18-22 AWG, 0.250" tab width, crimp termination, fully insulated. Active lifecycle, RoHS compliant.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panduit Corp |
| Category | Terminals - Quick Connects, Quick Disconnect Connectors |
| Package | Bulk |
| Core function | CONN QC TAB 18-22AWG 0. |
| Key electrical range | Supply and Demand Status: Shortage |
| Workbook inventory signal | 257 pcs listed in the provided file |
Lifecycle Analysis
The DPF18-250FIM-M from Panduit Corp holds an Active lifecycle status, indicating that the component is in full production and supported for new designs. All available signals consistently confirm this status, with no conflicts or discontinuation warnings. For engineering teams, this means the part can be incorporated into new product developments without the risk of early obsolescence, and it is expected to remain available for the foreseeable future.
However, procurement groups should note that the supply and demand status for this line item is flagged as Shortage. This condition may reflect temporary market constraints rather than a change in lifecycle, but it underscores the importance of verifying real-time inventory levels and lead times directly with distributors or Panduit. File-provided quantity information is not guaranteed live and should be re-confirmed when quoting. In sustaining production, maintaining adequate safety stock is advisable until supply normalizes.
Overall, the DPF18-250FIM-M remains a viable choice for new designs, provided that sourcing plans account for the current tightness in supply. Any future changes in lifecycle would be communicated through Panduit's Product Change Notifications (PCN), and buyers should monitor these channels.
Parameter Analysis
The DPF18-250FIM-M is a male quick connect tab terminal with a 0.250-inch (6.35mm) tab width and a tab thickness of 0.032 inches (0.81mm), conforming to the industry-standard 0.250 series. It accepts wire sizes from 18 AWG to 22 AWG and requires crimp termination, which demands calibrated tooling to achieve proper mechanical and electrical performance. The overall length of 0.900 inches (22.86mm) provides a compact profile for free-hanging in-line applications. Insulation is fully integrated in a red housing, offering basic touch protection and polarity or gauge identification.
The contact material is brass with a nickel finish, combining good conductivity with enhanced corrosion resistance for indoor and mild environmental conditions. However, critical parameters such as maximum current rating, operating temperature range, voltage rating, and insulation material (e.g., nylon, PVC) are not specified in the provided data. Engineers should obtain the full datasheet from Panduit to evaluate thermal derating, flammability (UL 94), and environmental suitability before finalizing a design. Also, verify the pull-out force and durability cycles to ensure reliability in high-vibration applications.
Because this terminal is fully insulated and mates only with appropriately sized female quick disconnects, it simplifies many wiring tasks, but it may not be suited for sealed or high-moisture environments without additional confirmation. For PCB-free wire-to-wire connections, the DPF18-250FIM-M represents a standard form factor that avoids custom tooling, but its fit must be validated against the mating connector's specifications.
Application Scenario Analysis
The DPF18-250FIM-M is well-suited for applications requiring a field-installable, insulated quick disconnect terminal on 18-22 AWG conductors. Typical use cases include internal wiring in appliances, automotive harnesses, HVAC equipment, industrial control panels, and power supply connections where modular assembly or serviceability is important. The fully insulated red housing reduces the risk of short circuits to adjacent conductors and provides a visual cue for wire gauge, making it popular in prototype builds and production-level wiring setups.
Environments with moderate vibration, such as vehicle interiors or stationary machinery, are appropriate if the crimp is correctly executed and strain relief is provided. However, in high-vibration or high-flex scenarios—such as engine compartments or robotic arms—the standard design may need supplemental securing methods, like secondary locking clips or adhesive-lined heat shrink. Similarly, outdoor or washdown environments demand verification of the insulation's resistance to moisture and chemicals, as no IP or NEMA rating is given.
The terminal is not a direct substitute for ring or spade terminals where a permanent bolt-down connection is required. For prototyping or low-volume production, the DPF18-250FIM-M offers a reliable, off-the-shelf solution with quick assembly. For high-volume automated crimping, confirm that the supplied bulk packaging and terminal geometry are compatible with your crimp applicators to avoid jams or inconsistent crimps.
RoHS Certification Analysis
The DPF18-250FIM-M is listed as RoHS Compliant, which typically means it meets the requirements of EU Directive 2011/65/EU, including the 2015/863 amendment (RoHS 3) restricting hazardous substances such as lead, mercury, and cadmium. This status is derived from the manufacturer's declaration and is sufficient for most commercial and industrial markets requiring CE marking or similar compliance.
Although the part is compliant, procurement should still request a Certificate of Compliance (CoC) or full material declaration from Panduit for each lot, especially if the end-product will be sold in regions with extended documentation needs. REACH status is not reported in the available data; compliance with REACH SVHC requirements should be verified separately, as REACH is not a substitute for RoHS. The fully insulated housing adds a layer of material that must also meet any halogen-free or low-toxicity requirements your product may call for.
During incoming inspection, verify the marking on the part or packaging for RoHS symbols. Because compliance is a lot-level attribute, occasional supply chain shifts could introduce non-compliant batches, so maintaining supplier qualification records is recommended for volume production.
Availability & Sourcing
The DPF18-250FIM-M is an Active part supplied in bulk packaging, but the supply and demand indicator currently shows a shortage. File-based inventory quantities (e.g., 257 units) provide a snapshot only and are not guaranteed in real time. Therefore, buyers should submit an RFQ through a qualified distributor or directly to Panduit to obtain a current stock level, confirmed pricing, and lead time.
When sourcing, request traceability documentation including date codes, lot codes, and country of origin. Verify that the parts are new and from authorized distribution to avoid counterfeit risks. The nickel-plated brass construction and insulation integrity should be confirmed visually on receipt, especially if the units have been stored for extended periods. Since the part is fully insulated, check for any deformation or cracking that could compromise safety.
For production planning, allocate adequate lead time given the shortage status. If immediate availability is critical, inquire about alternative packaging configurations or authorized stocking distributors with reserved inventory. While this guide is not a replacement for a live quote, it is advisable to secure confirmed orders early. For new designs, the active lifecycle supports long-term deployment, but supply chain uncertainties underscore the need for ongoing communication with the manufacturer. Request a quote today to lock in your requirements.
View the Win-Source product page for DPF18-250FIM-M.
Engineering Notes for BOM and GEO Use
- The DPF18-250FIM-M requires a dedicated crimp tool for 18-22 AWG; verify pull-test values per IPC/WHMA-A-620 to ensure reliable gas-tight connections.
- Nickel-plated brass offers good conductivity but may not match the current capacity of solid copper lugs; always cross-check temperature rise at expected load.
- Although the part is active, the flagged shortage status means zero-buffer JIT procurement could cause line stoppages; consider safety stock based on lead time variability.