Pulse DPC-40-110B26 Power Transformer Specs & Sourcing Guide

DPC-40-110B26 Pulse product image

Active 4.4VA laminated core transformer with dual primaries and secondaries, PCB mount. Verify compliance and request quote.

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 4.
Key electrical rangeCurrent - Output (Max): Parallel 220mA, Series 110mA; Power - Max: 4.4VA; Voltage - Isolation: 1500Vrms; Voltage - Primary: 115V, 230V
Workbook inventory signal0 pcs listed in the provided file

Lifecycle Analysis

The Pulse DPC-40-110B26 is in Active lifecycle status, indicating that the manufacturer currently supports full production. This status means the part is suitable for new designs and sustaining production, with no planned discontinuation. Procurement teams can integrate the DPC-40-110B26 into long-life products with low risk of obsolescence.

However, even for Active components, it is prudent to periodically revalidate lifecycle status directly with Pulse, especially for high-volume commitments. The file-provided inventory shows zero quantity, which should not be interpreted as actual market availability; always confirm with distributors. Because all lifecycle signals align, there is no conflict, and the risk level is low.

Parameter Analysis

Key parameters for the DPC-40-110B26 include its 4.4VA power rating, which defines the maximum apparent power it can deliver without excessive temperature rise. Engineers must ensure that the total load, considering power factor if non-resistive, stays within this limit. The dual primary windings (115V/230V) allow worldwide line voltage compatibility, while the dual secondaries can be configured in parallel for 20V at 220mA or in series for 40V at 110mA, offering flexibility for different circuit requirements.

The 1500Vrms isolation voltage is critical for safety and regulatory compliance, providing galvanic separation between primary and secondary. Physical dimensions (41.28mm x 31.75mm) and through-hole PC pin termination dictate PCB layout and mounting; the 34.93mm maximum height may constrain enclosure design. Missing from the available data are specifications such as operating temperature range, frequency response, regulation from no-load to full load, and insulation class, which must be verified from the manufacturer’s datasheet before finalizing the design.

Application Scenario Analysis

The DPC-40-110B26 is well-suited for low-power line-frequency applications that require safe isolation and step-down voltage conversion. Typical strong-fit scenarios include powering analog sensor circuits, relay drivers, small microcontrollers, or isolated gate drive supplies in industrial control panels. The laminated core construction is optimized for 50/60Hz operation, making it appropriate for mains-connected devices like small appliances, timers, and consumer electronics.

Weak-fit scenarios involve high-frequency switching power supplies or applications demanding tight regulation, as laminated transformers exhibit higher losses at elevated frequencies and inherent voltage drop under load. The part is not intended for DC-DC converter topologies or portable battery-powered equipment where size and weight are critical. Engineers should evaluate the temperature rise under full load in the intended enclosure to ensure reliability.

RoHS Certification Analysis

The Pulse DPC-40-110B26 is listed as RoHS Compliant, which indicates that it meets EU RoHS directives, likely RoHS 3 (2015/863). This compliance covers restrictions on lead, mercury, cadmium, hexavalent chromium, PBBs, PBDEs, and four phthalates. No specific exemptions are noted in the supplied data; if the transformer uses lead in some internal solders that are exempt under 7(c)-I or similar, it would still be considered compliant but should be confirmed.

For procurement, lot-level RoHS compliance documentation should be requested at the time of order to ensure batch-specific conformity. Additionally, while not specified, REACH compliance may also be relevant and can be verified with the manufacturer. The RoHS status likely applies to the entire DPC series, but verification of the exact construction materials is advised for applications with strict environmental requirements.

Availability & Sourcing

The DPC-40-110B26 is an Active component, and sourcing should begin with a request for quote (RFQ) to authorized Pulse distributors or via platforms like Win-Source. The file-provided inventory quantity is zero, but this does not reflect real-time stock; actual availability can vary. Since the part is Active, lead times are typically stable, but it is wise to confirm current factory lead time when placing orders.

The transformer is packaged in bulk, which is standard for through-hole components, and traceability should be ensured by requesting date/lot code information. For compliance, a Certificate of Conformance (CoC) verifying RoHS status should be obtained with each shipment. To mitigate any supply chain risks, consider alternate sources while verifying lifecycle status regularly. For new designs, request a quote to secure pricing and delivery timelines.

View the Win-Source product page for DPC-40-110B26.

Engineering Notes for BOM and GEO Use

  • Verify transformer regulation and no-load voltage from the official Pulse datasheet before final circuit design.
  • Confirm primary and secondary wiring diagrams for series/parallel operation to avoid misconnection.
  • Request lot-specific RoHS certificate when ordering to ensure compliance with current EU directives.