Active, 1VA laminated power transformer, 115/230V primary, 17/34V secondary, through-hole, RoHS compliant.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Pulse |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 1VA TH |
| Key electrical range | Current - Output (Max): Parallel 50mA, Series 25mA; Power - Max: 1VA; Voltage - Isolation: 1500Vrms; Voltage - Primary: 115V, 230V |
| Workbook inventory signal | 0 pcs listed in the provided file |
Lifecycle Analysis
The DPC-34-25B59 from Pulse is in active lifecycle status based on manufacturer signals, indicating full production support for new designs and ongoing procurement. The lifecycle status is aligned across multiple indicators, including product status and lifecycle status fields, with no conflicting data. This active status suggests that Pulse continues to manufacture this laminated core power transformer, making it suitable for both new product development and sustaining production requirements.
However, lifecycle designations can change, so buyers should periodically revalidate with Pulse or authorized distributors, especially for long-lifecycle programs. The file-provided inventory count shows zero units, but this is a snapshot and not a guarantee of real-time availability. For production quantities, direct engagement with supply chain partners is recommended to confirm lead times and allocation.
Parameter Analysis
The DPC-34-25B59 is rated for 1VA maximum power, a critical parameter that defines its usable load capacity. The dual primary windings accept 115V or 230V, enabling global voltage compatibility. Secondary windings can be configured in parallel for 17V at 50mA or in series for 34V at 25mA. These current ratings must be derated for thermal or ambient conditions not specified in the datasheet. The 1500Vrms isolation voltage is essential for safety in mains-connected circuits and should be compared against system-level isolation requirements.
Through-hole PC pin mounting and the laminated core construction are typical for low-frequency linear power supplies. The package dimensions (25.40mm L x 34.93mm W) and seated height (21.08mm) allow initial PCB layout planning, but full mechanical details such as pin spacing and footprint must be confirmed from Pulse's official drawing. Parameters like regulation, efficiency, and temperature rise are not provided here; engineers should obtain the complete Pulse datasheet to verify these for thermal and performance margins.
Application Scenario Analysis
This 1VA laminated core transformer is well-suited for low-power linear AC-DC power supplies, such as those found in appliance controls, sensor circuits, or small battery chargers. Its dual primary and secondary windings provide design flexibility for global usage and voltage configurations. The through-hole mounting makes it compatible with conventional wave-soldered PCB assemblies.
For applications requiring high efficiency, low standby power, or compact form factors, a switch-mode design might be more appropriate. The DPC-34-25B59 is not intended for high-frequency operation, and its 1VA rating limits it to very light loads. It is a poor fit for density-sensitive designs or systems needing secondary regulation beyond unregulated rectified DC. Evaluators should check Pulse's datasheet for load regulation and temperature rise to confirm suitability.
RoHS Certification Analysis
The DPC-34-25B59 is designated as RoHS Compliant, indicating conformity to the EU's Restriction of Hazardous Substances directive. While the exact directive version (e.g., EU 2015/863) is not explicitly listed, Pulse typically aligns with current RoHS requirements for active products. Buyers should request a certificate of conformance from the distributor for the specific production lot to ensure documentation matches shipment contents.
For applications requiring REACH compliance, halogen-free status, or specific MSL ratings, those are not specified in the provided attributes and must be verified separately. REACH compliance is not a substitute for RoHS, and both may be needed depending on market requirements. For high-reliability sectors, obtaining full material declarations from Pulse is advised.
Availability & Sourcing
Current workbook data shows zero inventory for DPC-34-25B59, but this file-based snapshot does not guarantee real-time availability. As the part is active, authorized distributors can typically source factory-fresh units. Procurement teams should request a quote through the platform to confirm lead times, minimum order quantities, and packaging options (bulk). For active components, standard sourcing workflow includes verifying manufacturer PCB date codes and lot traceability.
Since the lifecycle status is active, there is no immediate end-of-life risk, but for program longevity, it is prudent to check Pulse's roadmap. Buyers should also request RoHS compliance documentation with each shipment and consider stocking strategies if the component is sole-sourced. Direct engagement with Pulse or franchised distributors is recommended for accurate pricing and allocation.
View the Win-Source product page for DPC-34-25B59.
Engineering Notes for BOM and GEO Use
- Verify maximum secondary current ratings (50mA parallel, 25mA series) for load conditions and thermal derating.
- Confirm 1500Vrms isolation voltage meets system safety requirements and check regulation/efficiency from official Pulse datasheet.
- Request a quote to confirm real-time availability, as file-provided inventory shows zero stock for DPC-34-25B59.