DPF18-250FIM-2K Quick Disconnect Terminal | Specs & Sourcing Guide

DPF18-250FIM-2K Panduit Corp product image

Panduit Corp fully insulated red male quick disconnect, 18-22 AWG, tape & reel, 0.250" tab width

Quick Engineering Summary

FieldValue
ManufacturerPanduit Corp
CategoryTerminals - Quick Connects, Quick Disconnect Connectors
PackageTape & Reel
Core functionCONN QC TAB 18-22AWG 0.
Key electrical rangeSupply and Demand Status: Normal
Workbook inventory signal6688 pcs listed in the provided file

Lifecycle Analysis

The DPF18-250FIM-2K is currently classified as Active by Panduit Corp, with all available lifecycle signals aligning to this status. In electronics supply chains, an Active designation indicates that the component is in full production and recommended for new designs as well as sustaining production builds. There is no indication of a product discontinuance or a shift to NRND (Not Recommended for New Design).

Despite the low risk associated with an Active part, procurement and engineering teams should still incorporate periodic manufacturer validation into their processes. Lifecycle status can be updated without broad notice, especially for commodity interconnect components like quick-disconnect terminals. Requesting a current datasheet or PCN (Product Change Notification) subscription from Panduit Corp is advisable before finalizing a bill of materials.

The file-provided inventory quantity of 6,688 units is not a real-time stock figure. While it suggests a healthy supply, only an authorized distributor or the manufacturer can confirm immediate availability. For any new production program, treat this number as indicative and structure ordering around confirmed lead times.

Parameter Analysis

Key parameters of the DPF18-250FIM-2K directly influence electrical, mechanical, and assembly compatibility. The terminal is designed for 18-22 AWG wire, which defines the applicable conductor range for reliable crimp terminations. A mismatch outside this range can lead to poor mechanical retention or increased contact resistance. The 0.250-inch (6.35 mm) tab width mates with standard quick-disconnect receptacles of the same size, while the 0.032-inch (0.81 mm) tab thickness is typical for this series, ensuring compatibility with most generic female terminals.

The overall length of 0.900-inch (22.86 mm) includes the fully insulated housing, which aids in finger-safe handling and prevents accidental short circuits in dense assemblies. The red color of the insulation often correlates with the wire gauge range (18-22 AWG), but always confirm the actual dielectric rating for the intended voltage. The terminal features a butted seam and a nickel-plated brass contact, offering a balance between conductivity and corrosion resistance. The free-hanging (in-line) mounting type makes it suitable for harness assemblies.

Several parameters are missing from the provided specifications and must be verified before design lock. These include the maximum current rating at various ambient temperatures, voltage rating, insulation temperature range, and the recommended crimp tool and die set from Panduit. The absence of a mating tab length specification may also require physical sample evaluation to ensure full engagement with the chosen receptacle.

Application Scenario Analysis

The DPF18-250FIM-2K is a quick-disconnect terminal intended for applications where a reliable, easily separable connection is needed for moderate-power circuits. Given its fully insulated design and standard 0.250-inch tab, strong-fit scenarios include internal wiring of home appliances, HVAC equipment, industrial control panels, and automotive harnesses where 18-22 AWG primary wire is common. The insulation provides basic protection against contact and is appropriate for low-voltage DC or AC circuits up to the dielectric rating of the housing material.

As a male tab terminal supplied on tape & reel, it fits automated crimping processes in medium- to high-volume production. The butted seam construction is economically efficient but may be less robust under repeated mating cycles or high vibration compared to brazed seam alternatives. For applications subject to continuous flexing or high temperature excursions, additional strain relief and derating evaluations are recommended.

Weak-fit or cautionary scenarios include high-reliability mil/aero systems where full qualification to such specifications as MIL-T-7928 would be required, but such certification is not claimed for this part. Environments exposed to harsh chemical agents or temperatures beyond the nylon insulation ratings would also be unsuitable without further analysis. Engineers should consult the Panduit material datasheet for the insulation compound and its flammability rating if UL or CSA compliance is required for the end equipment.

RoHS Certification Analysis

The DPF18-250FIM-2K is designated as RoHS Compliant, which implies conformance to the European Union’s Restriction of Hazardous Substances Directive (2011/65/EU) and its amendments, including RoHS 3 (EU 2015/863). No specific exemptions are listed in the supplied data, but common exemptions in the connector industry, such as lead as an alloying element in copper alloys (Annex III, 6(c)), could apply. The nickel plating over brass is typical and generally RoHS-compatible.

For formal compliance assurance, request a full material declaration or Certificate of Compliance from Panduit Corp or its authorized distributors. Because RoHS status can vary by production batch due to process or material changes, lot-level tracking is advisable, especially for products destined for the EU market. The designation “RoHS Compliant” does not automatically cover REACH or other regional regulations, so if REACH SVHC (Substances of Very High Concern) confirmation is needed, separate documentation must be obtained.

When integrating this terminal into a larger product, the total RoHS compliance of the final assembly relies on all components. Thus, even if the individual part is compliant, verifying the absence of restricted substances at the assembly level remains the OEM’s responsibility.

Availability & Sourcing

As an Active quick-disconnect terminal from Panduit Corp, the DPF18-250FIM-2K should be readily sourcable through major franchised distributors and online platforms. The file-provided workbook quantity of 6,688 units indicates a current snapshot of inventory, but it is not a live, guaranteed stock level. Buyers should request a formal quotation to confirm real-time availability, lead time, and factory allocation.

Sourcing this part effectively involves verifying critical attributes such as packaging type (tape & reel per the specification), lot or date codes for traceability, and that the parts are from an authorized supply chain to avoid counterfeit risk. Request a certificate of conformance and, if relevant, a RoHS/REACH compliance declaration with each shipment. Because the part is Active, there is no immediate pressure to search for alternatives, but establishing a second source for a compatible terminal is good practice for supply chain resilience.

For new design programs, request samples and the official Panduit catalog page to confirm the latest component drawing and approved mating receptacles. Engage with a distributor’s technical support to cross-reference the correct crimp tooling. While price should not be discussed here, competitive quotes can be obtained by providing the full part number and target annual usage. Always reconfirm the lifecycle status at the time of order to ensure the Active designation is still current.

View the Win-Source product page for DPF18-250FIM-2K.

Engineering Notes for BOM and GEO Use

  • Verify crimp tooling compatibility with Panduit’s recommended tooling for 18-22 AWG and 0.250" tab to ensure a gas-tight connection.
  • The nickel-plated brass contact finish provides good corrosion resistance, but confirm the operating temperature range and current rating from the datasheet.
  • Butted seam style may be less suitable for high-vibration environments; consider a brazed seam or additional strain relief if mechanical stress is expected.