power Transformer Specs & Sourcing Guide

DPC-24-35B57 Pulse product image

Technical specifications and procurement guidance for Pulse DPC-24-35B57 1VA laminated core transformer.

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 1VA TH
Key electrical rangeCurrent - Output (Max): Parallel 70mA, Series 35mA; Power - Max: 1VA; Voltage - Isolation: 1500Vrms; Voltage - Primary: 115V, 230V
Workbook inventory signal0 pcs listed in the provided file

Lifecycle Analysis

The DPC-24-35B57 from Pulse is currently classified as Active with a low lifecycle risk. All available signals, including the product status and lifecycle status, consistently indicate active production. This means the part is fully supported for new designs and ongoing manufacturing. For new project insertion, engineers can proceed with confidence, but should be aware that lifecycle status can change without immediate notice.

Given the consistent Active status, the DPC-24-35B57 is appropriate for both prototyping and volume production. However, the source data includes a file-based inventory quantity of zero, which is not a real-time reflection of market availability. Designers should confirm current stock and lead times with Pulse or authorized distributors before finalizing BOM selections.

For procurement planning, while the risk is low, it is prudent to request a current lifecycle confirmation letter from the manufacturer for long-term programs. Additionally, monitor for any product change notifications (PCNs) that might affect form, fit, or function.

Parameter Analysis

The DPC-24-35B57 is a 1VA laminated core power transformer with dual primary windings supporting 115V and 230V inputs, and dual secondary windings configurable for parallel 12V or series 24V outputs. The maximum output current is 70mA in parallel and 35mA in series, making it suitable for low-power isolated applications. Isolation voltage is rated at 1500Vrms, providing safety margin for typical line-operated circuits.

Physical dimensions are 25.40mm length by 34.93mm width, with a seated height of 21.08mm. The through-hole PC pin termination and bulk packaging suggest it is intended for board-level assembly in low-volume or prototype builds. Weight is approximately 71.2 grams. No center tap is available, which simplifies wiring but limits rectifier configuration options.

Key parameters not explicitly listed include primary and secondary DC resistance, magnetic inductance, turns ratio, and temperature rise. These values are critical for efficiency, regulation, and thermal management. Engineers should obtain the full Pulse datasheet to verify these missing specifications and ensure the transformer meets application derating requirements, especially under sustained maximum load. Also, insulation class and creepage/clearance distances are not provided and must be checked for safety compliance.

Application Scenario Analysis

The DPC-24-35B57 is well suited for low-power industrial, consumer, and instrumentation applications requiring galvanic isolation from AC mains. Typical uses include powering small control circuits, sensors, relay drivers, or low-current analog front-ends. The dual primary configuration allows worldwide AC voltage compatibility, while the series/parallel secondary options provide flexibility for different voltage and current needs.

Strong-fit scenarios are those where space is not highly constrained and through-hole mounting is acceptable, such as in bench equipment, HVAC controllers, or non-portable appliances. The 1VA rating may be limited for designs requiring high inrush current capability or continuous full-power delivery in high ambient temperatures, so thermal environment must be considered.

Weak-fit scenarios include high-frequency switching power supplies, where a laminated core transformer would be too lossy and bulky compared to ferrite cores. Also, applications with stringent size or height restrictions might find the 21mm seated height problematic. Additionally, if the load current exceeds the specified 70mA or if tighter regulation is needed, a different part with higher VA rating or regulation specification should be evaluated.

RoHS Certification Analysis

The DPC-24-35B57 is listed as RoHS Compliant based on the provided data. This typically signifies that the part meets the requirements of the EU Restriction of Hazardous Substances directive, although the specific standard version (e.g., RoHS 2 or RoHS 3) is not stated. No exemptions are mentioned, and the absence of additional compliance flags like REACH or MSL data means those aspects must be verified separately.

For complete environmental compliance documentation, it is recommended to request the manufacturer's RoHS certificate and any available declarations for REACH, halogen-free, or other regional requirements. Lot-level certifications may be needed for high-reliability or regulated industries, as compliance status can vary between production batches.

Since the part is a through-hole transformer with likely lead-based finishes, the RoHS compliance may involve exemptions such as lead in solders for the internal connections. Engineers should confirm that the RoHS compliance aligns with their specific regulatory obligations before finalizing the design.

Availability & Sourcing

The DPC-24-35B57 is currently an Active part, but the provided inventory file shows a stock quantity of zero at this distribution node. This indicates that real-time availability must be confirmed by requesting a quote. As an Active component, standard lead times from Pulse or franchised distributors should be obtainable, but current market conditions may affect delivery.

To source this transformer, procurement teams should engage with authorized Pulse distributors and request a quotation that includes date code and lot code traceability. Verification of lifecycle status and RoHS compliance documentation should be part of the RFQ process. Bulk packaging is typical, so reel or tube options are not available; ensure handling and storage meet requirements.

For production planning, given the low lifecycle risk, securing inventory for upcoming builds is advisable but not urgent. However, since the file shows zero quantity, expedite the RFQ to determine if the part is readily available or subject to allocation. Always request a compliance certificate with each shipment to maintain traceability for quality audits.

View the Win-Source product page for DPC-24-35B57.

Engineering Notes for BOM and GEO Use

  • Consult the manufacturer datasheet for inductance, DC resistance, and thermal rise data before finalizing the power supply design.
  • Verify current lifecycle status and obtain a RoHS compliance certificate from Pulse for each production lot to ensure regulatory conformance.
  • Design PCB footprint to accommodate the through-hole package and consider sufficient clearance for 1500Vrms isolation requirements.