DPP120-48-1 TDK-Lambda Power Supply Specs & Sourcing Guide

DPP120-48-1 TDK-Lambda Americas Inc. product image

AC/DC DIN Rail Power Supply, 48V 120W | Not For New Designs

Quick Engineering Summary

FieldValue
ManufacturerTDK-Lambda Americas Inc.
CategoryIndustrial, DIN Rail Power Supplies
PackageBulk
Core functionAC/DC DIN RAIL SUPPLY 48V 120W
Key electrical rangeAC Voltage - Input: 85 ~ 132 VAC, 176 ~ 264 VAC; Current - Output (Max): 2.5A; Input Type: AC; Number of Outputs: 1
Workbook inventory signal124 pcs listed in the provided file

Lifecycle Analysis

The DPP120-48-1 presents conflicting lifecycle information. The Lifecycle Status field is listed as Active, but the Product Status is explicitly Not For New Designs. For procurement and engineering purposes, the more conservative Product Status should govern, meaning this part is effectively NRND (Not Recommended for New Designs). Engineers must not use the DPP120-48-1 in new product development without direct confirmation from TDK-Lambda.

Existing designs using the DPP120-48-1 should evaluate long-term availability. The file-provided inventory quantity of 124 units is a snapshot and not a guarantee of real-time stock. Given the shortage status, it is wise to secure inventory for current production needs and initiate a migration plan to an alternative power supply. A formal last-time buy notice or product change notification from the manufacturer should be obtained to avoid supply interruption.

Parameter Analysis

Key specifications of the DPP120-48-1 include a selectable AC input range (85-132 VAC and 176-264 VAC), 48V output at 2.5A delivering 120W, 87% efficiency, 3 kV input-to-output isolation, and an operating temperature of -40°C to +71°C with derating. These parameters establish basic fit for industrial DIN rail systems. The adjustable output voltage and load-sharing feature enable flexibility in parallel configurations, though the specific adjustment range is not detailed.

Important missing parameters that must be verified from the official datasheet include output ripple and noise, line and load regulation, hold-up time, inrush current, protection features (overvoltage, overcurrent, short-circuit), and MTBF. The CE marking suggests basic safety compliance, but detailed agency reports are not provided. The 87% efficiency demands adequate thermal design; operating at elevated temperatures will require derating per the manufacturer's curve.

Application Scenario Analysis

The DPP120-48-1 is designed for industrial DIN rail mounting and is rated for ITE (Commercial) applications. Its 48V output serves standard 48V bus systems in factory automation, process control, and building management cabinets. The wide input range supports both 115V and 230V nominal AC mains, making it suitable for global deployment. The load-sharing capability allows multiple units to be paralleled for redundancy or higher current, a common requirement in critical automation systems.

Due to its 'Not For New Designs' status, new projects should avoid this part. The limited approvals (CE only) and absence of medical or safety certifications restrict its use in medical, railway, or hazardous area equipment. For high-reliability applications, lack of MTBF data and detailed qualification test reports may be a concern. For existing platforms, the DPP120-48-1 can remain in sustaining production, but a formal migration path is recommended.

RoHS Certification Analysis

The DPP120-48-1 is marked as RoHS Compliant, meeting EU hazardous substance restrictions. However, the source data does not specify the exact directive or amendment (e.g., EU 2015/863), so it is prudent to verify RoHS 3 compliance, especially for products containing phthalates. While many TDK-Lambda power supplies are RoHS compliant, family-level declarations may not cover every manufacturing lot.

No REACH, China RoHS, or MSL information is provided. For EU-bound equipment, a REACH SVHC statement should be requested. Additionally, if soldering processes require moisture sensitivity classification, the MSL rating must be obtained from the manufacturer. Compliance documentation should be requested on a batch-by-batch basis to ensure ongoing conformity during the product's lifecycle, especially given its NRND status.

Availability & Sourcing

Sourcing the DPP120-48-1 requires careful attention to its Not For New Designs status. File-provided stock shows 124 units, but this figure is not a real-time guarantee. The supply and demand status indicates a shortage, so immediate availability may be constrained. Buyers should request a current quote from authorized TDK-Lambda distributors and inquire about lead times, minimum order quantities, and the possibility of last-time buys. Packaging is listed as Bulk; confirm with the supplier whether this refers to individual boxes or standard industrial packaging.

For engineers maintaining existing equipment, it is advisable to verify lot codes, date codes, and RoHS compliance certificates upon receipt. Since the part is transitioning away from new designs, securing enough inventory for the anticipated production lifetime of existing products is critical. Additionally, ask the manufacturer for a product change notification (PCN) and EOL roadmap to plan timely requalification of an alternative supply.

View the Win-Source product page for DPP120-48-1.

Engineering Notes for BOM and GEO Use

  • This part is designated 'Not For New Designs'; confirm lifecycle with TDK-Lambda before committing.
  • Verify missing datasheet parameters such as ripple/noise, hold-up time, and protection features for your design.
  • Request lot-specific RoHS and REACH compliance documents, especially for EU applications.