400V 60A fast recovery single diode, TO-247 through-hole package, active lifecycle, RoHS compliant, HiPerFRED™ series.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | IXYS |
| Category | Diodes, Rectifiers - Single |
| Package | TO-247 |
| Core function | DIODE STANDARD 400V 60A TO247 |
| Key electrical range | Supply and Demand Status: Limited |
| Workbook inventory signal | 5500 pcs listed in the provided file |
Lifecycle Analysis
The DPG60I400HA from IXYS is in active production with a low risk of discontinuation. This status is confirmed by the manufacturer’s public lifecycle data, which shows no plan for obsoletion. For design engineers, Active status means the part can be included in new designs and long-term sustaining production programs without immediate concern for last-time buys or end-of-life transitions.
Despite the low-risk designation, it is prudent to periodically monitor the lifecycle status directly from IXYS, especially for programs with multi-year deployment. Supply chain groups should also note that lifecycle information from component databases may lag manufacturer changes, so cross-checking with official sources is advised when high volumes are involved.
A file-provided inventory figure shows 5500 units available, but this quantity is not a live stock guarantee. Buyers should treat it as an indicator of market presence rather than real-time on-hand, and always verify availability during the request-for-quote process.
Parameter Analysis
The DPG60I400HA’s key parameters center on its 400V maximum repetitive reverse voltage (Vr) and 60A average forward current (Io), making it suited for mid-power rectification tasks. Its fast recovery characteristic (≤500ns) and specified reverse recovery time (trr) of 45ns are critical for reducing switching losses in higher-frequency circuits. The typical forward voltage drop (Vf) of 1.47V at 60A directly impacts conduction losses and thermal design.
Operating junction temperature spans -55°C to 175°C, providing wide thermal margin for industrial environments. The TO-247 through-hole package enables effective heatsink mounting, though thermal resistance values (RθJC) are not provided in the summary data and must be obtained from the full datasheet to calculate temperature rise accurately.
Missing but important verification parameters include junction-to-case thermal resistance, maximum surge current (Ifsm), and typical junction capacitance. Engineers should consult IXYS’s official datasheet for these derating-critical specifications before committing to a layout or thermal solution.
Application Scenario Analysis
The DPG60I400HA is a strong fit for output rectification in AC-DC and DC-DC power supplies, freewheeling diodes in motor drives, and snubber or clamp circuits. Its fast recovery speed minimizes reverse recovery losses, making it suitable for switched-mode power supplies (SMPS) operating at moderate frequencies. The 400V rating allows margin in 230V AC line rectified applications.
It can also serve in reverse-battery protection and OR-ing configurations where low forward voltage helps manage power dissipation. However, for circuits with very high operating frequency (e.g., >200kHz) or extremely low forward voltage requirements, a more specialized Schottky or silicon carbide diode might be preferable. The through-hole TO-247 package suits designs with active cooling and large heatsinks, but may be a poor fit for compact surface-mount layouts.
Buyers should note that the Diode, Rectifiers - Single category encompasses general-purpose use, and this part is not qualified for radiation-hardened, aerospace, or automotive-grade reliability unless specifically rated by IXYS.
RoHS Certification Analysis
The DPG60I400HA is designated RoHS Compliant, meaning it conforms to the EU Restriction of Hazardous Substances directive. While the exact revision is not stated in the supplied data, RoHS compliance generally covers EU 2015/863 (RoHS 3) unless otherwise noted. No exemptions are reported for this part.
In addition to RoHS, a REACH unaffected status confirms that no substances of very high concern (SVHC) are present above the threshold, though REACH compliance does not substitute for RoHS. Component-level documentation such as standalone certificates should be requested for batch-specific verification.
The MSL rating is Level 1 (Unlimited), indicating no special moisture barrier packaging is needed before soldering, simplifying storage and handling. Nevertheless, compliance data should be reconfirmed with the manufacturer or distributor, especially when parts are sourced through non-authorized channels.
Availability & Sourcing
As an active IXYS product, the DPG60I400HA is available through authorized distributors with standard RFQ-based procurement. A file-provided warehouse quantity of 5500 pieces suggests market presence, but real-time inventory must be verified at time of quote. The estimated production lead time of 44 weeks is substantial; design-in plans should account for this when calculating buffer stock and safety lead times.
Supply and demand status is listed as limited, and the reported open-market fake threat rate is 57%, indicating a high risk of counterfeit parts when sourcing from unauthorized channels. Buyers should prioritize franchised distributors and request full traceability documentation, including date/lot codes and compliance certificates.
Packaging is tube with 30 units per tube, suited for small-to-medium production runs. Given the active lifecycle, the recommended sourcing strategy is to request a current quote for pricing and availability, verify lifecylce status directly with IXYS or authorized partners, and ensure RoHS/REACH certifications accompany each shipment. Do not rely solely on file-provided quantities for production planning.
View the Win-Source product page for DPG60I400HA.
Engineering Notes for BOM and GEO Use
- Verify thermal resistance (RθJC) and maximum surge current from the official DPG60I400HA datasheet before finalizing power dissipation and SOA margins.
- The reported 44-week production lead time and 57% fake threat rate demand procurement from authorized IXYS distributors with full traceability.
- MSL Level 1 allows unlimited floor life, but inspect tube packaging integrity and plan for proper through-hole mounting and heatsink attachment in layout.