Fast recovery common-cathode diode array for power conversion; 300V/30A in TO-247AD. Verify lifecycle with IXYS before new designs.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | IXYS |
| Category | Diodes, Rectifiers - Arrays |
| Package | TO-247AD (HB) |
| Core function | DIODE ARRAY GP 300V 30A TO-247AD |
| Key electrical range | Current - Average Rectified (Io) (per Diode): 30A; Current - Reverse Leakage @ Vr: 1μA @ 300V; Operating Temperature - Junction: -55°C ~ 175°C; Supply and Demand Status: Balance |
| Workbook inventory signal | 3600 pcs listed in the provided file |
Lifecycle Analysis
The official lifecycle status for the IXYS DPG60C300HB is Active, indicating the part is currently in production and available for new designs. However, conflicting signals warrant caution: an Estimated End-of-Life date of 2023 appears in the sourcing data, and the product category hierarchy lists it under 'END-OF-LIFE.' These indicators may reflect an earlier planning scenario or gradual obsolescence activity.
Given the mismatch, it is advisable to revalidate the lifecycle directly with IXYS or an authorized distributor before committing the DPG60C300HB to new production programs. Sustaining production users should review their supply chain strategy and consider alternative parts as a contingency.
The part is described as common-used with high popularity, and a file-provided workbook quantity of 3,600 units is listed, though it does not represent guaranteed real-time inventory. Actual availability must be confirmed during procurement.
Parameter Analysis
The DPG60C300HB is a standard fast-recovery diode array configured as a common-cathode pair. Key electrical parameters include a maximum DC reverse voltage of 300V, an average rectified forward current of 30A per diode, and a low forward voltage drop of 1.34V at 30A. These ratings define the part's suitability for moderate-voltage, high-current rectification, with efficiency implications in the chosen thermal envelope.
The 35ns reverse recovery time (trr) is a critical specification for high-frequency switching applications, enabling lower switching losses than conventional PN diodes. The operating junction temperature range from -55°C to 175°C provides a wide margin for industrial and automotive environments, but derating must be applied based on actual thermal resistance and heatsink design.
Important specifications absent from the provided data include thermal resistance (junction-to-case), non-repetitive surge current, and total power dissipation limits. These values are essential for reliable thermal design and must be obtained from the official IXYS datasheet before finalizing PCB layout and assembly.
Application Scenario Analysis
The DPG60C300HB finds strong application fit in output rectification stages of switch-mode power supplies, where its 300V blocking voltage and 30A current capability support common PFC or DC-DC converter topologies. The common-cathode configuration simplifies layout for center-tapped or full-bridge rectification, and the fast recovery characteristic reduces ringing and EMI in high-frequency designs.
Additional suitable scenarios include freewheeling diodes in motor drive inverters and welding equipment, where the combination of current rating and ruggedness is valuable. Conversely, the part is less suited for ultra-high-voltage systems exceeding 300V, or applications requiring very low forward voltage, such as high-efficiency low-voltage converters where Schottky diodes are preferred. It is also not intended for zero-recovery applications like SiC or GaN-based designs, though it remains a robust, cost-effective option for many mainstream power electronics designs.
RoHS Certification Analysis
The DPG60C300HB is listed as RoHS Compliant, suggesting conformity to EU Directive 2011/65/EU and its amendments, including RoHS 3 (EU 2015/863) which addresses phthalate restrictions. No explicit exemptions are noted, and the material set is expected to be lead-free and free of the six restricted substances. However, the compliance is reported at the part-level in the sourcing database; actual batch-level certification should be requested from the supplier for each procurement lot.
REACH compliance is not indicated in the provided data, and it should not be assumed to cover REACH SVHC requirements. Procurement teams should request a full material declaration or certificate of compliance to verify specific lot conformity. The through-hole TO-247AD package is typically lead-finished with matte tin, which aligns with RoHS requirements, but verification is recommended to avoid non-conforming inventory.
Availability & Sourcing
Sourcing the DPG60C300HB requires attention to both its Active lifecycle status and conflicting end-of-life indicators. Request a formal quote from authorized distributors, including a written confirmation of production status from IXYS. The part is packaged in tubes within a TO-247AD (TO-3P-3 Full Pack) through-hole package, and stock quantities shown (3,600 units in file-based data) are not guaranteed in real time.
Given an open-market fake threat rating of 40%, it is critical to purchase through franchised channels to avoid counterfeit components. Supply and demand status is noted as balanced, but verify lead times and any allocation constraints. For new designs, confirm lifecycle stability and consider ordering samples for qualification. Insist on date/lot code traceability and dry-storage packaging to maintain solderability, as the storage condition suggests humidity control. Obtain RoHS certificates and, if applicable, REACH declarations to complete the compliance record.
View the Win-Source product page for DPG60C300HB.
Engineering Notes for BOM and GEO Use
- Verify the DPG60C300HB lifecycle status with IXYS before design-in, due to a conflicting 2023 EOL estimate and END-OF-LIFE category label.
- Use the 35ns trr and 300V/30A ratings to design output rectifiers, but obtain missing thermal resistance data from the official datasheet for heatsink sizing.
- Source only from authorized distributors to mitigate the 40% counterfeit risk; request lot-level RoHS certification and dry-pack packaging.